{"title":"Hybrid microassembly combining laser die transfer and capillary self-alignment","authors":"Bo Chang, Mikko Koverola, Z. Ge, Quan Zhou","doi":"10.1109/MARSS.2017.8001904","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001904","url":null,"abstract":"Laser die transfer technique provides an efficient solution for fast transportation of microchips in microassembly. Capillary self-alignment is able to achieve parallel and high-accuracy alignment of microchips on receptor sites. In this paper, we propose a new hybrid microassembly strategy, which combines laser die transfer and capillary self-alignment techniques. The laser die transfer technique was used for the coarse positioning of microchips and the capillary self-assembly technique was applied to achieve high-accuracy alignment. A low-power and low-cost laser device was investigated in laser die transfer process and hydrophilic/superhydrophobic patterned surfaces were fabricated and served as receptor sites. Microscopic droplets were introduced as the media for capillary self-alignment. The results show that the microchip can be selectively released and self-aligned with the corresponding receptor site. The proposed method could be useful for high-throughput, high-accuracy and fully-automatic assembly in construction of miniature devices.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121480356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Maura Power, C. Seneci, A. Thompson, Guang-Zhong Yang
{"title":"Modelling and characterization of a compliant tethered microgripper for microsurgical applications","authors":"Maura Power, C. Seneci, A. Thompson, Guang-Zhong Yang","doi":"10.1109/MARSS.2017.8001946","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001946","url":null,"abstract":"The development of microscale surgical tools could pave the way for truly minimally invasive microsurgical procedures. This work demonstrates the application of direct laser writing (DLW) using two-photon polymerization (TPP), a rapid prototyping microfabrication technique, to create a tethered, passively actuated three-dimensional gripper with potential applications in microbiopsy. A microgripper design was devised, modelled and optimized. The gripper was then fabricated and characterized for validation of the theoretical model. The results demonstrate that modelling the behavior of compliant microtools provides a useful approximation for the observed trends and, thus, can be utilized in the design of TPP tools. Future work on the incorporation of viscoelastic material into the model will further improve agreement between the predicted and experimental performance.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"59 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115129016","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hao Li, Sang Seon Lee, Eunpyo Choi, Sunghoon Cho, Jong-Oh Park
{"title":"Development of direct patterning and visualization system for fabrication of hydrogel microstructure","authors":"Hao Li, Sang Seon Lee, Eunpyo Choi, Sunghoon Cho, Jong-Oh Park","doi":"10.1109/MARSS.2017.8001942","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001942","url":null,"abstract":"In this study, we developed a direct patterning system based on infinity-corrected optics for light-induced fabrication of hydrogel microstructures, while still visualizing the fabrication process in real time by integrating the objective lens and red LED system. The optical projection system for reducing the size of patterns from film mask to desired substrate was optimized through the theoretical calculation and the numerical simulation. Then the optic system was integrated with macro and micro manipulation stage for direct patterning of hydrogel. To demonstrate the proposed patterning and visualizing system, the UV-curable hydrogel was patterned in micro-scale and observed simultaneously.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132910635","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Seonggun Joe, Dongkyu Lee, Byungkyu Kim, Byungjeon Kang, Jong-Oh Park
{"title":"Design and dynamics analysis of a compact tattooing mechanism for a capsule endoscope","authors":"Seonggun Joe, Dongkyu Lee, Byungkyu Kim, Byungjeon Kang, Jong-Oh Park","doi":"10.1109/MARSS.2017.8001899","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001899","url":null,"abstract":"Capsule endoscopes (CEs) have been highlighted as a next generation diagnostic device for the digestive organs (i.e. the stomach, small bowel and colon). Although CE imaging functions and control techniques have been continuously studied, CEs cannot completely replace conventional wire-based endoscopes because current commercial CEs only have diagnosis functions. To extend the range of applications for CEs, functional modules (e.g. biopsy, polyp removing and drug delivery modules) that can be installed in CEs have also attracted continuous attention. Therefore, in this paper, a simple and compact tattooing mechanism is proposed to carry out endoscopic tattooing, an important function of conventional endoscopes. The proposed tattooing mechanism is sufficiently compact to be applicable to conventional CEs. It ejects vertically and then withdraws the tattooing needle after the ink injection is completed. The insertion depth is kept within 3 mm to accommodate the properties of the stomach. Lastly, a dynamics analysis using a commercial code is carried out to determine a workable model considering the tattooing fluid effect.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115874225","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Multi-particle acoustic manipulation on a Chladni plate","authors":"K. Latifi, Harri Wijaya, Quan Zhou","doi":"10.1109/MARSS.2017.8001920","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001920","url":null,"abstract":"Controlling the motion of multiple miniature objects independently and simultaneously is a grand challenge in microrobotics. In this paper, we report our recent achievements in acoustic manipulation that can control the motion of multiple objects simultaneously and independently on a centrally actuated vibrating plate. By employing spatially highly nonlinear excitation fields on the plate, we can control the motion of multiple objects with relaxed properties. The paper reports the modelling of the excitation fields, open-loop control based on pre-calculated control sequence, and closed loop control using model predictive control (MPC) and linear programming methods. The experimental results show that with appropriate planning, object motion on vibrating plate is sufficiently predictable to be controlled even in open-loop. The experimental results with closed-loop control show that the methods allow various applications including trajectory following, particle assembling, and droplet merging. Despite the reported method is based on acoustic manipulation on a Chladni plate, the method can be extended to other energy fields as soon as they are spatially highly nonlinear and such nonlinearity can be excited.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130133909","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Stereo-image rectification for dense 3D reconstruction in scanning electron microscope","authors":"A. Kudryavtsev, S. Dembélé, N. Piat","doi":"10.1109/MARSS.2017.8001905","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001905","url":null,"abstract":"Stereo rectification is a crucial step for a number of computer vision problems and in particular for dense 3D reconstruction which is a very powerful characterization tool for microscopic objects. Rectification simplifies and speeds up the correspondence search in a pair of images: the search space is reduced to a horizontal line. It is mainly developed for perspective camera model: a projective transformation is found and applied to both images. This paper addresses the rectification problem for an image pair obtained with Scanning Electron Microscope (SEM). In this case, image formation is described by a parallel projection, indeed perspective effects can be neglected because of the low value of the sample size over working distance ratio. Based on these hypotheses, a robust estimation of the fundamental matrix, that describes the geometry of the image pair, is proposed. It filters out up to 50% of outliers in a feature correspondence set. Then, the matrix is used to develop a rectification solution: the problem is reduced to two rotations about the optical axis of the camera. The solution is accurate and does not require any calibration of SEM. It is validated with two image pairs from two different field effect SEMs.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134080139","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Palagi, A. Mark, K. Melde, T. Qiu, H. Zeng, C. Parmeggiani, D. Martella, D. Wiersma, P. Fischer
{"title":"Locomotion of light-driven soft microrobots through a hydrogel via local melting","authors":"S. Palagi, A. Mark, K. Melde, T. Qiu, H. Zeng, C. Parmeggiani, D. Martella, D. Wiersma, P. Fischer","doi":"10.1109/MARSS.2017.8001916","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001916","url":null,"abstract":"Soft mobile microrobots whose deformation can be directly controlled by an external field can adapt to move in different environments. This is the case for the light-driven microrobots based on liquid-crystal elastomers (LCEs). Here we show that the soft microrobots can move through an agarose hydrogel by means of light-controlled travelling-wave motions. This is achieved by exploiting the inherent rise of the LCE temperature above the melting temperature of the agarose gel, which facilitates penetration of the microrobot through the hydrogel. The locomotion performance is investigated as a function of the travelling-wave parameters, showing that effective propulsion can be obtained by adapting the generated motion to the specific environmental conditions.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124560447","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design and optimization of a compact, large amplification XY flexure-mechanism","authors":"Joshua Pinskier, B. Shirinzadeh, L. Clark","doi":"10.1109/MARSS.2017.8001909","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001909","url":null,"abstract":"This article presents the design methodology, optimization, and computational verification of a compact, high-gain planar XY flexure mechanism. The presented mechanism consists of a decoupled XY mechanism, and a modified Scott-Russel mechanism, which maintain linear XY motion, and amplify the input piezoelectric actuator (PEA) displacement respectively. Each mechanism offers the potential for use in isolation. When operated together, the combined mechanism is capable of nanometer scale precision and millimeter scale range in a vacuum-compatible design. The presented mechanism could therefore be used in micro-assembly operations including those performed in electron microscopes. The design methodology and mechanism models are presented, with the selected design computationally optimized and analyzed. By using a broad design space, and minimizing assumptions, the optimized mechanism produces workspace of approximately 930 × 940 μm2 from 15 μm of input displacement.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"14 3","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114109347","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Recent progress in laser assisted digital selective nanomaterial processing","authors":"S. Ko","doi":"10.1109/MARSS.2017.8001908","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001908","url":null,"abstract":"Laser is a very unique and useful tool for materials processing with the various parameter choice range. The main mechanism of typical laser processes is photo-induced thermal reaction that generates confined temperature field at a desired position with high controllability. The laser-induced selective temperature rise enables selective chemical reaction for synthesis of nanomaterials in various environment including both gas and liquid environment as well as photophysical processing of nanomaterials through melting or vaporization, represented by laser sintering and ablation processes. In this review, recent progresses in the selective digital laser processing for nanomaterial process and synthesis on various heat sensitive substrate. This laser based process can achieve novel device fabrication which have never been possible with conventional photolithography based electronics fabrication process.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"813 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116182257","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sambeeta Das, E. Steager, K. Stebe, Vijay R. Kumar
{"title":"Simultaneous control of spherical microrobots using catalytic and magnetic actuation","authors":"Sambeeta Das, E. Steager, K. Stebe, Vijay R. Kumar","doi":"10.1109/MARSS.2017.8001924","DOIUrl":"https://doi.org/10.1109/MARSS.2017.8001924","url":null,"abstract":"The ability to steer multiple microrobots in different directions in the same workplace has been an ongoing challenge for the field. In this paper we present a novel method of controlling multiple microrobots in the same workplace by combining their magnetic actuation with catalytic motion. We achieve motion differentiation through the use of paramagnetic microrobots which assume different magnetizations in the same field. This is combined with a catalytic cap which regulates the direction of motion of the microrobot. Independent motion and steering control is demonstrated for groups of one, two and three microrobots. Furthermore, the robustness of the system is demonstrated by attachment and detachment of two microrobots using a common magnetic field. This proposed method could be used for wide ranging applications in the fields of engineering, biology and medicine. Especially in the field of cargo and drug delivery, the ability to steer individual particles to user defined locations is very important and, in this paper, we demonstrate that an individual microrobot can be reliably steered to a user defined location.","PeriodicalId":255334,"journal":{"name":"2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125700932","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}