{"title":"Torque Ripples Minimization Strategies of Switched Reluctance Motor - A Review","authors":"Reyad Abdel-Fadil, Fahad Al-Amyal, L. Számel","doi":"10.1109/CANDO-EPE47959.2019.9110960","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9110960","url":null,"abstract":"The Switched Reluctance Motor (SRM) is a prominence type of electric motor because it has many advantages such as simple structure, consistency and durability, low cost, wide speed range and prominent fault-tolerant ability. This benefits of SRM are faced by the existence of torque ripples because of the highly nonlinear electromagnetic characteristics, and complex control due to nonlinear behavior and also the controller needs rotor position information. The existence of the torque ripple leads to the generation of annoying noise and undesired vibration during the operation, the torque ripple can be reduced by improving the magnetic design of the motor and/or by using advanced electronic control strategies. In this paper, various control strategies used to reduce torque ripples are explained and outlined, the operation mechanism, benefits, drawbacks, and suitable application of each control technique are introduced.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"85 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117240360","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Multiphysics Analysis of Automotive PMaSynRM","authors":"Attila Nyitrai, G. Szabó, S. Horváth, I. Vajda","doi":"10.1109/CANDO-EPE47959.2019.9111009","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9111009","url":null,"abstract":"The purpose of a Multiphysics Analysis is the modeling of complex physical systems where different kinds of physical effects act simultaneously. We would like to predict the behavior of a machine with the least number of neglected effects. Nowadays more Finite Element Method (FEM) based simulation software are readily available to study the physics of an electrical machine. Although, there are no standardized solutions that would fit every kind of electric motor analysis. In this paper we will present a method how to go through step-by-step on the different physical phenomena of an electrical machine and therefore analyze the different design and working aspects.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122121169","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluation of Thermally Aged Nuclear Power Plant Power Cables Based on Electrical Condition Monitoring and Regression Analysis","authors":"Ramy S. A. Afia, E. Mustafa, Tamus Zoltán Ádám","doi":"10.1109/CANDO-EPE47959.2019.9110962","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9110962","url":null,"abstract":"The safe operation of nuclear power plants relies on many components such as nuclear reactors, heat exchangers, concrete structure and thousands of kilometers of instrumentation, control and low voltage power cables. The severe operating conditions in the nuclear power plants which characterized by high radiation levels and elevated temperature affect the insulation integrity of these cables, therefore, the condition monitoring of these cables has a particular concern. In this research, low voltage nuclear power plant power cables were thermally accelerated aged for different aging periods to simulate different service periods. The effect of the thermal aging on these cables was investigated using the extended voltage response method where two parameters were measured, the slope of decay and return voltages. The results showed that the voltage decay slope increased with increasing the aging period while the return voltage slope decreased. The estimated values of the return voltage slope were calculated using the parameters obtained from the regression analysis and this showed a strong correlation with the aging and polarization processes.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128780166","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Accelerated Thermal Aging of the Liquid Dielectrics","authors":"Peter Havran, R. Cimbala, P. Bartko","doi":"10.1109/CANDO-EPE47959.2019.9110999","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9110999","url":null,"abstract":"The essence of this paper is to investigate and compare current characteristics of thermally degraded liquid dielectric using impedance spectroscopy. The theoretical part explains electrophysical phenomena in dielectrics and characterization of the method of impedance spectroscopy in the frequency and time domain. The practical part takes into account the experiment, which is focused on the used sample of liquid dielectric, description of the measuring workplace and analysis of experimental results in the frequency and time domain.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133001155","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Brief Review of Transient Electromagnetic Immunity Testing","authors":"M. Buzdugan, H. Balan","doi":"10.1109/CANDO-EPE47959.2019.9111040","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9111040","url":null,"abstract":"The paper intends to be a brief review of the electromagnetic immunity of the equipment connected to the low voltage networks, against transient impulses, in compliance with the tests included in the specific standards IEC/EN 61000-4 and the related ones. Tests were performed in a lighting installation of an office building consisting in LED linear luminaires, constant current driven with adjustable output current. After the introductory part, the three following sections treat the immunity to electrostatic discharge, electrical fast transients and surge. Following the tests, it was found necessary to retrofit an additional EMI filter on the mains input of the luminaires.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123080638","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"CANDO-EPE 2019 Welcome from the General Chair","authors":"","doi":"10.1109/cando-epe47959.2019.9111055","DOIUrl":"https://doi.org/10.1109/cando-epe47959.2019.9111055","url":null,"abstract":"","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132088292","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of Electromagnetic Field in 110 kV Substation","authors":"Dušan Medved’, M. Pavlík, J. Zbojovský","doi":"10.1109/CANDO-EPE47959.2019.9111057","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9111057","url":null,"abstract":"This article deals with the investigation of electric and magnetic field distribution of an electric 110 kV substation. The chosen quantities, that were investigated were electric intensity E and magnetic induction B. Simulations, realized in ANSYS, were performed at three selected heights of 0.3 m; 1 m and 1.8 m above the ground, that consisted of 168 measuring points along the selected part of the power-line. The simulation results were analysed and compared with the action values set out in Decree 534/2007 Coll. and 209/2016 Coll.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133399622","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Review of Frequency Spectrum and Energy Consumption in 5G","authors":"Z. Temesvári","doi":"10.1109/CANDO-EPE47959.2019.9110996","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9110996","url":null,"abstract":"This article is a review of the challenges mobile service operators face regarding the growing needs of subscribers and the construction of mobile base stations in a given frequency situation. There is a summary about the key traffic trends and the previous frequency tender, but the next frequency auction is also investigated from a 5G point of view. The article also reviews the expected 5G frequency spectrum and performance and how it influences the deployment of base stations. The energy consumption of the base stations is examined in regards to the 5G networks energy efficiency. The paper furthermore assesses the potential changes in the main purpose and strategies of a mobile operator following the introduction of the future mobile network, the 5G","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"128 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130540974","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Vectors-based method to deduce neighboring cells in mobile networks","authors":"Iyad Khuder, Robret Bestak","doi":"10.1109/CANDO-EPE47959.2019.9111034","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9111034","url":null,"abstract":"This paper discusses the coverage in mobile networks, for which we propose a novel method to deduce neighboring cells, where the number of cells could be very large. The priority for this method is simplicity, so it can be easily implemented and executed in a short processing time, even for a large number of cells. Therefore, the proposed method uses a simple graphical representation of the cells by means of vectors to only maintain the cells’ size and orientation. Although the method is motivated by applications which are related to user-mobility in mobile networks, it might be useful in other applications, where the nearest neighbors search problem is involved, such as in computational geometry and pattern recognition in machine learning.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131126379","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Temperature Field Distribution Analysis of Electrical Contacts for High-current Equipment","authors":"Dušan Medved’","doi":"10.1109/CANDO-EPE47959.2019.9110966","DOIUrl":"https://doi.org/10.1109/CANDO-EPE47959.2019.9110966","url":null,"abstract":"This paper deals with the analysis of contacts for high-current equipment. The issue of electrical contacts is an area in which the tasks of solving material, mechanical, electrical and last, but not least, temperature relations describing the processes of electrical current transfer through contacts meet. Knowing the exact distribution of the temperature field of and around the electrical contacts allows manufacturers to select the right material, resize the shape, or adjust the conductive path so that the electrical contact does not overheat and perform the function of the re-switching element in the electrical circuit.","PeriodicalId":237429,"journal":{"name":"2019 International IEEE Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127771901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}