[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium最新文献

筛选
英文 中文
A comparison among different front-end input versions of a medical record system 病案系统不同前端输入版本的比较
Kuo-Lane Chen, M. Evens, D. Trace, F. Naeymi-Rad
{"title":"A comparison among different front-end input versions of a medical record system","authors":"Kuo-Lane Chen, M. Evens, D. Trace, F. Naeymi-Rad","doi":"10.1109/CBMS.1993.262967","DOIUrl":"https://doi.org/10.1109/CBMS.1993.262967","url":null,"abstract":"This paper describes a series of experiments to test whether there are significant differences between several different versions of the intelligent medical record-entry system (IMR-E). As the costs of including color graphics decrease, the use of multimedia technologies is becoming an important issue. The development of pen computers provides a whole new range of possibilities for data input. The authors are planning to measure the effects of color, machine speed, and the use of a mouse or a pen computer on input time and user satisfaction when the system is used to input patient data by physicians and medical students.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125858698","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Developing an advanced 'tool' for the clinician; using industrial design and interface design together to bring technology into the hand of the user 为临床医生开发先进的“工具”;将工业设计和界面设计结合起来,将技术带到用户手中
Tighe Belden, W. L. Sembrowich, D. W. Deetz, Frank A. Solomon
{"title":"Developing an advanced 'tool' for the clinician; using industrial design and interface design together to bring technology into the hand of the user","authors":"Tighe Belden, W. L. Sembrowich, D. W. Deetz, Frank A. Solomon","doi":"10.1109/CBMS.1993.263014","DOIUrl":"https://doi.org/10.1109/CBMS.1993.263014","url":null,"abstract":"A discussion is given on the unique, user-centered design process applied in developing a portable blood gas analysis device. The designers using this process actively and continually drew upon the knowledge and experiences of people who will ultimately use the product. The outcome is a 'tool' that enables people in medical settings to perform a task previously unavailable to them, on-site real-time blood gas analysis. As a tool, the device needed to provide the functions in the most efficient and effective manner. To understand what product interface would be needed to accomplish this, potential end-users were involved throughout the design process. The paper focuses on this user-centered development process that literally brought the device into the hands of clinicians.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129696413","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A new multiresolution predictive scheme for lossless compression of medical images 一种新的医学图像无损压缩多分辨率预测方案
M. Das, C. C. Li, S. Burgett
{"title":"A new multiresolution predictive scheme for lossless compression of medical images","authors":"M. Das, C. C. Li, S. Burgett","doi":"10.1109/CBMS.1993.262994","DOIUrl":"https://doi.org/10.1109/CBMS.1993.262994","url":null,"abstract":"This paper introduces a new multiresolution predictive scheme for lossless compression of medical images. The proposed scheme consists of three successive steps: namely, multiresolution decomposition, hierarchical interpolation and predictive coding using two-dimensional multiplicative autoregressive models. The performance of the proposed technique is compared with three alternative techniques: namely, difference pyramid (DP), reduced difference pyramid (RDP) and hierarchical interpolation (HINT) method. The experimental results indicate that the proposed scheme achieves significantly higher compression compared to the other techniques considered.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132468523","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Establishing a software engineering process group in a medical device company 在医疗器械公司建立软件工程过程组
Bruce Zemlin
{"title":"Establishing a software engineering process group in a medical device company","authors":"Bruce Zemlin","doi":"10.1109/CBMS.1993.263007","DOIUrl":"https://doi.org/10.1109/CBMS.1993.263007","url":null,"abstract":"Establishing a software engineering process group, SEPG, in a medical device company requires careful planning and organizing to succeed. The author discusses how to proceed after executive management says 'we must be at the best process performance level possible, tell us what to do'. He also includes major problems in establishing a SEPG and how to prevent or correct them. A SEPG's mission is to, 'provide leadership in advancing the state of the practice of software engineering to improve the quality of systems that depend on software'. The main method the SEPG uses is technology transition, 'the process of organizing, executing, and supporting activities that lead to the adoption and institutionalization of new technologies, methods, or approaches such that they become a routine part of doing business'.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117032761","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A software analysis technique for quantifying reliability in high-risk medical devices 一种量化高风险医疗器械可靠性的软件分析技术
J. Voas, K. Miller, J. Payne
{"title":"A software analysis technique for quantifying reliability in high-risk medical devices","authors":"J. Voas, K. Miller, J. Payne","doi":"10.1109/CBMS.1993.262989","DOIUrl":"https://doi.org/10.1109/CBMS.1993.262989","url":null,"abstract":"The authors present a software engineering technique called sensitivity analysis that aims at producing software that is less likely to hide faults. When sensitivity analysis indicates that faults are not likely to hide from testing, they can more comfortably rely on the results of testing. Sensitivity analysis has been automated, and preliminary results from the automated analysis suggest that the technique will have significant advantages for the development, validation, and regulation of medical devices.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"186 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128186107","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Electronics development for the Utah electrohydraulic total artificial heart 犹他州电液全人工心脏的电子学发展
G. Bearnson, S. R. Krivoy, R. D. Jarmin, J. R. Fratto, P. Khanwilkar, K. Crump, K. D. Smith
{"title":"Electronics development for the Utah electrohydraulic total artificial heart","authors":"G. Bearnson, S. R. Krivoy, R. D. Jarmin, J. R. Fratto, P. Khanwilkar, K. Crump, K. D. Smith","doi":"10.1109/CBMS.1993.263011","DOIUrl":"https://doi.org/10.1109/CBMS.1993.263011","url":null,"abstract":"Recent developments in the electronics and embedded software of the electrohydraulic total artificial heart under development at the University of Utah are discussed. These include development of a new brushless DC motor commutator, implementation of the implanted electronics in hybrids, integration of a transcutaneous energy transfer (TET) and telemetry system into the controller, and packaging of a short-term, totally implantable system. A discussion of future plans for the totally implantable system is given.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126354735","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Traditional software development's effects on safety 传统软件开发对安全性的影响
L. Gowen, M. Y. Yap
{"title":"Traditional software development's effects on safety","authors":"L. Gowen, M. Y. Yap","doi":"10.1109/CBMS.1993.262990","DOIUrl":"https://doi.org/10.1109/CBMS.1993.262990","url":null,"abstract":"Faults in a system can result in catastrophic consequences such as death, injury or environmental harm. For example, the Therac 25 incident killed two patients and severely injured a third patient due to a software error. The Therac 25 is a computer-controlled therapeutic radiation machine. Governmental, industrial, and academic researchers are searching for new ways to prevent and detect hazardous faults when developing and certifying safety-critical software systems. To determine the effects of these new techniques, this paper discusses an experiment where developers in the control group followed a traditional methodology while the experimental group followed a modified methodology, which consisted of the control group's methodology along with certain safety-specific methods and guidelines for the following life-cycle phases: specification, design, and verification. The results showed that the experimental group had fewer latent safety-critical faults than the control group.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"90 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132541186","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Computerized cardiopulmonary perfusion-a six year overview 计算机心肺灌注-六年概述
Molly I. Tisdell, Charles F. Jerabek
{"title":"Computerized cardiopulmonary perfusion-a six year overview","authors":"Molly I. Tisdell, Charles F. Jerabek","doi":"10.1109/CBMS.1993.262978","DOIUrl":"https://doi.org/10.1109/CBMS.1993.262978","url":null,"abstract":"A computer system has been developed for use as an information manager during cardiac surgery. This system interfaces with the patient monitor, heart-lung machine, blood gas machines, computer keyboard, and thermistor probes. The system provides continuous data collection, comprehensive visual display, and storage to a protected ASCII file. Real time data is used to update calculated parameters during surgery. Quality assurance methods include checklists, alarms, graphics capabilities, and software programs which display adherence to protocol. Statistical analysis of objective data may be completed during retrospective studies. Countless upgrades have been applied to the hardware and software, allowing the system to adapt well to the fast pace of medical and technological advances in the operating room.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"131 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115617720","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
FDA and the regulation of medical software FDA和医疗软件的监管
Paul T. H. Kim
{"title":"FDA and the regulation of medical software","authors":"Paul T. H. Kim","doi":"10.1109/CBMS.1993.262999","DOIUrl":"https://doi.org/10.1109/CBMS.1993.262999","url":null,"abstract":"This paper traces the development of the Food and Drug Administration's (FDA) regulation of computer software, as discrete products with medical applications as well as components of regulated medical devices. The earliest Agency deliberations of software are summarized, as are the Agency's broad policy priorities and the concerns of developers, medical industries, and user communities over the potential scope and consequences of FDA regulation.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"102 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121473024","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
A new method for estimating dimensions and 3-D reconstruction of coronary arterial trees from biplane angiograms 一种新的冠状动脉树三维重建方法
T. Kayikçioglu, S. Mitra
{"title":"A new method for estimating dimensions and 3-D reconstruction of coronary arterial trees from biplane angiograms","authors":"T. Kayikçioglu, S. Mitra","doi":"10.1109/CBMS.1993.262974","DOIUrl":"https://doi.org/10.1109/CBMS.1993.262974","url":null,"abstract":"The coronary arteries may be represented and visualized efficiently by a generalized cylinder (GC) model with elliptical cross-sections. By using this model and utilizing quadratic expression of an ellipse, the intensity distribution of an ellipse in any image plane, which is perpendicular to the plane of the arterial cross-section, is computed. A nonlinear parametric model for observed intensity distribution of an arterial cross-section is applied to estimate not only cross-sectional areas but also parameters of the ellipse which are essential in 3-D reconstruction of an arterial segment. This model takes into account background intensity, noise and blurring. Performance of this model has been tested on computer-generated and actual data for various background types and noise values and compared to those of other methods for estimating arterial dimensions. The computed cross-sectional areas from our model for computer-generated as well as actual data demonstrate much less variability than those reported in recent literature. 3-D reconstruction of arterial segments from actual biplane angiograms is presented.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122034818","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信