Pooneh Roshanitabrizi, Kelsey Brown, A. Tompsett, A. Paulli, J. Rwebembera, E. Okello, L. Zühlke, M. Mirabel, M. C. Nunes, A. Beaton, C. Sable, M. Linguraru
{"title":"Analysis of Mitral Regurgitation Jet for Rheumatic Heart Disease Detection in Doppler Echocardiography","authors":"Pooneh Roshanitabrizi, Kelsey Brown, A. Tompsett, A. Paulli, J. Rwebembera, E. Okello, L. Zühlke, M. Mirabel, M. C. Nunes, A. Beaton, C. Sable, M. Linguraru","doi":"10.1109/ISBI53787.2023.10230680","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230680","url":null,"abstract":"Rheumatic heart disease (RHD) is a common condition in young children living in low- and middle-income countries where cardiology expertise is insufficiently available. Mitral regurgitation (MR) is an important imaging feature used to diagnose RHD. We present a new, automatic framework to detect and characterize the MR jet on color Doppler echocardiograms, followed by RHD detection. Our method includes (1) echocardiogram harmonization, (2) localization and characterization of the maximum MR jet, and (3) RHD detection. We evaluated the performance using 1,807 color Doppler echocardiograms from 511 children with MR on two acquisition views (parasternal and apical). We localized the maximum MR jet and measured the length with an accuracy similar to that of expert manual measurements (p-value = 0.83), resulting in an average accuracy of 0.86, sensitivity of 0.92, and specificity of 0.79 for RHD detection. Our automatic approach has the potential to detect RHD as reliably as expert clinicians.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115005150","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Classifying Patients with pFC Lesions from Healthy Controls Using Directed Information Based Effective Brain Connectivity Measured from the Encoding Phase of Working Memory Task","authors":"Sai Sanjay Balaji, K. Parhi","doi":"10.1109/ISBI53787.2023.10230817","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230817","url":null,"abstract":"This paper describes a group-level analysis of 14 subjects with prefrontal cortex (pFC) lesions and 20 healthy controls performing multiple lateralized visuospatial working memory (WM) trials. Using effective brain connectivity measures inferred from directed information (DI) during memory encoding, we first show that DI features can correctly classify 18 control subjects and 11 subjects with pFC lesions, providing an overall accuracy of 85.3%. Second, we show that differential DI, the change in DI during the encoding phase from pretrial, can successfully overcome inter-subject variability and correctly identify the class of all 34 subjects (100% accuracy). These accuracy results are based on two-thirds majority thresholding among all trials. Finally, we use Welch’s t-test to identify the crucial differences in the two classes’ sub-networks responsible for memory encoding. While the inflow of information to the prefrontal region is significant among subjects with pFC lesions, the outflow from the prefrontal to the frontal and central regions is diminished compared to the control subjects. We further identify specific neural pathways that are exclusively activated for each group during the encoding phase.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117229912","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Lesion Size Assessment on Multi-Frequency Single Transducer-Harmonic Motion Imaging Using Convolutional Neural Network","authors":"Shiqi Hu, M. Hossain, X. Li, E. Konofagou","doi":"10.1109/ISBI53787.2023.10230588","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230588","url":null,"abstract":"Medical imaging-derived tumor or lesion size quantification provides clinically relevant information for diagnosis and treatment monitoring. Multi-frequency single transducer harmonic motion imaging (ST-HMI) is an acoustic radiation force (ARF) based ultrasound elastography method that interrogates tissue mechanical properties by transmitting a multi-frequency ARF excitation pulse and estimating the induced oscillatory displacements at 100-1000 Hz frequency simultaneously. In this study, an automated lesion size assessment method is presented using the U2Net-based convolutional neural network (CNN) model. The training-validation set contains 1094 multi-frequency ST-HMI images of heterogeneous phantoms with the inclusion’s Young’s moduli ranging from 6-70 kPa and diameters ranging from 1.7-10.5 mm. For each of the 1094 images, ST-HMI-derived normalized peak-to-peak displacement (P2PD) images at 100-1000 Hz in the step of 100 Hz were used as the input to the U2Net. Dice score, sensitivity, specificity, and area estimation error were used to evaluate the performance of the model in the test phantom data set, in vivo 4T1 breast cancer mouse tumors, and ex vivo focused ultrasound (FUS)-induced thermal lesions. The average ± standard deviation of (Dice score, sensitivity, and specificity) was (0.92±0.04, 0.92±0.05, 0.99±0.01), and (0.87±0.07, 0.96±0.04, 0.95±0.04) in the phantoms and mouse tumors, respectively. The average absolute error in the model-predicted area of FUS-induced lesion was 9.45±0.77%. These results demonstrated the potential of multi-frequency ST-HMI to determine tumor size change in chemotherapy treatment monitoring and lesion size in ablation therapy guidance using CNN.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121028673","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Structure Constrained Diffusion Models for Pterygium Segmentation","authors":"Xinyu Guo, Zhouqian Wang, Huaying Hao, Qinxiang Zheng, Jiong Zhang, Wei Chen, Yitian Zhao","doi":"10.1109/ISBI53787.2023.10230558","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230558","url":null,"abstract":"Pterygium is a progressive blinding disease, mostly encroaching on the cornea from the nasal bulbar conjunctiva. In clinical practice, pterygium is generally classified according to the degree of invasion into the cornea and pupil. Consequently, the detection and quantification of different ocular surface structure, i.e., pterygium, cornea, and pupil is of great importance for the accurate diagnosis and prediction of the disease progression. In this paper, we propose a Structure Constrained Diffusion Models (SCDM) for pterygium, cornea, and pupil segmentation in ocular surface images. The proposed method transforms pixel-level segmentation into a conditional generation task, which takes the ocular surface image as a condition to guide the diffusion models for generating the mask from Gaussian noise. To be more specific, we improve the model by using a multi-layer conditional guidance to reduce the randomness of diffusion models. We then develop a mixed loss function to increase the structure constraints of estimated mask in the reverse process. Finally, a novel deterministic sampling strategy is introduced to effectively accelerate the sampling process and provide the deterministic sampling space. Experimental results show that the proposed method outperforms other state-of-the-art methods by providing more accurate segmentation performances.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127377385","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Full Wave Inversion For Ultrasound Tomography Using Physics Based Deep Neural Network","authors":"Xilun Liu, M. Almekkawy","doi":"10.1109/ISBI53787.2023.10230537","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230537","url":null,"abstract":"Ultrasound Computed Tomography (USCT) is a promising imaging modality for reconstructing tissue properties. Full-wave inversion (FWI) provides an enhanced contrast image. In this paper, we introduce an optimized Physics-Informed Neural Network (PINN) architecture to solve the inverse problems of FWI. PINNs are neural networks that can approximate universal functions using partial differential equations that govern the physics of the system. When training the network, the deep neural network can converge to learn the solutions of the wave equation by minimizing the loss function. The results showed that our proposed networks can retrieve the Speed of Sound (SoS) information and significantly decrease the computational cost via the transfer learning technique.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127520443","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transformer-Based Multimodal Fusion for Survival Prediction by Integrating Whole Slide Images, Clinical, and Genomic Data","authors":"Yihang Chen, Wei Zhao, Lequan Yu","doi":"10.1109/ISBI53787.2023.10230804","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230804","url":null,"abstract":"Survival prediction using whole slide images (WSIs) is a complex and difficult task, as handling gigapixel WSI directly is computationally impossible. In the past few years, people have worked out multiple instance learning (MIL) strategies to deal with WSIs, i.e., splitting WSI into many patches (instances) and aggregating features across patches. Moreover, to better predict the survival outcome of patients, different modalities have been explored, among which gene features are used the most frequently. In this paper, we explore a graph-based strategy to handle WSIs and investigate a transformer-based strategy to combine different modalities for survival prediction. Moreover, clinical data was also adopted and different encoding manners of clinical information were explored. Experiments on two public datasets from The Cancer Genome Atlas (TCGA) demonstrate the effectiveness of the proposed graph-transformer framework for survival prediction.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127540152","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"SynthMix: Mixing Up Aligned Synthesis for Medical Cross-Modality Domain Adaptation","authors":"Xinwen Zhang, Chaoyi Zhang, Dongnan Liu, Qianbi Yu, Weidong (Tom) Cai","doi":"10.1109/ISBI53787.2023.10230360","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230360","url":null,"abstract":"The adversarial methods showed advanced performance by producing synthetic images to mitigate the domain shift, a common problem due to the hardship of acquiring labelled data in medical field. Most existing studies focus on modifying the network architecture, but little has worked on the GAN training strategy. In this work, we propose SynthMix, an addon module with a natural yet effective training policy that can promote synthetic quality without altering the network architecture. Following the adversarial philosophy of GAN, we designed a mix-up synthesis scheme termed SynthMix. It coherently mixed up aligned images of real and synthetic samples to stimulate the generation of fine-grained features, examined by an associated Inspector for the domain-specific details. We evaluated our method on two segmentation benchmarks among three publicly available datasets, where our method showed a significant performance gain compared with existing state-of-the-art approaches. The code will be made publicly available.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124945894","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Kuruparan Shanmugalingam, D. Moses, A. Sowmya, E. Meijering
{"title":"Membranous Urethral Reconstruction and Segmentation in Multiplanar T2W MRI Images","authors":"Kuruparan Shanmugalingam, D. Moses, A. Sowmya, E. Meijering","doi":"10.1109/ISBI53787.2023.10230618","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230618","url":null,"abstract":"Multiplanar T2-weighted (T2W) magnetic resonance imaging (MRI) plays a key role in preoperative planning of surgical procedures for treating prostate cancer. It enables assessment of relevant anatomical structures such as the prostate gland, bladder and urethra before surgery, thereby preventing postoperative complications, such as urinary incontinence, which occurs when the membranous urethra (MU) is damaged. Manual measurement of MU properties such as length, volume and average radius is challenging and time consuming. To automate the task, we propose a novel semi-automated method that requires only very sparse expert manual annotations as input, and uses image preprocessing and fusion of active-contour-based segmentation techniques to produce the MU mask. We present preliminary quantitative and qualitative experimental results on clinical MRI data demonstrating the potential of our method and its capacity to produce MU measurements in agreement with clinicians.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125937696","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Q. Su, Na Wang, Jiawen Xie, Yinan Chen, Xiaofan Zhang
{"title":"Automatic Lobe Segmentation Using Attentive Cross Entropy and End-to-End Fissure Generation","authors":"Q. Su, Na Wang, Jiawen Xie, Yinan Chen, Xiaofan Zhang","doi":"10.1109/ISBI53787.2023.10230800","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230800","url":null,"abstract":"The automatic lung lobe segmentation algorithm is of great significance for the diagnosis and treatment of lung diseases, however, which has great challenges due to the incompleteness of pulmonary fissures in lung CT images and the large variability of pathological features. Therefore, we propose a new automatic lung lobe segmentation framework, in which we urge the model to pay attention to the area around the pulmonary fissure during the training process, which is realized by a task-specific loss function. In addition, we introduce an end-to-end pulmonary fissure generation method in the auxiliary pulmonary fissure segmentation task, without any additional network branch. Finally, we propose a registration-based loss function to alleviate the convergence difficulty of the Dice loss supervised pulmonary fissure segmentation task. We achieve 97.83% and 94.75% dice scores on our private dataset STLB and public LUNA16 dataset respectively.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116453871","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Qiang Liu, Jun Shi, Liang Qiao, Ziqi Zhu, Hong An, Minfan Zhao
{"title":"FRNET: An Effective Hybrid Structure for Automatic Segmentation of Head and Neck Primary Tumors from Multimodal Images","authors":"Qiang Liu, Jun Shi, Liang Qiao, Ziqi Zhu, Hong An, Minfan Zhao","doi":"10.1109/ISBI53787.2023.10230383","DOIUrl":"https://doi.org/10.1109/ISBI53787.2023.10230383","url":null,"abstract":"Accurate segmentation of primary tumors from Computed Tomography (CT) and Positron Emission Tomography (PET) images is essential for Head-and-Neck (H&N) cancer radiotherapy planning. However, manual delineation is time-consuming, and its accuracy heavily depends on the operator’s experience. Despite the great success of Convolutional Neural Networks (CNNs) in medical image segmentation, the inherent locality of convolutional layers limits the performance of most existing methods. Given the effectiveness of self-attention mechanisms in modeling long-range dependencies, Transformers have been introduced into CNNs as an alternative. However, pure Transformers require large amounts of data to learn inductive biases. This paper proposes a novel hybrid structure called FRNet, equipped with the learnable Feature Refinement Module (FRM), which combines transformer blocks and convolutional layers to enhance contextual information. Furthermore, we redesign the encoder block to improve the feature quality further. Experimental results on a large public dataset demonstrate that our method outperforms existing state-of-the-art methods.","PeriodicalId":211869,"journal":{"name":"2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114385247","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}