Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices最新文献

筛选
英文 中文
The Reproducibility of a Proposed Standard Fatigue Test for Cardiac Device Leads 心脏装置引线标准疲劳试验的可重复性
Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices Pub Date : 2019-06-01 DOI: 10.1002/HTTPS://DOI.ORG/10.1520/STP161620180033
T. Quinn, J. Splett, J. D. Mccolskey, J. Dawson, David J. Smith, Adam Himes, D. Cooke
{"title":"The Reproducibility of a Proposed Standard Fatigue Test for Cardiac Device Leads","authors":"T. Quinn, J. Splett, J. D. Mccolskey, J. Dawson, David J. Smith, Adam Himes, D. Cooke","doi":"10.1002/HTTPS://DOI.ORG/10.1520/STP161620180033","DOIUrl":"https://doi.org/10.1002/HTTPS://DOI.ORG/10.1520/STP161620180033","url":null,"abstract":"The Transvenous Cardiac Leads Working Group of the Cardiac Rhythm Management Devices Committee of the Association for the Advancement of Medical Instrumentation is developing a fatigue performance standard for cardiac device leads. The proposed standard would calculate a figure-of-merit (FOM) that is based on a life prediction using a Bayesian framework. The framework uses distributions for bending fatigue strength, patient age, patient activity level, and in vivo bending. The benchtop fatigue testing portion of the standard is based on the unsupported bending of the lead at multiple alternating curvature levels to generate fatigue fracture data in low-cycle and high-cycle regimes. To estimate the interlaboratory reproducibility of the benchtop testing methodology, a lead mock-up was constructed from a bifilar MP35N coil in a thin-walled polyurethane tube. Four laboratories each tested 48 specimens and produced fatigue life curves based on the results. To compare the data, the FOM Manuscript received May 2, 2018; accepted for publication July 24, 2018. National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80305, USA T. P. Q. http://orcid.org/0000-0001-7731-0128 Medtronic, 8200 Coral Sea St. NE, Mounds View, MN 55112, USA A. H. http://orcid.org/0000-0002-68834840 Boston Scientific, 4100 Hamline Ave. North, St. Paul, MN 55112, USA ASTM Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices, on May 22–23, 2018 in San Diego, CA, USA This work is not subject to copyright law. ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. FOURTH SYMPOSIUM ON FATIGUE AND FRACTURE OF METALLIC MEDICAL MATERIALS AND DEVICES 85 STP 1616, 2019 / available online at www.astm.org / doi: 10.1520/STP161620180033 that is proposed for the standard was calculated using initial in vivo curvature data of a well-performing lead. The reproducibility standard deviation of the FOM across the four laboratories was 0.17 % of the grand mean.","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127703768","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
A Statistically Rigorous Fatigue Strength Analysis Approach Applied to Medical Devices 一种应用于医疗器械的统计严谨疲劳强度分析方法
W. Falk
{"title":"A Statistically Rigorous Fatigue Strength Analysis Approach Applied to Medical Devices","authors":"W. Falk","doi":"10.1520/STP161620180034","DOIUrl":"https://doi.org/10.1520/STP161620180034","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121276701","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Application of Classical Fatigue and Fatigue-to-Fracture Techniques for Very-High-Cycle Life Qualification of Cardiac Devices 经典疲劳和疲劳-断裂技术在心脏装置高循环寿命鉴定中的应用
P. Schmidt, William Krams, H. Cao, T. Jenkins
{"title":"Application of Classical Fatigue and Fatigue-to-Fracture Techniques for Very-High-Cycle Life Qualification of Cardiac Devices","authors":"P. Schmidt, William Krams, H. Cao, T. Jenkins","doi":"10.1520/STP161620180122","DOIUrl":"https://doi.org/10.1520/STP161620180122","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126401624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Effect of Hot Isostatic Pressing on Fatigue Properties and Particle Shedding in Additively Manufactured Ti-6Al-4V-ELI 热等静压对增材制造Ti-6Al-4V-ELI疲劳性能和颗粒脱落的影响
J. Bonini, H. Leung, Krista Biggs, Kevin Knight, E. Rios
{"title":"Effect of Hot Isostatic Pressing on Fatigue Properties and Particle Shedding in Additively Manufactured Ti-6Al-4V-ELI","authors":"J. Bonini, H. Leung, Krista Biggs, Kevin Knight, E. Rios","doi":"10.1520/STP161620180031","DOIUrl":"https://doi.org/10.1520/STP161620180031","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116435091","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fracture and Fatigue Properties of Cobalt Chrome Alloys Used For Medical Implants 医用植入物用钴铬合金的断裂和疲劳性能
K. Perry, J. Trowbridge
{"title":"Fracture and Fatigue Properties of Cobalt Chrome Alloys Used For Medical Implants","authors":"K. Perry, J. Trowbridge","doi":"10.1520/STP161620180036","DOIUrl":"https://doi.org/10.1520/STP161620180036","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130014109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Finite Element Framework for Fatigue Performance Assessment of Superelastic Nitinol Used in Medical Devices 医疗器械用超弹性镍钛诺疲劳性能评价的有限元框架
S. Tripathy, M. Wu, H. Cao
{"title":"Finite Element Framework for Fatigue Performance Assessment of Superelastic Nitinol Used in Medical Devices","authors":"S. Tripathy, M. Wu, H. Cao","doi":"10.1520/STP161620180039","DOIUrl":"https://doi.org/10.1520/STP161620180039","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123610802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A New Approach for Fatigue-to-Fracture Testing of Coronary Stents 冠状动脉支架疲劳-断裂测试新方法
M. Frotscher, Martin Jackstien, Chris Conti, E. Strope, J. Conti
{"title":"A New Approach for Fatigue-to-Fracture Testing of Coronary Stents","authors":"M. Frotscher, Martin Jackstien, Chris Conti, E. Strope, J. Conti","doi":"10.1520/STP161620180037","DOIUrl":"https://doi.org/10.1520/STP161620180037","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"176 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120956532","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Fatigue Reliability Analysis Framework for Medical Devices Based on a Probabilistic Finite Element Approach 基于概率有限元法的医疗器械疲劳可靠性分析框架
V. Shanmugam, Tianwen Zhao, William Krams, A. Joshi, H. Cao, P. Schmidt
{"title":"Fatigue Reliability Analysis Framework for Medical Devices Based on a Probabilistic Finite Element Approach","authors":"V. Shanmugam, Tianwen Zhao, William Krams, A. Joshi, H. Cao, P. Schmidt","doi":"10.1520/STP161620180038","DOIUrl":"https://doi.org/10.1520/STP161620180038","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133185218","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Effect of Variable Amplitude Loading in Nitinol Fatigue 变幅加载对镍钛诺疲劳的影响
B. Choules, Alexandra Lewis, B. Gulker, J. M. Metcalf, J. Kelley
{"title":"Effect of Variable Amplitude Loading in Nitinol Fatigue","authors":"B. Choules, Alexandra Lewis, B. Gulker, J. M. Metcalf, J. Kelley","doi":"10.1520/STP161620180035","DOIUrl":"https://doi.org/10.1520/STP161620180035","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128416043","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Quest for Fatigue-Resistant Nitinol for Medical Implants 医用植入物抗疲劳镍钛诺的探索
A. Pelton, S. Pelton, Tim Jörn, J. Ulmer, D. Niedermaier, K. Plaskonka, W. LePage, P. Saffari, M. Mitchell
{"title":"The Quest for Fatigue-Resistant Nitinol for Medical Implants","authors":"A. Pelton, S. Pelton, Tim Jörn, J. Ulmer, D. Niedermaier, K. Plaskonka, W. LePage, P. Saffari, M. Mitchell","doi":"10.1520/STP161620180041","DOIUrl":"https://doi.org/10.1520/STP161620180041","url":null,"abstract":"","PeriodicalId":240447,"journal":{"name":"Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126499624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×