{"title":"Electromagnetic vibration analysis of double redundancy permanent magnet synchronous motors in two modes","authors":"Chen Yiguang, Liao Guodong, Shen Yonghuan","doi":"10.1109/ITNEC.2017.8285058","DOIUrl":"https://doi.org/10.1109/ITNEC.2017.8285058","url":null,"abstract":"Double redundancy permanent magnet synchronous motor (DRPMSM) is used in the occasion which has higher reliability requirement. In the paper, the electromagnetic vibration of fractional-slot concentrated windings dual-redundancy permanent magnet synchronous motor of 10-pole/12-slot with low thermal coupling and non-electromagnetic coupling between windings in two modes which includes double-redundancy working and single-redundancy working, was investigated and simulated. Electromagnetic field and force, motor modal and electromagnetic vibration were researched in orders. The differences between them were analyzed. The results can offer guides for the structure design of DRPMSM.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130322640","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zhiyuan Cai, Xudong Wang, Yubo Yang, Xueshen Cui, H. Zhao
{"title":"Research on influence factor of system efficiency and power loss factor for DC power supply system of data center","authors":"Zhiyuan Cai, Xudong Wang, Yubo Yang, Xueshen Cui, H. Zhao","doi":"10.12783/DTEEES/PEEE2016/3785","DOIUrl":"https://doi.org/10.12783/DTEEES/PEEE2016/3785","url":null,"abstract":"This paper focus on energy efficiency comparison and analysis of different DC power distribution mode for large data center. First, several single-module DC power supply systems with different voltage level and power capacity are applied to substitute for UPS based AC distribution mode for a typical data center of high-tech park with many enterprises. Secondly, system efficiency, power supply loss factor(PLF) and power usage effectiveness(PUE) are used respectively to analyze and evaluate the energy efficiency of power supply system with IT equipment. Then a simulation model is developed with MATLAB/SIMULINK platform to compare the simulation results for different voltage level and capacity of battery supply. These results of energy saving analysis are quantified and shown with the calculation and analysis on system efficiency and power factor of PLF. Finally, the efficiency of a data center is measured for different power supply, the tested data is in agreement with the simulation.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"718 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116128579","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Synchronous frame control for voltage sag/swell compensator utilizing single-phase matrix converter","authors":"Kichiro Yamamoto, Sho Ehira, M. Ikeda","doi":"10.1541/IEEJJIA.6.353","DOIUrl":"https://doi.org/10.1541/IEEJJIA.6.353","url":null,"abstract":"n this paper, a synchronous frame control for a voltage sag/swell compensator utilizing single-phase matrix converter is proposed. First, the configuration of proposed system and its operation are described. Next, effects of the degree of voltage sag and load variation on the system stability is analyzed by transfer function. Finally, experimental waveforms for the system with proposed synchronous frame control are compared with those for the system with a stationary frame control. The results demonstrate that proposed synchronous frame control can suppress steady state error and pulsation by LC filter resonance as compared to the stationary frame control.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"170 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114463984","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Instantaneous vector control of four switch three phase inverter fed induction motor drive","authors":"Ufot Ufot Ekong, M. Inamori, M. Morimoto","doi":"10.1541/IEEJJIA.6.429","DOIUrl":"https://doi.org/10.1541/IEEJJIA.6.429","url":null,"abstract":"This paper proposes a transformation matrix to generate Pulse Width Modulation (PWM) signals for Four Switch Three Phase Inverter (FSTPI) using vector control. The feasibility of the control strategy is verified by proving the power invariance before and after the transformation. Simulation and experimental results have verified the validity and effectiveness of the proposed method to obtain instantaneous response in different operating conditions and provide fast speed response.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121959903","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of permanent magnet properties and arrangement on performance of IPMSMs for automotive applications","authors":"Yuki Shimizu, S. Morimoto, M. Sanada, Y. Inoue","doi":"10.1541/IEEJJIA.6.401","DOIUrl":"https://doi.org/10.1541/IEEJJIA.6.401","url":null,"abstract":"Interior permanent magnet synchronous motors (IPMSMs) are widely utilized as traction motors. The permanent magnets (PMs) used in IPMSMs are an important factor; thus, high-coercivity PMs with lesser rare-earth elements are in development. This paper investigates the performance of IPMSMs typically used in automotive applications that were modified to contain a novel magnet model (NMM). Rotor models with two PM arrangements, a V-shaped single-layered PM structure (Type 1V) and a double-layered PM structure (Type 2D), were considered in this study. This paper discusses the characteristics of the analysis models based on the results of two-dimensional finite element analysis. The maximum torques of Types 1V and 2D with the NMMs were approximately the same. In addition, the loss of Type 2D with the NMM was lower than that of Type 1V with the NMM at two evaluation points and under two driving schedules. Therefore, Type 2D was proved to be suitable for use with NMMs.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134409069","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Tatsuya Yamamoto, Y. Bu, T. Mizuno, Yutaka Yamaguchi, T. Kano
{"title":"Loss reduction of transformer for LLC resonant converter using a magnetoplated wire","authors":"Tatsuya Yamamoto, Y. Bu, T. Mizuno, Yutaka Yamaguchi, T. Kano","doi":"10.1541/IEEJJIA.7.43","DOIUrl":"https://doi.org/10.1541/IEEJJIA.7.43","url":null,"abstract":"To improve the power density of a switching power supply, we attempt to reduce the transformer loss using a magnetoplated wire (MPW). Contrary to using a copper wire, the use of an MPW allows for a reduction of the winding loss component due to the proximity effect. In particular, we investigate the 1-MHz LLC resonant converter using an MPW. A 4.5% decrease in the power loss is achieved, giving 29.4 W at 1 MHz and 1 kW.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"95 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133376855","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Extremum co-energy principle for analyzing AC current distribution in parallel-connected wires of high frequency power inductors","authors":"T. Shirakawa, G. Yamasaki, K. Umetani, E. Hiraki","doi":"10.1541/IEEJJIA.7.35","DOIUrl":"https://doi.org/10.1541/IEEJJIA.7.35","url":null,"abstract":"Inductor winding is often composed as parallel-connected wires to suppress the copper loss. However, in high frequency inductors, the proximity effect can cause concentrated AC current distribution, hindering suppression of the copper loss. Therefore, optimization of the physical inductor structure requires predicting the AC current distribution. Although simulators are commonly employed for predicting the AC current distribution, simple analytical methods are also required for effective design or invention of the inductor structure with less copper loss. The purpose of this paper is to propose a novel analysis method of the AC current distribution in parallel-connected wires of high frequency inductors. The proposed method is based on a novel insight that the AC current is distributed to give an extremum of the magnetic co-energy contributed by the AC flux and the AC current under the given total AC current. Experiments are presented in this paper to verify the proposed method.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117099185","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Characteristics analysis of claw-pole alternator for automobiles by nonlinear magnetic field decomposition for armature reaction","authors":"K. Yamazaki, Ren Suzuki, M. Nuka, M. Masegi","doi":"10.1541/IEEJJIA.6.362","DOIUrl":"https://doi.org/10.1541/IEEJJIA.6.362","url":null,"abstract":"In this study, we investigate the characteristics of claw-pole alternators for automobiles from both results of calculation and experiments. Nonlinear 3-D finite element analysis is employed to take the claw-pole shape into account. The calculated characteristics are compared with the experimental results in order to confirm the validity of the analysis. Then, the magnetic field is decomposed according to the field sources in order to understand the effect of armature reaction. It is clarified that the large armature reaction in the claw-pole alternator causes the saturation of electrical output and the increase in the harmonic losses in the machine.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"02 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130838525","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Fujita, T. Hirose, T. Ueda, H. Ishizuka, M. Okubo, K. Nagakura, T. Tokumasu
{"title":"Inter-strand circulating current analysis of end-region transposed coil of power generator using 3D multi-layer FEM","authors":"M. Fujita, T. Hirose, T. Ueda, H. Ishizuka, M. Okubo, K. Nagakura, T. Tokumasu","doi":"10.1541/IEEJJIA.6.449","DOIUrl":"https://doi.org/10.1541/IEEJJIA.6.449","url":null,"abstract":"Stator coils of large rotating machines are divided into strands which are transposed to reduce the inter-strand circulating current loss. To evaluate the effect of transposition, circulating current analysis is required but full 3D analysis is difficult because of the complicated configuration of the transposed coils. In this paper, magnetic field analysis model using 3D multi-layer finite element method is proposed to calculate the inter-strand circulating current in the stator coil with transposition in the coil end region especially with non-transposed region. Then circulating currents are analyzed considering the magnetic flux in the end region and some transposition patterns are compared.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131398555","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Ishikawa, Taiki Watanabe, Shota Mizuno, N. Kurita
{"title":"Effect of cleaning level on topology optimization of permanent magnet synchronous generator","authors":"T. Ishikawa, Taiki Watanabe, Shota Mizuno, N. Kurita","doi":"10.1541/IEEJJIA.6.416","DOIUrl":"https://doi.org/10.1541/IEEJJIA.6.416","url":null,"abstract":"We proposed a topology optimization method that incorporates the concept of cluster and cleaning method in Genetic algorithm (GA). This method can design a rotor structure from the empty space, which has high output power and less permanent magnet volume. In this paper, the effect of strength of the cleaning method on the obtained rotor structure is investigated. Using the optimal strength of the cleaning method, a PMSG is designed, which has higher output power characteristic with less permanent magnet volume than a Prius type generator.","PeriodicalId":224768,"journal":{"name":"2016 19th International Conference on Electrical Machines and Systems (ICEMS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125796575","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}