{"title":"USING A DISCRETE ELEMENT/FINITE ELEMENT APPROACH TO MODEL IMPACT OF A RIGID PROJECTILE ON CONCRETE AND REINFORCED CONCRETE TARGETS","authors":"A. Antoniou, L. Daudeville, P. Marin, S. Potapov","doi":"10.2495/SUSI180011","DOIUrl":"https://doi.org/10.2495/SUSI180011","url":null,"abstract":"This paper presents a mixed numerical modelling able to predict the response of reinforced concrete (RC) structures under extreme loadings such as missile impacts. Concrete is modelled using cohesive rigid spherical discrete elements (DE), while steel reinforcement is represented by beam-like finite elements (FE). Concrete-steel DEM/FEM bond model calibrated on pull-out tests is used, which ensures forces transmitting between steel and concrete. This approach is validated through the simulation of two experiments (edge-on-impact test and drop-weight impact) involving hard impacts on plain concrete and a large RC beam. The numerical results are presented and their comparison with the experimental data is discussed.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"142 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116532597","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A NUMERICAL ANALYSIS ON FLAT-SHAPED RC BEAMS UNDER FALLING-WEIGHT IMPACT LOADING","authors":"Dandan Zheng, M. Komuro, Tomoki Kawarai, N. Kishi","doi":"10.2495/SUSI180151","DOIUrl":"https://doi.org/10.2495/SUSI180151","url":null,"abstract":"In this study, in order to establish a rational numerical analysis method for RC structures under fallingweight impact loading, a 3D elasto-plastic dynamic response analysis was conducted for flat-shaped RC beams. The beams have a rectangular cross section of 150 × 450 mm (height × width) and a clear span length of 2.0 m, which are an approximate one-fifth scale of the roof slab of existing RC rockfall protection galleries. Falling-weight impact tests were conducted by dropping a 300 kg steel weight onto the mid-span of the beam. Here, an influence of the element size of FE analysis on numerical simulation dynamic responses of the flat-shaped RC beams was investigated by dividing the intervals of stirrups (125mm) into 2, 5, 10 elements, in which these element sizes were 62.5 mm, 25 mm, 12.5 mm, respectively. An appropriate element size was determined comparing with the experimental results of the impact and reaction forces, the deflection at the loading point, and the crack patterns occurred on surfaces of the beam after the experiment. The results obtained from this study were as follows: 1) the time histories of the dynamic responses of the flat-shaped RC beams can be better simulated using a 25 mm of element size in span direction; and 2) maximum and residual deflections can be better predicted in spite of the magnitude of the falling height of the weight; 3) crack patterns of the RC beams can be better simulated applying the proposed numerical analysis method.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121678025","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"MODELING THE IMPACT OF EXPLOSIONS IN ENCLOSED SPACES USING DISCONTINUOUS BOUNDARY ELEMENTS AND FINITE VOLUME METHODS","authors":"P. Procházka, Š. Pešková","doi":"10.2495/SUSI180051","DOIUrl":"https://doi.org/10.2495/SUSI180051","url":null,"abstract":"This paper is aimed at studying the influence of loading due to shock (strike) waves in an enclosed space; underground parking is a typical example. The problem which is to be solved is divided into the description of motion and pressure in the air and in the solid phase, separately; the interaction of the effects arising in the air and the solid phase are concentrated along the boundary interface between the two media. As the free hexagon method (discontinuous boundary element method) has proved to be well applicable in solving nonlinear problems in structures, it is also used, slightly adjusted, here. In order to connect both mediums (structure, air), the gas-dynamics in the air is described, based on equations of conservations, by a simplified finite volume elements, their shapes are also hexagonal, to be in geometrical compliance with the rock and structure. The hexagonal shapes are arbitrarily, i.e. not necessarily honey combs, like mostly used in connection with finite elements. Note that such a shape of elements complies with the requirements for the finite volume method. The BEM describes the elasticity, or nonlinear behavior inside of each hexagonal element of the solid phase, while the mechanical behavior on the interfaces between the adjacent elements obeys the laws of MohrCoulomb localized damage.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127724491","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"ANALYTICAL INVESTIGATION OF SEISMIC PERFORMANCE OF MASONRY WALLS STRENGTHENED WITH STRAIN HARDENING FIBER REINFORCED GEOPOLYMER MATRIX","authors":"Elnara Satekenova, Dichuan Zhang, J. Kim, K. Wan","doi":"10.2495/SUSI180211","DOIUrl":"https://doi.org/10.2495/SUSI180211","url":null,"abstract":"Strain hardening fiber reinforced geopolymer matrix, termed here as strain hardening material, is being proposed as a new seismic retrofitting material. Seismic behavior of the masonry walls with and without the strain hardening material was evaluated through finite element simulations in this paper. The finite element simulation was conducted on a masonry wall model with smeared crack material properties. The effectiveness of the strain hardening material for enhancing the seismic capacity of the masonry wall was evaluated through pushover analyses. Several parameters are considered in the pushover analysis including thickness and mechanical properties of the strain hardening material, wall geometries and loading directions. The force-displacement response obtained from the pushover analysis was used to develop a simplified multi-degree spring model. Nonlinear dynamic time history analyses were conducted using the spring model to evaluate the seismic demand of masonry structures strengthened with the strain hardening material. From the simulation results, it has been found that the strain hardening material can significantly improve the strength and ductility of the masonry wall under earthquakes. Design recommendations are made for retrofitting masonry structures using the proposed strain hardening material.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132068876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"EXPERIMENTAL TESTING OF REINFORCED CONCRETE SLABS RETROFITTED WITH CFRP AND MECHANICAL ANCHORS","authors":"G. Pezzola, L. Stewart","doi":"10.2495/SUSI180171","DOIUrl":"https://doi.org/10.2495/SUSI180171","url":null,"abstract":"The ongoing presence and persistence of terrorist groups is a perpetual threat that emphasizes the urgency to strengthen and retrofit any structural vulnerabilities, especially vulnerabilities that when exploited could lead to catastrophic damage of expensive infrastructure or loss of life. To avoid these losses, the application of fiber-reinforced polymer (FRP) laminates as a retrofit on reinforced concrete (RC) structural elements has been proven to increase the blast resistance. There have been few studies, however, on the anchorage behavior in large-scale RC systems retrofitted with FRP subjected to blast. To bridge this gap, two different mechanical anchorage techniques for concrete structures using carbon fiber-reinforced polymer (CFRP) layers were subjected to explosive loading to investigate system behavior with the different mechanical anchorage retrofits: a steel strap retrofit system and a smaller steel plate retrofit system. The experimental program utilized a hemisphere C4 charge and pressures were recorded. The performance of the two blast retrofits were evaluated and compared in terms of the displacements of the slab systems and associated failure modes.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131048159","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A SCALED AIR BLAST MODEL FOR HIGH ALTITUDES","authors":"Z. Wang, Jun Liu, X. Gong","doi":"10.2495/SUSI180041","DOIUrl":"https://doi.org/10.2495/SUSI180041","url":null,"abstract":"Based on Sachs scaling, an engineering computational model on air blast wave at high altitudes is presented in this paper. The model is built on analysis from numerical simulated pressure time data of shock wave in air. The model describes the peak overpressure, impulse, and typical time of the shock wave with new parameters. Comparison of pressure, density and velocity configuration for the different altitudes shows that the present engineering model can give consistent results with the numerical code. At last the scaled peak overpressure and the scaled impulse figure for the different altitudes are given for convenience of engineering application.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114851280","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Geraschenko, A. S. Grishin, Nataly Igorevna Gartung
{"title":"APPROACHES FOR THE CALCULATION OF RAYLEIGH DAMPING COEFFICIENTS FOR A TIME–HISTORY ANALYSIS","authors":"V. Geraschenko, A. S. Grishin, Nataly Igorevna Gartung","doi":"10.2495/susi180201","DOIUrl":"https://doi.org/10.2495/susi180201","url":null,"abstract":"Direct numerical integration of the differential equations of motion is widely used to analyse a structure behaviour under the action of seismic loads. Whatever the reason is, an engineer is faced with a problem of calculating Rayleigh damping coefficients. In the direct method, a damping matrix is formed by a linear combination of the mass and stiffness matrices multiplied by Rayleigh coefficients and respectively. To calculate the damping coefficients and , an engineer need two circular frequencies (1, 2) defining the frequency range which contribute to the response of the structure and a damping ratio (). As far as one knows, Rayleigh damping coefficients have significant impact on the structure response to seismic loads therefore the design values of the damping coefficients should be justified. When the modal superposition method is used, the engineer is able to account accurately for damping, because one can use a material-damping ratio (fraction of critical damping). In this paper, the authors carry out time-history analyses of a fixed base building subjected to seismic loads by the modal superposition and direct integration methods. In the direct method, damping properties of the building are taken into account with Rayleigh damping coefficients calculated on different approaches. The building response to seismic loads are compared by the response spectra calculated upon the timehistories retrieved from the modal superposition and direct methods. The least conservative approach of calculating damping coefficients is proposed for the time-history analysis with Rayleigh damping.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121698485","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Kathryn Sanborn, Noel Flores, R. Gentry, L. Stewart
{"title":"TOWARDS A SINGLE DEGREE OF FREEDOM (SDOF) MODEL FOR PREDICTING BLAST PERFORMANCE OF CROSS-LAMINATED TIMBER","authors":"Kathryn Sanborn, Noel Flores, R. Gentry, L. Stewart","doi":"10.2495/SUSI180121","DOIUrl":"https://doi.org/10.2495/SUSI180121","url":null,"abstract":"There is a need for renewable building materials that are suitable replacements for conventional building materials such as steel and concrete. Cross-laminated timber (CLT) is a relatively new composite timber product with increasing use and interest in North America due to its renewable properties. Due to the unique environmental and mechanical properties of CLT, the possibility for rapid construction, and familiarity with the base material (timber), it follows that CLT may be promising for use in temporary military housing. In order to be a material for consideration in temporary military structures, CLT must be evaluated for force protection (i.e. blast effects). To investigate this possibility, the authors used data from live blasting testing conducted by WoodWorks at the US Air Force Civil Engineer Center on multiple two-storey, single-bay CLT structures. A single degree of freedom model (SDOF) was used in conjunction with the shear analogy method to predict the behavior of the CLT structures in the elastic regime. Through the CLT SDOF model, the paper highlights the necessity for further testing of CLT under blast loadings to quantify the effects of shear, boundary conditions, dynamic strength, and other properties.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132893699","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"EARTHQUAKE RESPONSE OF AN OPEN-TYPE WHARF WITH A PNEUMATIC CAISSON FOUNDATION","authors":"D. Shibata, T. Nagao","doi":"10.2495/SUSI180191","DOIUrl":"https://doi.org/10.2495/SUSI180191","url":null,"abstract":"ABSTRACT An open-type wharf with a pneumatic caisson foundation has strong earthquake resistance because of its high rigidity. Construction of wharves with stronger seismic resistance and a larger planned depth is indispensable to accommodate ever-increasing larger vessels. Considering this trend and strong earthquake resistance, open-type wharves with a pneumatic caisson foundation will be widely applied in the future. Consequently, it is necessary to establish a practical design method of the wharf. Existing practical earthquake resistant design methods for an open-type wharf with a steel pipe pile foundation follow the below-mentioned procedure: (i) To calculate acceleration response spectra at the position of 1/β below the virtual ground surface by means of a one-dimensional earthquake response analysis of the ground. Here, the virtual ground surface means a 1/2 gradient face in between the slope and the seabed. β is a pile characteristic value; (ii) To calculate response acceleration corresponding to the natural period of the wharf. Here, the damping constant is 20%; (iii) To divide the response acceleration by gravity acceleration to obtain seismic coefficients; and (iv) To calculate inertial force using the seismic coefficients and verify the stability of the structure. To follow the design procedure described above may be appropriate. However, the difference in the rigidity of foundation between the two structural types should be considered. The authors conducted two-dimensional finite element earthquake response analyses, modelling both open-type wharves with pneumatic caissons and soil layers, and discussed their earthquake responses. As a result of this study, the earthquake response of the wharf with pneumatic caissons is different from that on a steel pipe pile foundation. The optimum evaluation positions of acceleration response spectra have proved to be foundation bottom levels, and the optimum damping constant for the evaluation of response acceleration to range from 5–20%.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"104 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133363277","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"ATTENUATION OF BLAST EFFECTS FROM UNDERWATER EXPLOSIONS IN BUILT STRUCTURES","authors":"C. Roller, A. Stolz","doi":"10.2495/SUSI180031","DOIUrl":"https://doi.org/10.2495/SUSI180031","url":null,"abstract":"The paper provides reassessment and new design of shock-absorbing retrofit systems for water-filled ducts based on experimental investigations. In a first step, tests were conducted in a 2.0-meter-high circular cylinder tank made of steel. The axisymmetric geometry of the tank offered an ideal environment for validation of the theoretical work. A number of parameter variations (water level, charge location, retrofit system) provided further insight into potential and limitations of the concepts. In a second step, a reinforced concrete shaft plus relief pool will used for scaled experiments. This will serve for a realistic representation of the phenomena in a water duct and thus enabled investigations of more complex processes (multiple reflections, tunnel effect) and practical proof of concept. Regarding retrofit systems, three concepts have been identified with respect to their impedances mismatch with water: a single layer concept made of polyvinyl chloride (PVC) foam and polyurethane (PUR) foam respectively as well as a bubble curtain. The significant potential of all investigated measures has been confirmed during the test campaign. Maximum reduction of peak-overpressure down to 0.3% for PVC, 3.2% for PUR and 1.6% for the bubble curtain compared to unmitigated set-up (100%) have been determined. Thus, the developed concepts have been successfully validated and may be applied to all areas where safety and security of structures filled with or covered by fluids. Examples include among others power plants, chemical industry, port facilities and canal constructions.","PeriodicalId":196151,"journal":{"name":"Structures Under Shock and Impact XV","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132751166","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}