{"title":"A novel approach to electromagnetic torque identification problem in current-fed AC drive","authors":"Z.H. Kulski","doi":"10.1109/PESC.1994.349651","DOIUrl":"https://doi.org/10.1109/PESC.1994.349651","url":null,"abstract":"A novel physical approach to the electromagnetic torque identification problem for the current-fed AC motor is presented. The physical approach is based on an identification model of the three-phase bridge converter in the current source configuration, and uses a mathematical model of the AC motor at the asymmetric power supply. The identification procedure uses the measurement and processing of the electrical terminal values of the inverter without participation of the drive motor parameters. The effectiveness of this identification procedure is illustrated by the laboratory test results.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"89 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124193400","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Vector control of synchronous reluctance motors including stator-iron loss with on-line parameter measurement","authors":"Y. Tomori, T. Senjyu, K. Uezato","doi":"10.1109/PESC.1994.349689","DOIUrl":"https://doi.org/10.1109/PESC.1994.349689","url":null,"abstract":"This paper describes the vector control of a synchronous reluctance motor with on-line parameter measurement based on the voltage equation taking account of the stator iron loss. The vector control is achieved by using nonlinear state feedback to eliminate the interference of d-q axes through the equivalent iron loss resistance in transient conditions. The parameters of the vector controller are adjusted to achieve the vector control of synchronous reluctance motors in the case that machine parameters have variations.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124418669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new current fed type PWM inverter system using instantaneous vector control","authors":"Y. Minamoto, T. Ohnishi","doi":"10.1109/PESC.1994.349737","DOIUrl":"https://doi.org/10.1109/PESC.1994.349737","url":null,"abstract":"This paper proposes a new PWM strategy of the current fed type inverter based on instantaneous vector control. In this system, the output voltages can be obtained directly by feedback control of the instantaneous vector. So, the proposed inverter system has a simple control circuit, fast response, and robustness against disturbances. In addition to these, it is possible that pure sinusoidal waveforms of load currents may be achieved by reducing the ripple of the output voltages under the inductive load.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"254 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114445499","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Course and laboratory instructions in power electronics","authors":"I. Batarseh","doi":"10.1109/PESC.1994.373861","DOIUrl":"https://doi.org/10.1109/PESC.1994.373861","url":null,"abstract":"In this paper, the topic of undergraduate and graduate education in the field of power electronics is presented. Based on several surveys conducted in recent years by the Power Engineering Education Resources Subcommittee, the collected data is closely examined in order to shed some light on the educational aspects in the field of power electronics. Suggested undergraduate and graduate curricula in power electronics along with key course content are presented. Moreover, the importance of hardware laboratory and Pspice simulation as supporting facilities for effective power electronics education are also addressed.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114609044","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Minimisation of current crowding during turn-off of power GTO devices","authors":"T. K. Lee, Y.C. Liang","doi":"10.1109/PESC.1994.349697","DOIUrl":"https://doi.org/10.1109/PESC.1994.349697","url":null,"abstract":"The maximum controllable anode current is influenced by the current crowding phenomenon observed in GTO thyristors during turn-off. This phenomenon initiates: (1) formation of the current filament with a density much higher than its surrounding and leads to the localised thermal instability; and (2) conductivity modulation at the conduction channel causing a nonuniform electric field distribution within the depletion layer and resulting in an early punchthrough breakdown. In this paper, device parameters are optimised by detailed two-dimensional device simulations to minimise the current crowding and at the same time to maintain a low forward voltage drop and short turn-off time. By doing so, the localised thermal stress can be reduced and a more uniform electric field distribution is obtained.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117028609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Stability analysis of a switched mode inverter using 'Cuk converters","authors":"Chin-Yuan Hsu","doi":"10.1109/PESC.1994.373766","DOIUrl":"https://doi.org/10.1109/PESC.1994.373766","url":null,"abstract":"A four-quadrant DC to AC switched-mode inverter, using a 'Cuk power converter, is analyzed. Also, a feedback loop is used to regulate the output voltage and produce purely sinusoidal voltage. First, a small signal dynamic model of the inverter is derived using the state-space averaging method. Then, based on this model, three approaches are used for the stability analysis: (1) frequency domain analysis. A Bode diagram is used to design the compensator and to determine the relative stability and bandwidth of the closed-loop system; (2) root locus analysis. According to the perturbation of the duty cycle the root loci are plotted. Using these plots, the behavior of the system is investigated; and (3) step response. This test is used to illustrate the relative stability and bandwidth of the system. Finally, some computer simulation and experimental results are presented.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123664449","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Nishimura, T. Eguchi, K. Hirachi, Y. Maejima, K. Kuwana, M. Saito
{"title":"A large air gap flat transformer for a transcutaneous energy transmission system","authors":"T. Nishimura, T. Eguchi, K. Hirachi, Y. Maejima, K. Kuwana, M. Saito","doi":"10.1109/PESC.1994.373855","DOIUrl":"https://doi.org/10.1109/PESC.1994.373855","url":null,"abstract":"A flat transformer for a full-bridge series resonant DC/DC power converter which transfers several W of power across a large, variable human skin gap has been designed and built, The power converter can power a rechargeable cardiac pacemaker battery through intact skin by utilizing a transformer with an air gap of 0.5 to 1.5 cm between the primary and the secondary windings. A ferrite pot core is used for the primary winding. The secondary winding with a flat amorphous core would be implanted under the skin, and the primary would be placed on top of the secondary outside the body.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116804390","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Improved power system performance using inverter based resonant switched compensators","authors":"K. Hoffman, G. Ledwich","doi":"10.1109/PESC.1994.349729","DOIUrl":"https://doi.org/10.1109/PESC.1994.349729","url":null,"abstract":"Resonant soft switched high power inverter based static VAr compensators (ISVCs) can provide higher switching frequencies than present hard switched ISVCs. This allows a faster transient response so that the ISVC can also be used simultaneously as an active filter to reduce supply harmonics and random flicker caused by arc furnaces. System subsynchronous resonance compensation can be implemented at the same time and precise injected current control will result in faster damping of alternator torsional mode oscillations than is presently possible.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125742774","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Robust speed control of DC servo motor based on Lyapunov's direct method","authors":"T. Senjyu, H. Kamifurutono, K. Uezato","doi":"10.1109/PESC.1994.349687","DOIUrl":"https://doi.org/10.1109/PESC.1994.349687","url":null,"abstract":"The speed control ability of a DC servo motor is affected by parameter variations and disturbance torque. In this paper, the robust speed control method of a DC servo motor with a disturbance torque observer is proposed, in which the disturbance torque observer is used for the compensation of parameter variations and disturbance. The influence of estimation error is restrained by feedback gain based on Lyapunov's direct method. Also, the current tracking control is very important, since motor torque is generated by the armature current. The robust current control method of a voltage source PWM inverter with a disturbance voltage observer is presented; the armature current is controlled to be exactly equal to the reference current under the variations of load parameters and operating conditions.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125031095","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A three-phase current-source type PWM rectifier with feed-forward compensation of input displacement factor","authors":"N. Zargari, G. Joós","doi":"10.1109/PESC.1994.349708","DOIUrl":"https://doi.org/10.1109/PESC.1994.349708","url":null,"abstract":"Three-phase current-source type PWM rectifiers are often used as the front-end power converter unit in utility-interfaced systems. Due to the input filter (needed for current harmonic suppression), the input displacement factor is less than unity. It varies with the rectifier operating point and may result in unacceptable low values. In this paper, a new control method is proposed to achieve unity displacement factor independent of the load conditions. The proposed method controls the phase shift of the input currents in a feedforward fashion. The modulating signals are phase shifted according to the rectifier operating point to always result in near unity input displacement factor. The compensation scheme makes use of a DC current loop and the standard DC voltage regulation loop to produce the modulating signals with the required phase shift. As a result, the control circuitry does not require additional sensors. The PWM pattern is generated online, which results in fast response to transients. The rectifier is analyzed and design equations are derived. A design example is given and theoretical considerations are verified through simulation and by experimental results obtained on a 1 kVA laboratory prototype.<<ETX>>","PeriodicalId":202161,"journal":{"name":"Proceedings of 1994 Power Electronics Specialist Conference - PESC'94","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128369325","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}