Ventilation, Illumination and Heat Gas Supply最新文献

筛选
英文 中文
An analysis of effectiveness of air heat pump operation dependent on change of external air temperature 外部空气温度变化对空气热泵运行效果的影响分析
Ventilation, Illumination and Heat Gas Supply Pub Date : 1900-01-01 DOI: 10.32347/2409-2606.2021.37.24-30
O. Shapoval, N.   Chepurna, M. Kirichenko
{"title":"An analysis of effectiveness of air heat pump operation dependent on change of external air temperature","authors":"O. Shapoval, N.   Chepurna, M. Kirichenko","doi":"10.32347/2409-2606.2021.37.24-30","DOIUrl":"https://doi.org/10.32347/2409-2606.2021.37.24-30","url":null,"abstract":"Currently, air-to-water heat pumps are more widely used, which due to the high coefficient of performance reduce energy consumption and negative impact on the environment. They decrease the dependency on costs of energy resources. The work is devoted to solving the urgent problem of improving the efficiency of air heat pumps at low temperature of outdoor air in winter. One of the main problems of an air heat pump is the reduction of productivity when the outdoor air temperature decreases in winter. In this paper, the effectiveness of LG Therma V air-to-water heat pump to provide apartments with heating and hot water supply was analyzed. The heat pump is reversive, which can cool or heat a heat carrier. A four-way valve swithes the coolant flows between air exchangers. On the basis of the obtained results, plots of effectivness of the heat pump dependent on outdoor air temperature are built. It is shown that the effectiveness of the heat pump significantly depends not only on the outside temperature but also on the water temperature at the outlet of the heat pump. The use of heat pumps with a high coefficient of performance can significantly reduce energy costs. The most effective are low-temperature heating systems, in which the water temperature does not exceed 45 °C. The example is floor heating, which requires very low temperature of the floor surface – up to 30 °C. At outdoor air temperature not less than milnus 7 °C the heat pump is effective at higher temperature off heat carrier at output – up to 55 °C. To provide the uninterrupted heat supply, an additional air heater is included. It covers heat load during defrosting and very low outdoor air temperature. On the basis of the conducted researches, the directions of the further experimental and field researches are planned.","PeriodicalId":23499,"journal":{"name":"Ventilation, Illumination and Heat Gas Supply","volume":"50 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75820090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信