Biophotonics Australasia最新文献

筛选
英文 中文
High speed multiphoton imaging 高速多光子成像
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242951
Yongxiao Li, Anne Brustle, V. Gautam, I. Cockburn, C. Gillespie, K. Gaus, W. Lee
{"title":"High speed multiphoton imaging","authors":"Yongxiao Li, Anne Brustle, V. Gautam, I. Cockburn, C. Gillespie, K. Gaus, W. Lee","doi":"10.1117/12.2242951","DOIUrl":"https://doi.org/10.1117/12.2242951","url":null,"abstract":"Intravital multiphoton microscopy has emerged as a powerful technique to visualize cellular processes in-vivo. Real time processes revealed through live imaging provided many opportunities to capture cellular activities in living animals. The typical parameters that determine the performance of multiphoton microscopy are speed, field of view, 3D imaging and imaging depth; many of these are important to achieving data from in-vivo. Here, we provide a full exposition of the flexible polygon mirror based high speed laser scanning multiphoton imaging system, PCI-6110 card (National Instruments) and high speed analog frame grabber card (Matrox Solios eA/XA), which allows for rapid adjustments between frame rates i.e. 5 Hz to 50 Hz with 512 × 512 pixels. Furthermore, a motion correction algorithm is also used to mitigate motion artifacts. A customized control software called Pscan 1.0 is developed for the system. This is then followed by calibration of the imaging performance of the system and a series of quantitative in-vitro and in-vivo imaging in neuronal tissues and mice.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124000270","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Optofluidic technology for monitoring rotifer Brachionus calyciflorus responses to regular light pulses 光流体技术监测萼花臂轮虫对规则光脉冲的响应
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242879
R. Cartlidge, O. Campana, D. Nugegoda, D. Wlodkowic
{"title":"Optofluidic technology for monitoring rotifer Brachionus calyciflorus responses to regular light pulses","authors":"R. Cartlidge, O. Campana, D. Nugegoda, D. Wlodkowic","doi":"10.1117/12.2242879","DOIUrl":"https://doi.org/10.1117/12.2242879","url":null,"abstract":"Behavioural alterations can occur as a result of a toxicant exposure at concentrations significantly lower than lethal effects that are commonly measured in acute toxicity testing. The use of alternating light and dark photoperiods to test phototactic responses of aquatic invertebrates in the presence of environmental contaminants provides an attractive analytical avenue. Quantification of phototactic responses represents a sublethal endpoint that can be employed as an early warning signal. Despite the benefits associated with the assessment of these endpoints, there is currently a lack of automated and miniaturized bioanalytical technologies to implement the development of toxicity testing with small aquatic species. In this study we present a proof-of-concept microfluidic Lab-on-a-Chip (LOC) platform for the assessment of rotifer swimming behavior in the presence of the toxicant copper sulfate. The device was designed to assess impact of toxicants at sub-lethal concentrations on freshwater crustacean Brachionus calyciflorus, testing behavioral endpoints such as animal swimming distance, speed and acceleration. The LOC device presented in this work enabled straightforward caging of microscopic crustaceans as well as non-invasive analysis of rapidly swimming animals in a focal plane of a video-microscopy system. The chip-based technology was fabricated using a new photolithography method that enabled formation of thick photoresist layers with minimal distortion. Photoresist molds were then employed for replica molding of LOC devices with poly(dimethylsiloxane) (PDMS) elastomer. The complete bioanalytical system consisted of: (i) microfluidic PDMS chip-based device; (ii) peristaltic microperfusion pumping manifold; (iii) miniaturized CMOS camera for video data acquisition; and (iv) video analysis software algorithms for quantification of changes in swimming behaviour of B. calyciflorus in response to reference toxicants.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124361031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Quantitative optical imaging of paracetamol-induced metabolism changes in the liver 对乙酰氨基酚诱导的肝脏代谢变化的定量光学成像
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242962
Xiaowen Liang, Haolu Wang, Xin Liu, M. Roberts
{"title":"Quantitative optical imaging of paracetamol-induced metabolism changes in the liver","authors":"Xiaowen Liang, Haolu Wang, Xin Liu, M. Roberts","doi":"10.1117/12.2242962","DOIUrl":"https://doi.org/10.1117/12.2242962","url":null,"abstract":"Paracetamol is the most readily available and widely used painkiller. However, its toxicity remains the most common cause of liver injury. The toxicity of paracetamol has been attributing to its toxic metabolite, which depletes cellular glutathione (GSH) stores and reacts within cells to increase oxidative stress, leading to mitochondrial dysfunction and cell necrosis. Multiphoton microscopy (MPM) and fluorescence lifetime imaging (FLIM) can provide quantitative imaging of biological tissues and organs in vivo and allow direct visualization of cellular events, which were used to monitor cellular metabolism in paracetamol-induced toxicity in this study. To better understand mechanisms of paracetamol induced liver injury, the redox ratio of NADH/FAD in liver cells were detected and quantified by MPM imaging to represent the relative rates of glycolysis and oxidative phosphorylation within cells. Compared to normal liver, average fluorescence lifetime of NADH and redox ratio of NADH/FAD in hepatocytes was significantly decreased after paracetamol overdose for 12 and 24 hrs, reflecting impaired metabolic activity. GSH levels of treatment groups were significantly lower than those of normal livers, with gradually decreasing from periportal to centrilobular zonation. This imaging technique has significant implications for investigating metabolic mechanisms of paracetamol toxicity.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117185046","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Brain tumor classification of microscopy images using deep residual learning 基于深度残差学习的脑肿瘤显微图像分类
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242711
Yota Ishikawa, K. Washiya, Kota Aoki, H. Nagahashi
{"title":"Brain tumor classification of microscopy images using deep residual learning","authors":"Yota Ishikawa, K. Washiya, Kota Aoki, H. Nagahashi","doi":"10.1117/12.2242711","DOIUrl":"https://doi.org/10.1117/12.2242711","url":null,"abstract":"The crisis rate of brain tumor is about one point four in ten thousands. In general, cytotechnologists take charge of cytologic diagnosis. However, the number of cytotechnologists who can diagnose brain tumors is not sufficient, because of the necessity of highly specialized skill. Computer-Aided Diagnosis by computational image analysis may dissolve the shortage of experts and support objective pathological examinations. Our purpose is to support a diagnosis from a microscopy image of brain cortex and to identify brain tumor by medical image processing. In this study, we analyze Astrocytes that is a type of glia cell of central nerve system. It is not easy for an expert to discriminate brain tumor correctly since the difference between astrocytes and low grade astrocytoma (tumors formed from Astrocyte) is very slight. In this study, we present a novel method to segment cell regions robustly using BING objectness estimation and to classify brain tumors using deep convolutional neural networks (CNNs) constructed by deep residual learning. BING is a fast object detection method and we use pretrained BING model to detect brain cells. After that, we apply a sequence of post-processing like Voronoi diagram, binarization, watershed transform to obtain fine segmentation. For classification using CNNs, a usual way of data argumentation is applied to brain cells database. Experimental results showed 98.5% accuracy of classification and 98.2% accuracy of segmentation.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129748805","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Optical tracking of embryonic vertebrates behavioural responses using automated time-resolved video-microscopy system 使用自动时间分辨视频显微系统的胚胎脊椎动物行为反应光学跟踪
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242828
M. Walpitagama, J. Kaslin, D. Nugegoda, D. Wlodkowic
{"title":"Optical tracking of embryonic vertebrates behavioural responses using automated time-resolved video-microscopy system","authors":"M. Walpitagama, J. Kaslin, D. Nugegoda, D. Wlodkowic","doi":"10.1117/12.2242828","DOIUrl":"https://doi.org/10.1117/12.2242828","url":null,"abstract":"The fish embryo toxicity (FET) biotest performed on embryos of zebrafish (Danio rerio) has gained significant popularity as a rapid and inexpensive alternative approach in chemical hazard and risk assessment. The FET was designed to evaluate acute toxicity on embryonic stages of fish exposed to the test chemical. The current standard, similar to most traditional methods for evaluating aquatic toxicity provides, however, little understanding of effects of environmentally relevant concentrations of chemical stressors. We postulate that significant environmental effects such as altered motor functions, physiological alterations reflected in heart rate, effects on development and reproduction can occur at sub-lethal concentrations well below than LC10. Behavioral studies can, therefore, provide a valuable integrative link between physiological and ecological effects. Despite the advantages of behavioral analysis development of behavioral toxicity, biotests is greatly hampered by the lack of dedicated laboratory automation, in particular, user-friendly and automated video microscopy systems. In this work we present a proof-of-concept development of an optical system capable of tracking embryonic vertebrates behavioral responses using automated and vastly miniaturized time-resolved video-microscopy. We have employed miniaturized CMOS cameras to perform high definition video recording and analysis of earliest vertebrate behavioral responses. The main objective was to develop a biocompatible embryo positioning structures that were suitable for high-throughput imaging as well as video capture and video analysis algorithms. This system should support the development of sub-lethal and behavioral markers for accelerated environmental monitoring.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129115349","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Using DNA nanostructures to harvest light and create energy transfer and harvesting systems 利用DNA纳米结构来收集光线,创造能量转移和收集系统
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242727
S. A. Díaz, Susan Buckhout‐White, Carl W. Brown, Anirban Samanta, W. P. Klein, M. Ancona, C. Dwyer, E. Goldman, J. Melinger, P. Cunningham, C. Spillmann, Igor L. Medintz
{"title":"Using DNA nanostructures to harvest light and create energy transfer and harvesting systems","authors":"S. A. Díaz, Susan Buckhout‐White, Carl W. Brown, Anirban Samanta, W. P. Klein, M. Ancona, C. Dwyer, E. Goldman, J. Melinger, P. Cunningham, C. Spillmann, Igor L. Medintz","doi":"10.1117/12.2242727","DOIUrl":"https://doi.org/10.1117/12.2242727","url":null,"abstract":"DNA is a biocompatible scaffold that allows for the design of a variety of nanostructures, from straightforward double stranded DNA to more complex DNA origami and 3-D structures. By modifying the structures, with dyes, nanoparticles, or enzymes, they can be used to create light harvesting and energy transfer systems. We have focused on using Förster resonance energy transfer (FRET) between organic fluorophores separated with nanometer precision based on the DNAs defined positioning. Using FRET theory we can control the direction of the energy flow and optimize the design parameters to increase the systems efficiency. The design parameters include fluorophore selection, separation, number, and orientation among others. Additionally the use of bioluminescence resonance energy transfer (BRET) allowed the use of chemical energy, as opposed to photonic, to activate the systems. Here we discuss a variety of systems, such as the longest reported DNA-based molecular photonic wires (> 30 nm), dendrimeric light harvesting systems, and semiconductor nanocrystals integrated systems where they act as both scaffold and antennae for the original excitation. Using a variety of techniques, a comparison of different types of structures as well as heterogeneous vs. homogenous FRET was realized.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126404079","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Miniaturized video-microscopy system for near real-time water quality biomonitoring using microfluidic chip-based devices 基于微流控芯片设备的近实时水质生物监测的微型视频显微镜系统
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242826
Yushi Huang, Abhimanyu Nigam, O. Campana, D. Nugegoda, D. Wlodkowic
{"title":"Miniaturized video-microscopy system for near real-time water quality biomonitoring using microfluidic chip-based devices","authors":"Yushi Huang, Abhimanyu Nigam, O. Campana, D. Nugegoda, D. Wlodkowic","doi":"10.1117/12.2242826","DOIUrl":"https://doi.org/10.1117/12.2242826","url":null,"abstract":"Biomonitoring studies apply biological responses of sensitive biomonitor organisms to rapidly detect adverse environmental changes such as presence of physic-chemical stressors and toxins. Behavioral responses such as changes in swimming patterns of small aquatic invertebrates are emerging as sensitive endpoints to monitor aquatic pollution. Although behavioral responses do not deliver information on an exact type or the intensity of toxicants present in water samples, they could provide orders of magnitude higher sensitivity than lethal endpoints such as mortality. Despite the advantages of behavioral biotests performed on sentinel organisms, their wider application in real-time and near realtime biomonitoring of water quality is limited by the lack of dedicated and automated video-microscopy systems. Current behavioral analysis systems rely mostly on static test conditions and manual procedures that are time-consuming and labor intensive. Tracking and precise quantification of locomotory activities of multiple small aquatic organisms requires high-resolution optical data recording. This is often problematic due to small size of fast moving animals and limitations of culture vessels that are not specially designed for video data recording. In this work, we capitalized on recent advances in miniaturized CMOS cameras, high resolution optics and biomicrofluidic technologies to develop near real-time water quality sensing using locomotory activities of small marine invertebrates. We present proof-of-concept integration of high-resolution time-resolved video recording system and high-throughput miniaturized perfusion biomicrofluidic platform for optical tracking of nauplii of marine crustacean Artemia franciscana. Preliminary data demonstrate that Artemia sp. exhibits rapid alterations of swimming patterns in response to toxicant exposure. The combination of video-microscopy and biomicrofluidic platform facilitated straightforward recording of fast moving objects. We envisage that prospectively such system can be scaled up to perform high-throughput water quality sensing in a robotic biomonitoring facility.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"106 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121505771","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Modulating molecular transport across peptide-modified nanoporous alumina membranes with light 光调节多肽修饰纳米多孔氧化铝膜上的分子运输
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2241495
T. Kumeria, Jingxian Yu, M. Alsawat, Mahaveer D. Kurkuri, Abel Santos, Andrew D. Abell, D. Losic
{"title":"Modulating molecular transport across peptide-modified nanoporous alumina membranes with light","authors":"T. Kumeria, Jingxian Yu, M. Alsawat, Mahaveer D. Kurkuri, Abel Santos, Andrew D. Abell, D. Losic","doi":"10.1117/12.2241495","DOIUrl":"https://doi.org/10.1117/12.2241495","url":null,"abstract":"We designed and fabricated a smart and stimuli responsive membrane to cater on demand molecular transporting applications. A novel photoswitchable peptide (PSP) was synthesized and attached inside nanoporous anodic alumina membranes (NAAMs) pores. The PSP specifically switched between its cis and trans photostationary states on exposure to 364 nm and 440 nm wavelength lights respectively, which not only provided the ability to control its pore diameter but also the surface chemistry. The switchable molecular transport properties of the PSP-NAAMs have been shown as a function of the light exposure. Most importantly, the molecular transport across PSP-NAAMs could be repeatedly switched between on and off state, which is highly significant for on-demand triggered drug release systems.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125221437","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Optofluidic whispering gallery mode microcapillary lasers for refractive index sensing 用于折射率传感的光流体窃窃廊模式微毛细管激光器
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2242705
A. François, N. Riesen, K. Gardner, T. Monro, A. Meldrum
{"title":"Optofluidic whispering gallery mode microcapillary lasers for refractive index sensing","authors":"A. François, N. Riesen, K. Gardner, T. Monro, A. Meldrum","doi":"10.1117/12.2242705","DOIUrl":"https://doi.org/10.1117/12.2242705","url":null,"abstract":"Whispering gallery modes (WGMs) allow for remarkable refractive index sensing performance with extremely low detection limits, and thus have found use in various emerging label free biosensing applications. Among the different types of resonators which have been studied, microcapillaries have the unique property of having the evanescent fields extend into and sample the medium inside the resonator, which is particularly interesting because the resonator itself serves as a microfluidic channel. Here, lasing of the WGMs in fluorescent microcapillaries is demonstrated for the first time, and their application to refractive index sensing is investigated. The laser gain medium used here is embedded inside a high refractive index polymer coating deposited onto the inner surface of the capillary. Lasing can only be realized for thick polymer coatings (in this case ≥ 800 nm), with higher Q factor but also stronger confinement of the propagating wave, which lowers the refractive index sensitivity compared to non-lasing capillaries which can have thinner polymer coatings. We however find that the large improvement in signal-to-noise ratio and Q factor realized upon lasing more than compensates for the reduced sensitivity, resulting in an order-of-magnitude improvement in the detection limit for refractive index sensing.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125352044","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Onion-like surface design of upconverting nanophosphors modified with polyethylenimine: shielding toxicity versus keeping brightness? 聚乙烯亚胺修饰的上转换纳米荧光粉的洋葱状表面设计:屏蔽毒性还是保持亮度?
Biophotonics Australasia Pub Date : 2016-12-09 DOI: 10.1117/12.2244636
Anna E Guller, A. Nadort, A. Generalova, I. Kornienko, Elena Petersen, Yi Qian, A. Shekhter, E. Goldys, A. Zvyagin
{"title":"Onion-like surface design of upconverting nanophosphors modified with polyethylenimine: shielding toxicity versus keeping brightness?","authors":"Anna E Guller, A. Nadort, A. Generalova, I. Kornienko, Elena Petersen, Yi Qian, A. Shekhter, E. Goldys, A. Zvyagin","doi":"10.1117/12.2244636","DOIUrl":"https://doi.org/10.1117/12.2244636","url":null,"abstract":"Background: Upconverting nanoparticles (UCNPs) represent a unique class of nanomaterials, able to convert infrared excitation light into long lifetime visible and infrared photoluminescence, within the “optical transparency window” of biological tissues. This makes UCNPs an attractive contrast agent for background-free bioimaging. However, assynthesized UCNPs are hydrophobic and need additional surface coating for stability in water-based solutions and further functionalization. Polyethylenimine (PEI), a polycationic amphiphilic polymer, is a well-known transfection agent for gene delivery and a popular material for UCNPs surface hydrophilization. Combining the functional properties of UCNPs and PEI is extremely useful for precise visualization of genetic manipulations and intracellular drug delivery. At the same time, PEI is toxic to cells, while the photoluminescent properties of UCNPs are very sensitive to surface chemistry and environment. Then, creation of hydrophilic, biocompatible and simultaneously bright UCNPs, modified by PEI (UCNP-PEI), is a challenging task. Objectives: To analyze the effects of multilayer shielding coatings on cytotoxicity, cellular uptake and photoluminescent properties of UCNP-PEI. Methods and results: UCNP-PEI were modified with additional two or three layers of various polymers and characterized by size, surface charge and photophysical properties. HaCaT keratinocytes were exposed to the particles for 24 or 120 h to study the cytotoxicity and cellular uptake. The results show that onion-like coatings of UCNP-PEI simultaneously decrease cytotoxicity and relative luminescence of the particles, depending on structure and method of formation of multilayer coating. Conclusions: Rational design of UCNP-PEI using extra coatings layers can help to keep acceptable levels of biocompatibility and photoluminescence intensity.","PeriodicalId":220656,"journal":{"name":"Biophotonics Australasia","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132850457","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书