{"title":"Building a Low-Cost Climate Chamber to Test Lithium Ion Batteries under Site Conditions","authors":"Thomas Youngleson, S. Rajakaruna","doi":"10.1109/AUPEC52110.2021.9597802","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597802","url":null,"abstract":"With the increasing reliance on renewable energy sources to meet future sustainability goals, the need for new models and testing techniques are required to test and forecast battery storage capacity under different climatic conditions. The paper explores the feasibility of building a low-cost climate enclosure for the acquisition of experimental data on the discharge properties of lithium-ion batteries under different climatic conditions. The experimental results obtained using the built climate enclosure showed stability and reliability in maintaining both temperature and humidity. These results help to provide insight into future testing methods and the ability to tune existing battery models for real operating conditions and age.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114632899","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. Sakthivelnathan, A. Arefi, C. Lund, A. Mehrizi‐Sani, David Stephens
{"title":"Marginal Cost of Reliability Improvement for Standalone Microgrids","authors":"N. Sakthivelnathan, A. Arefi, C. Lund, A. Mehrizi‐Sani, David Stephens","doi":"10.1109/AUPEC52110.2021.9597729","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597729","url":null,"abstract":"The marginal cost of reliability improvement (MCRI) is a very useful measure to compare the cost-effectiveness of various standalone microgrid (SMG) systems. This measure helps in decision making on reliability level and imports and exports between SMGs. The MCRI can elucidate how a SMG system is going to deal with the change of reliability requirements by customers and energy traders. This paper proposes an MCRI evaluation algorithm for a microgrid (MG) over its 25-year lifespan. A case study is evaluated, which consists of renewable energy resources (RES) and a battery energy storage system (BESS) as reliability improvement (RI) alternatives. Two sensitivity analysis study are performed to answer the following research questions: What if is the cost of energy resources changes? and What if demand response (DR) is included as an alternative to RI. Furthermore, whether maximum reliability can be achieved with 100% renewable generating resources is also evaluated. The Monte Carlo Simulation (MCS) method is used to model the equipment failure. The linear regression approach is used to create an equation for loss of load reduction (LOLR), for the addition of resource mix as a function of LOLR and for the addition of individual RI alternatives. A Matlab optimization tool is used to find the MCRI.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121548449","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluating of Frequency Response Time Characteristics of Large Scale Energy Storage Systems in High Renewable Energy Penetrated Power Systems","authors":"G.A.M.Tirantha Bandara, S. Rajakaruna, A. Ghosh","doi":"10.1109/AUPEC52110.2021.9597738","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597738","url":null,"abstract":"Frequency stability of most modern power systems has significantly deteriorated in the recent past due to the rapid growth of inverter interfaced renewable energy generation systems. Energy storage systems are being identified as a promising remedy to overcome such adverse effects. This paper investigates the dynamic response of a power system that has high renewable energy penetration and is also compensated by a large-scale energy storage system. The system dynamic response with a ternary pumped hydro storage, a liquid air storage and a battery energy storage system are studied and compared in this paper. Dynamic models for each storage system and their time domain responses are evaluated using a modified IEEE 14 bus test system. The paper produces an accurate methodology to simplify dynamic models and study the frequency response characteristics of large-scale ESS. Results show that the BESS has very fast frequency response compared to other two large-scale ESS. Fast and slow responsive hybrid model containing large-scale ESS may provide promising solution for storage-based grid ancillary services.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125342592","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
G. Revati, Palak M., U. Suryawanshi, A. Sheikh, S. Bhil
{"title":"Load Profile Prediction in Smart Building using Data Driven Approaches","authors":"G. Revati, Palak M., U. Suryawanshi, A. Sheikh, S. Bhil","doi":"10.1109/AUPEC52110.2021.9597702","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597702","url":null,"abstract":"With the emergence of the smart grid and smart city trends, smart buildings are gaining attention. Energy management is a key component of a smart building management system, and it necessitates precise forecasting of the building's electrical energy usage profile. In view of this, the paper focuses on the analysis of a data-driven approach for predicting the electricity consumption of a smart building in a model-free environment. For predicting the load profile the dynamic mode decomposition (DMD) and deep learning models such as recurrent neural network (RNN), long short term memory (LSTM), bidirectional LSTM (BiLSTM), and gated recurrent unit (GRU) model are considered in this paper. The paper also proposes the development of a hybrid model using the best features of RNN and BiLSTM. A comparative study is carried out for analyzing the performance of different data-driven approaches and for that various test scenarios were conducted to evaluate the prediction accuracy. Finally, from the prediction results, it can be claimed that the deep learning models especially the proposed hybrid model outperform other deep learning methods as well as DMD due to the consideration of hyperparameters.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131017204","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Floating Solar PV and Hydropower in Australia: Feasibility, Future Investigations and Challenges","authors":"Sofia Mahmood, S. Deilami, S. Taghizadeh","doi":"10.1109/AUPEC52110.2021.9597714","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597714","url":null,"abstract":"As floating solar photovoltaic (FPV) technology has become increasingly popular due to its many benefits, the potential of combining an FPV and hydropower plant (HPP) has also come to light. Many studies have been conducted covering its potential globally and locally, while only two of these hybrid plants currently exist in the world. No local studies have been conducted in Australia to analyse the potential of a hybrid floating photovoltaic (FPV) and hydropower plant (HPP), as such, this paper conducts a literature review in order to gain an understanding of the benefits and requirements of a hybrid plant. HPP locations in Australia where a hybrid plant may be established are also proposed, and a small analysis is conducted on their potential.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130368644","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Inertia Shortfall and the Capability of Inverter-based Generation to provide Inertial Response: A Review for Australian Power System","authors":"Thanh Tung To, M. H. Haque","doi":"10.1109/AUPEC52110.2021.9597760","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597760","url":null,"abstract":"This paper discusses the status quo of the Australian power system revolving around the frequency stability problem yielded by inertia shortfall. Corresponding actions carried out by related governing bodies in the Australian power sector are also presented. Moreover, a short overview on the techniques to enable the capability of inverter-based renewable resources (IBRS) in contributing virtual inertia has also been conducted, focusing on wind power generators without energy storage and solar photovoltaics (PVs) paired with battery storage systems. It is found that the adjusted operational objective function with suitable supplementary inertial control loop(s) is economically beneficial for both the IBRS plants and the Australian power system considering the situation in Australia and the global obligatory trend in renewable energy development. The study of this paper could facilitate further investigations regarding system inertia calculation as well as changes in frequency control practices in power networks with high IBRS penetration levels.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128875208","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Solution of an Optimal Reactive Power Dispatch problem: An application of Modified Ant Lion Optimizer","authors":"S. Chaitanya, B. Rao, R. A. Bakkiyaraj","doi":"10.1109/AUPEC52110.2021.9597756","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597756","url":null,"abstract":"This paper proposes Optimal Reactive Power Dispatch (ORPD) using Modified Ant Lion Optimizer (MALO). ORPD which is a subsection of optimal power flow is considered as an important optimization problem in the sector of electrical power systems. With the help of ORPD, the operators have control over the voltage limits to retrench the true power losses in transmission lines. Formulation of ORPD is performed by considering the output voltages of generators, tap changing transformers and switchable capacitor devices. MALO is recently developed metaheuristic optimization technique. This technique is applied on the IEEE 30 bus systems by considering different cases like minimization of active power loss and achievement of good voltage profile. The system performance is improved with MALO and the losses are comparatively low with DE, PSO, GSA and MFO methods.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122150692","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Tohid Rahimi, E. Pashajavid, M. Fallah, J. Pou, A. Arefi, K. Loo
{"title":"A Family of Fault-tolerant Single-phase 15-level Inverters for UPS Applications","authors":"Tohid Rahimi, E. Pashajavid, M. Fallah, J. Pou, A. Arefi, K. Loo","doi":"10.1109/AUPEC52110.2021.9597763","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597763","url":null,"abstract":"This paper presents a family of fault-tolerant single-phase inverter topology for uninterruptible power supply (UPS) systems. The core structure is a 15-level inverter, consisting of two unidirectional switches, eight bidirectional switches, and six DC voltage sources. The proposed topology can facilitate realizing fault-tolerant multi-module inverters. If one of the power sources or semiconductor devices fails in one of the modules, the remaining modules can alternatively deliver all the expected voltage levels. Thus, this efficiently eliminates the possibility of UPS system failure for critical applications. The proposed topology is compared with the conventional 15-level inverters regarding the number of voltage sources, switches, and drivers to prove its advantages. The gate signals for the switches are produced employing the fundamental frequency switching technique. Further, the efficacy and performance of the proposed topology are supported with the simulation and experimental validations.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126104196","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Johnson, Abhinandan Pathak, Shantanu Arya, Sagar Dipesh Dahanuwala, Prathamesh Gachhi, T. Moger
{"title":"Case Studies of Event Detection for Indian Power System using Signal Processing Methods","authors":"T. Johnson, Abhinandan Pathak, Shantanu Arya, Sagar Dipesh Dahanuwala, Prathamesh Gachhi, T. Moger","doi":"10.1109/AUPEC52110.2021.9597799","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597799","url":null,"abstract":"With the deployment of phasor measurement units (PMU) and wide area measurement system (WAMS), it is feasible to have an insight into the real-time events occurring in power systems based on measured PMU data. Any critical disturbance occurring in a power system is noted as an Event. The analysis carried out in this paper are based on PMU data inferences derived using various signal processing methods like Fast Fourier Transform, Yule-Walker Spectral Analysis, Matrix Pencil and Min-Max. The results of each of these methods have been described and an intersection of results from two or more methods are finally identified as Events. The results have been compiled on two different data sets: one for the Northern Region of Indian Power Grid and another for entire Indian power system. The data with respect to Northern Region was collected on 20th May 2020, during the cyclone Amphan, which caused many disruptions in electric power network. The second data was gathered from 30 stations all over India during an electromechanical oscillation fault.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126696516","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yan Li, Jiapeng Li, Runbin Cao, Shudan Wang, F. Peng, Yujun Li, Wei-huang Huang, Yonghui Liu
{"title":"Non-Unit Protection Algorithm for MTDC Systems Based on Transient Variance of Current","authors":"Yan Li, Jiapeng Li, Runbin Cao, Shudan Wang, F. Peng, Yujun Li, Wei-huang Huang, Yonghui Liu","doi":"10.1109/AUPEC52110.2021.9597709","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597709","url":null,"abstract":"Fast detection and isolation of the fault line within the “capacitor discharging stage” after direct current (DC) faults has become a major challenge for multi-terminal DC (MTDC) systems comprised of voltage source converters (VSCs). Existing protection schemes rely on tedious numerical simulations to determine the threshold value. To tackle that, this paper first defines a time-domain index for fault transient signals, namely, the transient variance. The equivalence between the transient value and the high-frequency energy is then demonstrated. Accordingly, a novel protection algorithm for MTDC systems is proposed, which utilizes the transient variance to extract high-frequency components of the measured current signal and is capable of identifying the fault line fast with no need of communication. Furthermore, the error between transient fault current with distributed parameters line model and that with the lumped parameters model has been assessed as well. Numerous simulations have been conducted in PSCAD/EMTDC, which attest that the proposed algorithm can exhibit good performance under various fault locations with the proper selection of time window length.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"161 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129071304","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}