{"title":"PERANCANGAN SISTEM CHARGING CONTROL PHOTOVOLTAIC DENGAN SISTEM MPPT MENGGUNAKAN METODE INCREMENTAL CONDUCTANCE","authors":"Hardiansyah Randa, Selamat Meliala","doi":"10.29103/jee.v11i1.7724","DOIUrl":"https://doi.org/10.29103/jee.v11i1.7724","url":null,"abstract":"ini akan mengontrol buck-boost converter hasil penelitian ini charging control","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130056609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. T. Pangestu, M. Jannah, R. Rosdiana, Badriana Badriana
{"title":"Analisis Setting Over Current Relay Pada Penyulang Sungai Iyu Gardu Induk Tualang Cut","authors":"M. T. Pangestu, M. Jannah, R. Rosdiana, Badriana Badriana","doi":"10.29103/jee.v11i1.6709","DOIUrl":"https://doi.org/10.29103/jee.v11i1.6709","url":null,"abstract":"Abstrak — Dalam sistem penyaluran listrik, banyak kendala atau gangguan yang terjadi. Faktor yang menyebabkan terjadinya gangguan sistem tenaga listrik antara lain disebabkan oleh keadaan alam, kelebihan beban, kawat penghantar putus serta gangguan hubung singkat. Untuk mengatasi gangguan tersebut dan melindungi peralatan listrik maka dipasang relay pengaman. Salah satu relai pengaman pada penyulang yaitu over current relay (OCR) , Relai ini berfungsi untuk mengamankan peralatan listrik dari kerusakan yang diakibatkan arus berlebih. Pada penelitian ini membahas setting OCR yang ada pada penyulang sungai iyu di gardu induk tualang cut. Dari hasil perhitungan didapat arus gangguan hubung singkat terbesar terjadi pada gangguan 3 fasa di titik 0% yaitu 12907.44 A, arus gangguan terkecil terjadi pada gangguan 2 fasa di titik 100% yaitu 1889.73 A. Nilai setting OCR sisi penyulang adalah Iprimer = 300.3 A, Isekunder = 5.005 A , Tms = 0.17 s, nilai setting OCR sisi incoming adalah Iprimer = 1905.2 A, Isekunder = 4.763 A, Tms = 0.2 s. Berdasarkan hasil perhitungan setting OCR penyulang sungai","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128563188","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Muhammad Muhammad, Selamat Meliala, Damayanti Damayanti
{"title":"MENGATASI BEBAN LEBIH TRANSFORMATOR GARDU DISTRIBUSI DENGAN MENGGUNAKAN TRAFO SISIP DI PT PLN (Persero) ULP LANGSA KOTA","authors":"Muhammad Muhammad, Selamat Meliala, Damayanti Damayanti","doi":"10.29103/jee.v11i1.7735","DOIUrl":"https://doi.org/10.29103/jee.v11i1.7735","url":null,"abstract":"Abstrak— Transformator distribusi merupakan salah satu komponen yang sangat penting dalam penyaluran tenaga listrik dari gardu distribusi ke pelanggan. Pelayanan terhadap pelanggan akan terganggu sehingga apabila terjadi pemutusan aliran listrik atau pemadaman yang diakibatkan dari kerusakan pada Transformator Distribusi. Transformator distribusi yang mengalami beban yang melabihi 80% dari kapasitas transformator tersebut maka akan berefek pada umur/life time transformator distribusi dan juga dapat mempengaruhi tingkat dan mutu pelayanan pada konsumen serta berpotensi besar terjadi gangguan. Maka dari itu perlu dilakukan suatu tindakan agar persentase pembebanan transformator distribusi tidak melebihi kapasitas trnasformator dengan metode pemasangan Trafo Sisip. Motode penelitian dalam skripsi ini menggunakan metode kuantitatif dan juga menggunakan simulasi software ETAP 12.6.0. Di PT.PLN (Persero) ULP LANGSA KOTA terdapat transformator yang mengalami pembebanan berlebih (overload) yang terjadi pada Gardu Distribusi TC-7 sebesar 84,85% dan dilakukan pemasangan Trafo Sisip, pembebanan pada gardu TC-7 menjadi 49,65%. Dengan ini dapat dibuktikan bahwa pemasangan Trafo Sisip merupakan metode yang cukup baik untuk mengatasi gangguan pembebanan berlebih (Overload) pada Gardu TC-7, sehingga dapat memperpanjang umur trafo / life time transformator, menngkatkan kualitas pelayanan pada pelanggan dan mengurangi potensi terjadinya gangguan karena transformator pembebanan dibawah 80% dapat bekerja secara baik.","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131543121","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"ANALISA PENGARUH PERUBAHAN SUHU TERHADAP TEGANGAN PANEL SURYA JENIS MONO CHRYSTALLINE KAPASITAS DAYA 50 Wp","authors":"Ezwar Syah, Asri Asri, Andik Bintoro","doi":"10.29103/jee.v11i1.8260","DOIUrl":"https://doi.org/10.29103/jee.v11i1.8260","url":null,"abstract":"Secara geografis Indonesia berada pada daerah beriklim tropis yang mempunyai sinar matahari yang berlebih. Pemanfaatan sinar matahari tersebut untuk membangkitkan energi listrik yaitu menggunakan Panel Surya. Panel Surya merupakan elemen semikonduktor yang dapat mengkonversi sinar matahari yang berupa energi surya menjadi energi listrik dengan prinsip fotovoltaik. Intensitas radiasi cahaya matahari dan suhu udara lingkungan mempengaruhi tegangan dan arus yang dibangkitkan panel surya. Jika semakin rendah intensitas radiasi cahaya matahari maka akan rendah pula arus dan tegangan listrik yang dihasilkan panel. Tinggi rendahnya suhu lingkungan disekitar panel surya juga memiliki kontribusi dalam perubahan temperatur pada sel-sel surya. Dari hasil uji di Lhokseumawe menggunakan panel surya jenis Mono chrystalline silicon didapat jika kenaikan temperatur maka tegangan listrik yang dihasilkan oleh panel surya menjadi berkurang. Pengukuran tahap I pada temperatur tertinggi Celsius daya output adalah 31,9 Watt, hasil pengukuran tahap II pada temperatur tertinggi Celsius daya output adalah 32,2 Watt dan hasil pengukuran tahap III pada temperatur tertinggiCelsius daya output adalah 32,1 Watt","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122373402","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"SISTEM PENGAMAN PINTU OTOMATIS MENGGUNAKAN SENSOR RADIO FREQUENCY IDENTIFICATION (RFID) BERBASIS ARDUINO UNO","authors":"Muchtar Fauza, Muchlis Abdul Muthalib","doi":"10.29103/jee.v11i1.8185","DOIUrl":"https://doi.org/10.29103/jee.v11i1.8185","url":null,"abstract":"Abstrak Sistem keamanan yang dimiliki rumah khususnya masih banyak menggunakan penguncian manual yaitu menggunakan kunci biasa seperti kebanyakan orang, seiring dengan berkembangnya teknologi maka pengaplikasian mikrokontroler pada sistem keamananpun dapat diwujudkan dengan menggunakan perangkat elektronik sebagai alternatif pengganti sistem keamanan kunci konvensional. Perancangan sistem pengaman pintu otomatis ini dibuat karena kurang efisiennya pengaman pintu konfensional, masih menggunakan kunci fisik yang dimensinya masih tergolong besar dan juga membutuhkan waktu lebih lama untuk membuka pintu. Dengan adanya pengaman pintu otomatis ini kita dapat mempermudah membuka pintu hanya dengan menempelkan Id Card ke RFID reader. Alat pengaman pintu otomatis menggunakan Id Card sebagai tag dan RFRC522 sebagai reader dengan penerapan arduino uno sebagai kontrol pusat kendali rangkaian. Sensor RFID reader RFRC522 ini memiliki frekuensi 13.56Mhz.","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"78 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114872043","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Reza Fahlevi Nasrah, Muhammad Muhammad, Ezwarsyah Ezwarsyah
{"title":"Analisisa hubung singkat satu FASA ke tanah pada jaringan distribusi 20 kv PT.pln (Persero) Takengon menggunakan software etap 12.6.0","authors":"Reza Fahlevi Nasrah, Muhammad Muhammad, Ezwarsyah Ezwarsyah","doi":"10.29103/jee.v10i2.4930","DOIUrl":"https://doi.org/10.29103/jee.v10i2.4930","url":null,"abstract":"","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133391618","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"RANCANG BANGUN SISTEM PENYIRAMAN KLOSET MASJID OTOMATIS BERBASIS MIKROKONTROLER","authors":"Wanda Syahayu, M. A. Muthalib, K. Kartika","doi":"10.29103/jee.v10i2.6622","DOIUrl":"https://doi.org/10.29103/jee.v10i2.6622","url":null,"abstract":"","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124880224","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"STUDI KAPASITAS BATERAI 110 VOLT DC UNIT I PADA GARDU INDUK 150 KV BIREUEN","authors":"Selamat Meliala, M. Rijal, Taufiq Taufiq","doi":"10.29103/jee.v10i2.6202","DOIUrl":"https://doi.org/10.29103/jee.v10i2.6202","url":null,"abstract":"","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125583085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"SISTEM ANTISIPASI AIR PASANG DAN AIR SURUT PADA KOLAM IKAN MENGGUNAKAN SENSOR ULTRASONIC BERBASIS ARDUINO UNO","authors":"Hari Pratama Barus, Asran Asran, Andik Bintoro","doi":"10.29103/jee.v10i2.1908","DOIUrl":"https://doi.org/10.29103/jee.v10i2.1908","url":null,"abstract":"","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"35 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123356250","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
muhammad ilham manishe, Arnawan Hasibuan, Raihan Putri
{"title":"PERANCANGAN RADIAL FLUX PERMANENT MAGNET SYNCHRONOUS GENERATOR SEBAGAI PEMBANGKIT LISTRIK TENAGA ANGIN MENGGUNAKAN FINITE ELEMENT METHOD (FEM)","authors":"muhammad ilham manishe, Arnawan Hasibuan, Raihan Putri","doi":"10.29103/JEE.V10I1.4895","DOIUrl":"https://doi.org/10.29103/JEE.V10I1.4895","url":null,"abstract":"Penelitian ini tentang perancangan desain dan simulasi Permanent Magnet Synchronous Generator (PMSG) yang memiliki prospek cerah dalam aplikasi turbin angin skala kecil. Turbin angin sebagai pembangkit listrik yang menjadi kebutuhan yang sangat penting dalam kehidupan manusia. Pembangkit listrik yang murah dan mudah dengan tingkat efesiensi yang tinggi adalah salah satu jawaban atas permasalahan akan kebutuhan listrik. Metode Fenite Element Method (FEM) adalah alat untuk mempelajari dan merancang Permanent Magnet Synchronous Generator (PMSG). Penelitian ini bertujuan untuk merancang model Permanent Magnet Synchronous Generator (PMSG), Generator yang diracang memiliki jumlah 18 slot ,16 pole dan 3 fasa dengan menggunakan radial flux . Hasil dari pemodelan dan simulasi PMSG ini dapat membangkitkan daya sebesar 661,234 Watt pada kecepatan 1000 RPM dengan efisiensi mencapai 81 %.","PeriodicalId":220025,"journal":{"name":"Jurnal Energi Elektrik","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115609606","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}