S. Ola, A. Saraswat, S. Goyal, S. Jhajharia, Om Prakash Mahela
{"title":"A Technique Using Stockwell Transform Based Median for Detection of Power System Faults","authors":"S. Ola, A. Saraswat, S. Goyal, S. Jhajharia, Om Prakash Mahela","doi":"10.1109/POWERI.2018.8704459","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704459","url":null,"abstract":"Occurrence of the faults on transmission lines affects the performance of power system. These faults may cause interruption in the flow of power. Fast and accurate detection as well as location of these faults help in restoration of power supply in minimum time. This will result in improved reliability of power supply. This paper details an approach which helps to detect faults on the transmission line. The proposed approach uses Stockwell Transform based median to provide protection to the transmission line against power system faults such as line to ground, double line, double line to ground and three phase fault involving. Recording of the current signals is carried out on test node of test system. These signals are decomposed using Stockwell transform to obtain the S-matrix. The fault index is calculated using the median of this matrix which is found to be effective in detection and classification of faults in the power system network. Proposed study is performed using IEEE-34 node test system in MATLAB/Simulink environment.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124280127","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"AFLL Based Control Technique for Grid Interfaced Three Phase PV System","authors":"Bhim Singh, Vandana Jain","doi":"10.1109/POWERI.2018.8704428","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704428","url":null,"abstract":"This work proposes an advanced frequency locked loop (AFLL) based control algorithm for a three phase double stage grid interfaced solar photovoltaic (PV) system. The proposed AFLL based algorithm extracts the fundamental component of the load current (FCI) and improves the system performance during dynamics. The VSC (Voltage Source Converter)of PV system supplies the PV energy to the grid even under the worst situations of DC offset, solar insolation variation, load unbalancing and voltage swell/sag. The VSC switching losses are reduced using adaptive DC link voltage. The proposed system is modeled and simulated in MATLAB for different odd conditions like solar insolation variation, load unbalancing and voltage sag/swell. Tests are conducted on a prototype built in the research laboratory under various odd states like DC offset and voltage swell/sag, insolation change etc. Performance of the system is found satisfactory and THD’s of the grid currents are found within limits, as recommended by the IEEE -519 standard.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116678630","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A PWM-based sliding mode voltage control of DC-DC boost converter for DC microgrid","authors":"Prashant Singh, J. Lather","doi":"10.1109/POWERI.2018.8704456","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704456","url":null,"abstract":"DC Microgrids are currently replacing AC Microgrids for distributed generation owing to their inherent benefits like the compatible sources, green environment, high efficiency and solidity. The prime responsibility of successful operations of DC Microgrids is to maintain / regulate DC bus voltage within the adequate bounds amid entire functioning conditions. In this paper, a second order SM control is utilized to generate persistent control inputs conceptualized as duty cycles of the dc-dc boost converter (DDBC). This work is designed to supply both DC and AC loads in remote areas where the utility cannot be accessed. Simulations have been accomplished in Simulink settings and results show effectiveness of designed controller.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125890618","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Singh, Sunil Kr. Muwal, Devesh Shukla, S. Singh
{"title":"Model Predictive Driven Volt/VAr Control for Smart Grid Enabled CVR in Active Distribution Network","authors":"S. Singh, Sunil Kr. Muwal, Devesh Shukla, S. Singh","doi":"10.1109/POWERI.2018.8704367","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704367","url":null,"abstract":"Energy conservation through voltage reduction methodology is becoming popular now a days. Enabling of conservation of voltage reduction (CVR) through smart grid technologies makes informal and effective way. However, the integration of distributed energy resources (DERs) in active distribution grids are facing some operational issues. Moreover, the enabling of CVR through conventional schemes are restricted with limited voltage reduction and unable to cope up during intermittency. This paper proposes a model predictive driven Volt/VAR Control (VVC) scheme for smart grid enabled CVR operation in presence of solar photovoltaic (PV) power system. The impact of uncertainty in PV power generation and error in load forecasting are incorporated in predictive model. Scenario based Volt/VAR optimization (VVO) approach is utilized to CVR deployment. The VVO objective is to minimize the voltage deviations between load node voltage and expected CVR voltage. The VVO problem is solved through particle swarm optimization. In order to avoid the voltage violation due to cloud transients, PV inverter-based VAR has been dispatched as a local voltage control. The proposed CVR method is validated on modified IEEE 13 node feeder of radial distribution network. The simulation results revels that the remarkable energy demand and peak load power is reduced through proposed CVR scheme with suitable feeder voltage profile.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115030002","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Consumer Participation Based Scheduling of Microgrid System in Electricity Market","authors":"D. Kumar, Y. P. Verma, R. Khanna","doi":"10.1109/POWERI.2018.8704432","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704432","url":null,"abstract":"The modern technological advancements have made the integration of various renewable energy resources and consumers possible to participate efficiently for better and reliable system operation. Microgrid is one of the most important players of electricity market. In this paper the optimization problem of the microgrid system operating in hybrid electricity market under pool and bilateral contract agreement with demand response of consumers has been investigated. The mathematical model for the system has been developed and solved by CONOPT solver in GAMS optimization software. It shows that the power curtailed by the consumers not only helps in reduction in the overall demand and operating cost of the system but also provide incentives to the consumers to participate in demand response.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"430 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116000401","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Quantitative analysis of IC Engine waste heat utilization in Biogas Sludge Digester","authors":"Prava Gupta, K. Subramanian","doi":"10.1109/POWERI.2018.8704396","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704396","url":null,"abstract":"Sewage sludge is a source for biogas fuel generation. Biogas production is mainly dependent on maintaining of average temperature of the digester $(36^{circ}mathrm{C})$ as it influences the ambient temperature which varies drastically from winter to summer in Delhi. In an extreme winter, biogas production would be minimal or stopped. The biogas has higher octane number that can be used in spark ignition engine for electrical power generation and the waste heat coming from the engine can be used to keep the sludge temperature in winter at the desired level. It is observed from this study that the heat requirement of the digester is met by the waste exhaust heat available (engine coolant) in the engine and still surplus heat is available in engine’s exhaust system. The heating load of the digester is higher in winter than summer. The notable conclusion emerged from this study is that the developed methodology can be used for calculating the heat requirement of a sludge digester for maximum yield of biogas as well as finding out potential surplus heat available in a gas engine fueled with biogas.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129947878","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Ehtesham, Shahzad Ali Rana, Shamshad Ali, M. Jamil
{"title":"Inverter Control Strategy for Enabling Voltage and Frequency Regulation of Grid Connected PV System","authors":"M. Ehtesham, Shahzad Ali Rana, Shamshad Ali, M. Jamil","doi":"10.1109/POWERI.2018.8704429","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704429","url":null,"abstract":"Recent developments in the field of Photovoltaic (PV) technology have resulted in proliferation of PV systems integrated to the grid. In addition to all the cherished benefits of PV power as a renewable source, large scale grid connection has led to unprecedented challenges that are being faced by utilities. One of the most serious issues with greater percentage of PV generation is that as these do not participate in grid frequency or voltage regulation, even a small perturbation in frequency or voltage may result in a disaster leading to total blackout. This paper proposes a novel control algorithm for the PV inverter in order to enhance the performance of grid connected PV system. The incorporated algorithm for inverter control is based on the synchroconverter which offers the advantages of inertia & damping and enables the inverter to regulate the voltage and frequency. Simulated results obtained for the applied control scheme in MATLAB/Simulink platform are presented that shows the inverter capability to respond effectively for the grid side fluctuations.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128502168","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Hybrid Quasi-Z-source DC-DC Boost Converter","authors":"Punit Kumar, M. Veerachary","doi":"10.1109/POWERI.2018.8704416","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704416","url":null,"abstract":"A high voltage gain hybrid quasi-Z-source dc-dc converter (HQZSC) with combination of switched inductor and switched capacitor is proposed. It provides higher voltage gain at low duty ratio, reduced voltage stress across all the components in comparison with traditional impedance source based dc-dc converters. This gain is nearly twice the gain of two switched inductor quasi-Z-source inverter. The operation principle along with steady-state and small-signal analysis of HQZSC is presented. The design guidelines are formulated for inductors and capacitors of the proposed converter. The comparison of HQZSC with other existing converters is also presented. Simulation and experimental results verifies the mathematical analysis of proposed HQZSC.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123873753","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Om Prakash Mahela, Himmani Joshi, Deepak Sharma, Shuvam Sahay
{"title":"Detection of Saturation of Core of Current Transformer Using Combined Feature of Hilbert Transform and Stockwell Transform","authors":"Om Prakash Mahela, Himmani Joshi, Deepak Sharma, Shuvam Sahay","doi":"10.1109/POWERI.2018.8704423","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704423","url":null,"abstract":"This paper presents a technique based on combined application of the Hilbert Transform and Stockwell Transform for the detection of the saturation of the core of the current transformer. The proposed algorithm has been tested in the presence of the resistive inductive as well as capacitive loads. The proposed study is performed in MATLAB/Simulink environment. The simulation results show effectiveness of the proposed algorithm for detection of saturation of the current transformer core.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123897030","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Discrete Linear Phase Based MAF Control for Grid Tied Solar PV System","authors":"S. Pandey, Shailendra Kumar, Bhim Singh","doi":"10.1109/POWERI.2018.8704439","DOIUrl":"https://doi.org/10.1109/POWERI.2018.8704439","url":null,"abstract":"This paper proposes a discrete linear phase based moving average filter (DLPMAF) control with frequency locked loop (FLL) for solar photovoltaic (PV) array tied to a single phase utility grid. The DLPMAF acts as an ideal low pass filter and its cut off frequency, is used by adjusting its window length. The potential of Park's transformation, DLPMAF and FLL are utilized collectively to extract the active power component of nonlinear load connected at PCC (Point of Common Coupling). The proposed system increases the usage of its voltage source converter (VSC). It has the potential of mitigating the harmonics current, improving the DPF (Displacement Power Factor), and thus, reduces reactive power burden on the grid during day time as well as during night when the PV array power generation is not available. Besides, feeding the active power into the utility grid, the proposed control algorithm improves the dynamic response both during irradiance change and dynamics in loads. The total harmonics distortion (THD) of utility current is improved to compliance the limits of the IEEE-519 standard.","PeriodicalId":207265,"journal":{"name":"2018 IEEE 8th Power India International Conference (PIICON)","volume":"144 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123496927","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}