Proceedings of Industrial and Commercial Power Systems Conference最新文献

筛选
英文 中文
On the exact computation of some typical and dynamic phenomena in power networks including iron-core transformers 铁芯变压器等电网中一些典型动态现象的精确计算
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303554
K. Abdul-Rahman, M. Saied
{"title":"On the exact computation of some typical and dynamic phenomena in power networks including iron-core transformers","authors":"K. Abdul-Rahman, M. Saied","doi":"10.1109/ICPS.1994.303554","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303554","url":null,"abstract":"This paper begins with a brief review of the available literature dealing with the exact modelling of iron-cored coils and transformers. Taking into account the simulation accuracy as well as the required computational burden, the model proposed by Ewart (1986) was chosen to study two important issues related to nonlinear cores: the overvoltages resulting from nonvertical chopping of core or transformer magnetizing currents; and the strongly distorted current, voltage and flux waveforms appearing in systems including linear as well as nonlinear inductances.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125805596","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrical impact of a NUG under 5 MW rating when connected to a distribution feeder with various transformer connections 额定功率低于5mw的NUG与各种变压器连接的配电馈线连接时的电气影响
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303588
D. Kunda, E. Neudorf, N. Perris, L.M. Szeto, D.V. Krause
{"title":"Electrical impact of a NUG under 5 MW rating when connected to a distribution feeder with various transformer connections","authors":"D. Kunda, E. Neudorf, N. Perris, L.M. Szeto, D.V. Krause","doi":"10.1109/ICPS.1994.303588","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303588","url":null,"abstract":"This paper describes electrical impact of nonutility generators (NUG) under 5 MW rating when connected to a distribution feeder. A number of problems are examined including line-to-ground fault level, overvoltage conditions, effect of harmonics, single-phase resonance and transformer backfeed with one phase open. These problems are examined with four different transformer connections. Protection requirements for various supply conditions are discussed. Two actual events involving transformer failure and starting problems are described under operating experiences.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121805077","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Aspects of overcurrent protection for feeders and motors 馈线和电机的过流保护
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303583
E. Schweitzer, S. Zocholl
{"title":"Aspects of overcurrent protection for feeders and motors","authors":"E. Schweitzer, S. Zocholl","doi":"10.1109/ICPS.1994.303583","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303583","url":null,"abstract":"This paper discusses the coordination of the characteristics and the backup and redundancy possible with microprocessor relays. The paper reviews the application of negative sequence overcurrent characteristics for unbalanced protection in motors and also covers the rules for coordination of negative sequence characteristics to provide sensitive phase to phase protection in feeders. The paper also covers reset characteristics and the requirements for stator and rotor thermal protection of induction motors.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128890364","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Power factor and harmonic compensation in industrial power systems with nonlinear loads 含非线性负荷工业电力系统的功率因数与谐波补偿
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303580
R. Kingston, Y. Baghzouz
{"title":"Power factor and harmonic compensation in industrial power systems with nonlinear loads","authors":"R. Kingston, Y. Baghzouz","doi":"10.1109/ICPS.1994.303580","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303580","url":null,"abstract":"Industrial power systems are often characterized as large consumers of reactive power and significant generators of harmonics because most of the load is generally composed of induction motors and static power converters. Consequently, this article analyzes a typical power system configuration where is it desirable to install power factor capacitors and tuned harmonic filters for reactive power compensation and harmonic control. The resonant conditions for a given power factor correction or a harmonic frequency are determined directly from the roots of a quadratic expression. This formulation also allows a quick evaluation of power factor range with excessive harmonic levels, as well as effects of tuned reactors on the resonant frequencies.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131035393","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Grounding/earthing electrode studies. 2 接地/接地电极研究。2
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303569
R. S. Howard, D. Zipse
{"title":"Grounding/earthing electrode studies. 2","authors":"R. S. Howard, D. Zipse","doi":"10.1109/ICPS.1994.303569","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303569","url":null,"abstract":"The paper presents a study on surge arrestor grounding electrodes comparing different grounding electrodes and various backfill materials. This report presents the procedures and results for the first three months of the eighteen month study.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"115 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124130026","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Electrical power system reliability case studies for water and wastewater treatment facilities 水和废水处理设施电力系统可靠性案例研究
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303555
G.J. Ratasky, J. Shubik
{"title":"Electrical power system reliability case studies for water and wastewater treatment facilities","authors":"G.J. Ratasky, J. Shubik","doi":"10.1109/ICPS.1994.303555","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303555","url":null,"abstract":"This paper identifies key issues of plant-wide electrical reliability evaluations and design for water and wastewater treatment facilities. The presentation of key issues is based on extensive experience represented in case studies involving system configurations, power quality, standby/emergency power, electric utility service arrangements, and other pertinent issues. In addition, these case studies address EPA and California Title 22 requirements, all with regard to reliable design of electrical systems.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"504 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116553060","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Transient performance of substation structures and associated grounding systems 变电站结构及相关接地系统的暂态性能
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303567
F. Dawalibi, W. Xiong, Jinxi Ma
{"title":"Transient performance of substation structures and associated grounding systems","authors":"F. Dawalibi, W. Xiong, Jinxi Ma","doi":"10.1109/ICPS.1994.303567","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303567","url":null,"abstract":"When lightning strikes an electric substation, large currents generated by the stroke flow in the aboveground structures and grounding system and dissipate in the soil. The electromagnetic fields generated by such high currents may cause damage to equipment and may be dangerous to personnel working nearby. In this paper, the frequency and time domain performance of a substation subjected to a lightning strike is described and discussed. The computed scalar potentials, electric fields and magnetic fields are presented graphically as a function of spatial coordinates, as a function of time and as a function of both. Two cases are considered. The first case examines the substation grounding system only, while the second case includes an aboveground structure as well. It is believed that the results of the second case have not been published before. A double exponential lightning surge current is injected at one corner of the substation. The response of the grounding system to the frequency domain electromagnetic spectrum of this signal is computed by a frequency domain electromagnetic field analysis software package. The temporal and spatial distributions of the electromagnetic fields inside and near the substation are obtained by an inverse Fourier transformation of all these responses. The presence of a soil with an arbitrary resistivity and permittivity is accurately taken account. Analysis sheds some new light on understanding of the effects which take place at the higher frequencies.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128805541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 54
Quick evaluation of voltage surge in electrical power systems 电力系统中电压浪涌的快速评估
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303573
L. Yu
{"title":"Quick evaluation of voltage surge in electrical power systems","authors":"L. Yu","doi":"10.1109/ICPS.1994.303573","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303573","url":null,"abstract":"The lattice diagram has been widely recognized and adopted to analyze the voltage surges produced at a particular location in an electrical system. These transient surges are caused by traveling waves induced by lightning strikes or switching operations. The lattice diagram can be used effectively, but the required computations are tedious. A simplified approach for computing induced voltage surges based on mathematical derivation is presented. This method permits a quick evaluation of both an initial and crest surge magnitude and wave shape based on a given incoming surge and the surge impedances of the electrical elements involved. Sample calculations from the lattice diagram and the proposed quick evaluation are compared.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125441982","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Short circuit currents of the SEPTA's traction power distribution system SEPTA牵引配电系统的短路电流
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303548
R. Natarajan, M. Lopez-Lopez, R. M. Bucci, T.A. Kneshke, J. Hong, W. Naqvi
{"title":"Short circuit currents of the SEPTA's traction power distribution system","authors":"R. Natarajan, M. Lopez-Lopez, R. M. Bucci, T.A. Kneshke, J. Hong, W. Naqvi","doi":"10.1109/ICPS.1994.303548","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303548","url":null,"abstract":"The Southeastern Pennsylvania Transportation Authority (SEPTA) owns and operates an electrified system of commuter rail lines in Philadelphia and its suburban areas. The traction power supply system is of an autotransformer type and is supplied from three static frequency converters each rated at 15 MVA. The system trolley circuits are supplied at 12 kV, 25 Hz and the feeders are supplied at 24 kV, 25 Hz. The feeder and the trolley circuits are connected through autotransformers at substations spaced along the route at appropriate intervals and the rails provide the ground return circuit. The advantage of the autotransformer system is that the traction power is being distributed effectively at 36 kV while it is being utilized at only 12 kV. Since conventional short circuit analyses do not account for the feedback currents through the autotransformers, a novel method for calculation of the fault currents was developed using the Electromagnetic Transients Program (EMTP). Using this method, feeder to trolley, feeder to ground, and trolley to ground fault currents were calculated. This method is readily adaptable to many different feeder, trolley and track trolley configurations.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129615818","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Simulation of DC power distribution systems 直流配电系统仿真
Proceedings of Industrial and Commercial Power Systems Conference Pub Date : 1994-05-01 DOI: 10.1109/ICPS.1994.303572
E. Zhou, A. Naslé
{"title":"Simulation of DC power distribution systems","authors":"E. Zhou, A. Naslé","doi":"10.1109/ICPS.1994.303572","DOIUrl":"https://doi.org/10.1109/ICPS.1994.303572","url":null,"abstract":"Direct current (DC) power distribution systems have been extensively used in nuclear power plants and transit systems. The major concern of DC system studies is the voltage and voltage drop at load buses. A Newton-Raphson method based DC load flow algorithm and a DC system simulation package have been developed and reported in this paper. DC generators, batteries, AC/DC rectifier converters and constant power, constant current, constant resistance loads can be considered in the simulation. Time-varying and moving loads can also be simulated.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"10 9","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131776571","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信