{"title":"Sorting and Balancing Control Algorithms of MMC System","authors":"","doi":"10.1142/9789811213588_0004","DOIUrl":"https://doi.org/10.1142/9789811213588_0004","url":null,"abstract":"","PeriodicalId":203363,"journal":{"name":"HVDC Transmission +1","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126533580","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Miller, B. Vogel, Harry McHugh, Glen Anthony, S. Jones, Mike Grover
{"title":"Background","authors":"K. Miller, B. Vogel, Harry McHugh, Glen Anthony, S. Jones, Mike Grover","doi":"10.1142/9789811213588_0003","DOIUrl":"https://doi.org/10.1142/9789811213588_0003","url":null,"abstract":"Conjugated polymers have emerged as an attractive technology for large-area electronic applications. As organic semiconductors, they can be used to make large-area arrays of diodes or transistors using fabrication techniques developed for polymer coatings, such as spraying and screen-printing. We have demonstrated both neutron and alpha detection using diodes made from conjugated polymers and have done preliminary work to integrate a boron carbide layer into the conventional polymer device structure to capture thermal neutrons. The polymer devices appear to be insensitive to gamma rays, due to their small physical thickness and low atomic number. Background Solid-state neutron detectors would provide a compact, low-power replacement for He tubes typically used for neutron detection. While quite reliable and accurate, He tubes are very expensive and relatively large. The cost of He tubes is the principal reason that they are not widely employed in portal detectors. The cost of a He detector is approximately $40 per square inch. Conductive polymers can be applied to inexpensive substrates such as plastic or metal using simple techniques such as spin coating or spraying. Detectors fabricated from multi-layer conductive polymers offer the promise of less expensive, more versatile neutron detectors than the present He tubes with low gamma sensitivity. Project Energy Deposition and Electrical Charge Generation/Collection To make the solid-state detector being proposed, B was used to capture thermal neutrons, resulting in emission of an alpha particle that can then generate electron-hole pairs to be detected by the polymer diode. Calculations show that a B layer thickness of 1.5 μm presents an optimum thickness for capture of the neutron while ensuring a significant chance of an alpha escape with substantial energy intact. For a layer of this thickness, there is approximately a 3% probability of capturing a thermal neutron. See Figure 1 for a theoretical plot of alpha energy vs. boron thickness. For this discussion, we shall analyze a 30-μm-thick polymer detector. At this thickness, almost all of the 1.5 MeV alpha energy will be trapped in the polymer. The ionization energy of this polymer is approximately 5 eV, leading to one electron-hole pair created for each 15 eV deposited (Radiation Measurement, 2007). In the case of a 1.5-MeV alpha, this equates to the creation of approximately 100,000 pairs, carrying a charge of 1.6 x 10 coulombs. If all the electron-hole pairs generated by the alpha particles could be collected, the single-event pulses from the 30-μm polymer detector should be about 80 mV, well above the peak noise. Figure 2 shows a display of the waveform obtained from an alpha capture in a 30-μm-thick polymer detector. The peak of the waveform is only about 15 mV (negative direction). The baseline noise peaks can be seen to be less than 7 mV. The low value of the peak voltage implies that only about 20% of the charge generated from the alpha ","PeriodicalId":203363,"journal":{"name":"HVDC Transmission +1","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127777469","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Introduction to High Voltage Direct Current (HVDC) Technology","authors":"","doi":"10.1142/9789811213588_0001","DOIUrl":"https://doi.org/10.1142/9789811213588_0001","url":null,"abstract":"","PeriodicalId":203363,"journal":{"name":"HVDC Transmission +1","volume":"214 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115504602","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Protection and Insulation of MMC","authors":"","doi":"10.1142/9789811213588_0009","DOIUrl":"https://doi.org/10.1142/9789811213588_0009","url":null,"abstract":"","PeriodicalId":203363,"journal":{"name":"HVDC Transmission +1","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115315814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}