Restoration of Buildings and Monuments最新文献

筛选
英文 中文
Composition and Properties of SHCC; Part II: Influence of Elevated Temperatures and Freeze-thaw Cycles on Strain Hardening Cement-based Composites SHCC的组成及性能研究第二部分:高温和冻融循环对应变硬化水泥基复合材料的影响
Restoration of Buildings and Monuments Pub Date : 2014-04-01 DOI: 10.1515/rbm14.20.2-0011
R. Wu, P. Wang, F. Wittmann, T. Zhao
{"title":"Composition and Properties of SHCC; Part II: Influence of Elevated Temperatures and Freeze-thaw Cycles on Strain Hardening Cement-based Composites","authors":"R. Wu, P. Wang, F. Wittmann, T. Zhao","doi":"10.1515/rbm14.20.2-0011","DOIUrl":"https://doi.org/10.1515/rbm14.20.2-0011","url":null,"abstract":"","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"136 1","pages":"111 - 116"},"PeriodicalIF":0.0,"publicationDate":"2014-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73963515","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Time-dependent Moisture Distribution in Drying Cement Mortars – Results of Neutron Radiography and Inverse Analysis of Drying Tests 干燥水泥砂浆中随时间变化的水分分布。干燥试验的中子射线照相和反分析结果
Restoration of Buildings and Monuments Pub Date : 2014-02-01 DOI: 10.12900/rbm14.20.1-0004
B. Villmann, Volker Slowik, F. H. Wittmann, P. Vontobel, J. Hovind
{"title":"Time-dependent Moisture Distribution in Drying Cement Mortars – Results of Neutron Radiography and Inverse Analysis of Drying Tests","authors":"B. Villmann, Volker Slowik, F. H. Wittmann, P. Vontobel, J. Hovind","doi":"10.12900/rbm14.20.1-0004","DOIUrl":"https://doi.org/10.12900/rbm14.20.1-0004","url":null,"abstract":"The moisture transport properties of cementitious materials may be determined by inverse analysis of easy-to-perform drying experiments. A corresponding method is proposed. It requires the measurement of the time-dependent mass loss of drying samples, includes the numerical simulation of drying, and utilizes an evolutionary optimization algorithm for identifying the moisture transport parameters. By this method, inverse analyses of drying experiments with mortar samples have been carried out whereby different physical models for the moisture transport were applied. Neutron radiographic investigations served for validating the results. The radiographically measured moisture distributions in drying samples were compared to those obtained on the basis of inverse analyses of drying experiments. It was found that different transport models which consider both vapor and liquid water transport yield almost the same results. The latter were also in good agreement with the neutron radiographic observations.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"29 1","pages":"49 - 62"},"PeriodicalIF":0.0,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82284949","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Interdisciplinary Research about Bourbon's Architectural Heritage: the Case-study of the Immacolatella in Naples 波旁王朝建筑遗产的跨学科研究:那不勒斯Immacolatella的案例研究
Restoration of Buildings and Monuments Pub Date : 2014-02-01 DOI: 10.1515/rbm14.20.1-0003
V. Russo, P. Cappelletti, S. Pollone, C. D. Benedetto
{"title":"Interdisciplinary Research about Bourbon's Architectural Heritage: the Case-study of the Immacolatella in Naples","authors":"V. Russo, P. Cappelletti, S. Pollone, C. D. Benedetto","doi":"10.1515/rbm14.20.1-0003","DOIUrl":"https://doi.org/10.1515/rbm14.20.1-0003","url":null,"abstract":"","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"16 1","pages":"25 - 48"},"PeriodicalIF":0.0,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74919140","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Time-dependent Moisture Distribution in Drying Cement Mortars – Results of Neutron Radiography and Inverse Analysis of Drying Tests 干燥水泥砂浆中随时间变化的水分分布。干燥试验的中子射线照相和反分析结果
Restoration of Buildings and Monuments Pub Date : 2014-02-01 DOI: 10.1515/rbm14.20.1-0004
B. Villmann, V. Slowik, F. Wittmann, P. Vontobel, J. Hovind
{"title":"Time-dependent Moisture Distribution in Drying Cement Mortars – Results of Neutron Radiography and Inverse Analysis of Drying Tests","authors":"B. Villmann, V. Slowik, F. Wittmann, P. Vontobel, J. Hovind","doi":"10.1515/rbm14.20.1-0004","DOIUrl":"https://doi.org/10.1515/rbm14.20.1-0004","url":null,"abstract":"The moisture transport properties of cementitious materials may be determined by inverse analysis of easy-to-perform drying experiments. A corresponding method is proposed. It requires the measurement of the time-dependent mass loss of drying samples, includes the numerical simulation of drying, and utilizes an evolutionary optimization algorithm for identifying the moisture transport parameters. By this method, inverse analyses of drying experiments with mortar samples have been carried out whereby different physical models for the moisture transport were applied. Neutron radiographic investigations served for validating the results. The radiographically measured moisture distributions in drying samples were compared to those obtained on the basis of inverse analyses of drying experiments. It was found that different transport models which consider both vapor and liquid water transport yield almost the same results. The latter were also in good agreement with the neutron radiographic observations.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"8 1","pages":"49 - 62"},"PeriodicalIF":0.0,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86111091","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 22
Collapse and Reconstruction of the Tower of the St Willibrordus Church at Meldert Lummen (B) Meldert Lummen的St willibrorus教堂塔楼的倒塌和重建(B)
Restoration of Buildings and Monuments Pub Date : 2014-02-01 DOI: 10.12900/rbm14.20.1-0002
D. Gemert, P. Vos, S. Ignoul
{"title":"Collapse and Reconstruction of the Tower of the St Willibrordus Church at Meldert Lummen (B)","authors":"D. Gemert, P. Vos, S. Ignoul","doi":"10.12900/rbm14.20.1-0002","DOIUrl":"https://doi.org/10.12900/rbm14.20.1-0002","url":null,"abstract":"The collapse of the tower of the St Willibrordus church at Meldert/Lummen on July 7, 2006 was a traumatic experience for many members of the village community. This paper deals with the multi-disciplinary investigation of the causes of the tower collapse. The correct understanding of the damage phenomena as well as of the collapse mechanism enables to develop the appropriate concepts and technologies for the renovation of the tower and for the restoration of the damaged parts of the church nave. The important phases of the restoration project are described. The restoration was executed in the period 2011-2013.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"11 1","pages":"24 - 3"},"PeriodicalIF":0.0,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73024717","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Early Information on Corrosion Initiation in Reinforced Concrete Structures Exposed to Aggressive Environment 暴露于腐蚀性环境下钢筋混凝土结构腐蚀起始的早期信息
Restoration of Buildings and Monuments Pub Date : 2014-02-01 DOI: 10.1515/rbm14.20.1-0005
Z. Bi, P. Zhang, F. Wittmann, T. Zhao, P. Wang
{"title":"Early Information on Corrosion Initiation in Reinforced Concrete Structures Exposed to Aggressive Environment","authors":"Z. Bi, P. Zhang, F. Wittmann, T. Zhao, P. Wang","doi":"10.1515/rbm14.20.1-0005","DOIUrl":"https://doi.org/10.1515/rbm14.20.1-0005","url":null,"abstract":"","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"19 1","pages":"63 - 70"},"PeriodicalIF":0.0,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83805811","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Collapse and Reconstruction of the Tower of the St Willibrordus Church at Meldert Lummen (B) Meldert Lummen的St willibrorus教堂塔楼的倒塌和重建(B)
Restoration of Buildings and Monuments Pub Date : 2014-02-01 DOI: 10.1201/9781315616995-229
D. Gemert, P. Vos, S. Ignoul
{"title":"Collapse and Reconstruction of the Tower of the St Willibrordus Church at Meldert Lummen (B)","authors":"D. Gemert, P. Vos, S. Ignoul","doi":"10.1201/9781315616995-229","DOIUrl":"https://doi.org/10.1201/9781315616995-229","url":null,"abstract":"","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"30 1","pages":"3 - 24"},"PeriodicalIF":0.0,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83286025","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Interdisciplinary Research about Bourbon's Architectural Heritage: the Case-study of the Immacolatella in Naples 波旁王朝建筑遗产的跨学科研究:那不勒斯Immacolatella的案例研究
Restoration of Buildings and Monuments Pub Date : 2014-02-01 DOI: 10.12900/rbm14.20.1-0003
V. Russo, P. Cappelletti, S. Pollone, C. D. Benedetto
{"title":"Interdisciplinary Research about Bourbon's Architectural Heritage: the Case-study of the Immacolatella in Naples","authors":"V. Russo, P. Cappelletti, S. Pollone, C. D. Benedetto","doi":"10.12900/rbm14.20.1-0003","DOIUrl":"https://doi.org/10.12900/rbm14.20.1-0003","url":null,"abstract":"The Immacolatella building in the port of Naples is one of the last examples of the modern planning supported by Charles III in order to make Naples the new capital of the Spanish Reign of Bourbon in mid-18th century. It is a very important symbol in the Neapolitan memory of the emigration to the United States in early 1900s. Despite its historical value, the building is affected by severe decay due to both negligence and weathering, which are caused by its onshore location. This paper shows the results of interdisciplinary research undertaken in the University of Naples with the aim of giving a preliminary knowledge for its preservation. By means of historical sources and mensio-chronological analyses, the building development was retraced. Moreover, laboratory tests were carried out in order to collect information about geomaterials. The collected data show the high vulnerabilities of this Royal building and the need to create a multidisciplinary strategy for its preservation.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"9 1","pages":"25 - 48"},"PeriodicalIF":0.0,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89986583","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Historical Floors in Venice for Industrial and Commercial Use (seminato veneziano) 威尼斯工业和商业用途的历史地板(seminato veneziano)
Restoration of Buildings and Monuments Pub Date : 2014-01-01 DOI: 10.12900/rbm14.20.3-0018
C. Milan, S. Tattoni
{"title":"Historical Floors in Venice for Industrial and Commercial Use (seminato veneziano)","authors":"C. Milan, S. Tattoni","doi":"10.12900/rbm14.20.3-0018","DOIUrl":"https://doi.org/10.12900/rbm14.20.3-0018","url":null,"abstract":"Historical floors in Venice, which can cover large surfaces and have a significant aesthetic value, are made of a homogeneous mixture of lime and aggregate. This allows them to adapt to the movements of the structure to avoid the formation of cracks, and to support heavy loads associated with the commercial and industrial use of the building. From a static point of view, they can be considered as floors on an elastic structure. Load tests together with the related calculations will be analysed using a FEM software and some particularly significant examples of historic buildings will be exposed.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"115 1","pages":"171 - 182"},"PeriodicalIF":0.0,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79122298","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Penetration of Water and Chloride Dissolved in Water into Concrete under Hydraulic Pressure 水压作用下水和水中氯离子对混凝土的渗透
Restoration of Buildings and Monuments Pub Date : 2014-01-01 DOI: 10.12900/rbm14.20.2-0012
Y. Zhao, F. Wittmann, P. Zhang, P. Wang, T. Zhao
{"title":"Penetration of Water and Chloride Dissolved in Water into Concrete under Hydraulic Pressure","authors":"Y. Zhao, F. Wittmann, P. Zhang, P. Wang, T. Zhao","doi":"10.12900/rbm14.20.2-0012","DOIUrl":"https://doi.org/10.12900/rbm14.20.2-0012","url":null,"abstract":"Migration of dissolved ions into concrete by capillary absorption (convection) and by diffusion has been studied in great detail in recent years. These two processes are considered to be major mechanisms of chloride penetration into concrete in contact with seawater or with water containing deicing salt. In practice, however, there exist many reinforced concrete structures, such as harbor constructions, subsea tunnels or bridge pillars, which are in permanent or temporary contact with salt containing water under considerable hydrostatic pressure. Penetration of chloride into concrete under hydrostatic pressure has been investigated to the same extent so far. Chloride penetration into concrete under the influence of a hydrostatic pressure has been studied on five types of concrete. The influence of blended cements has been investigated in particular. The results indicate that a pressure less than 0.1 MPa has hardly any influence on chloride penetration. Once the water pressure overcomes 0.3 MPa, the water and chloride penetration depth as well as the chloride content at a given exposure time increase significantly. If fly ash and slag are added to Portland cement, the resistance with respect to water and chloride penetration increases. Longer moist curing reduces the rate of chloride penetration. If an aqueous salt solution penetrates into concrete under hydrostatic pressure, the dissolved chloride does not follow the penetrating water but it is accumulated in a surface near zone. The porous structure of concrete obviously acts like a molecular filter. The ratio between water and chloride penetration depths can expressed by means of an exponential function.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"78 1","pages":"117 - 126"},"PeriodicalIF":0.0,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87558888","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信