10th International Conference on Conduction and Breakdown in Dielectric Liquids最新文献

筛选
英文 中文
Flow-induced electrification and partial discharge measurements in energized transformer duct structures 通电变压器管道结构的流致带电和局部放电测量
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202893
M. Lee, J. K. Nelson
{"title":"Flow-induced electrification and partial discharge measurements in energized transformer duct structures","authors":"M. Lee, J. K. Nelson","doi":"10.1109/ICDL.1990.202893","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202893","url":null,"abstract":"Physical models which are representative of the materials, construction, and dimensions of power transformer duct structures have been fabricated for both core- and shell-form designs. Electrification characteristics have been documented as a function of the parameters of practical interest and the results obtained have the general character of those found in earlier studies. However, partial discharges have only been detected under worst-case conditions for the blocking structure associated with the shell-form configurations which generate more charge than the corresponding conditions in the core-form construction. The studies have quantified electrification in realistic models characteristic of actual transformers and could be used as a guide to provide estimates of charge levels in energized transformer structures.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121712038","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Ester fluid Midel 7131 as PCB-substitute for distribution transformers 酯流体middel 7131作为配电变压器的pcb替代品
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202956
H. Borsi
{"title":"Ester fluid Midel 7131 as PCB-substitute for distribution transformers","authors":"H. Borsi","doi":"10.1109/ICDL.1990.202956","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202956","url":null,"abstract":"The electric and dielectric behavior of ester fluid considered as a substitute for PCB is examined. After a short description of the insulating fluid, the authors consider the influence of temperature differences and aging condition of the insulation on the breakdown behavior of the fluid-paper combined dielectric. Furthermore, a comparison of the breakdown and aging behavior of cellulose-ester impregnated and aramid-ester impregnated insulating materials is given. Finally, the influence of partial discharge prestressing on the breakdown behavior of the fluid-paper combined dielectric is shown.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123765887","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
The correlation between partial discharges (PD) and gassing in insulating liquids 绝缘液体中局部放电(PD)与气体的关系
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202960
H. Borsi, U. Schroder
{"title":"The correlation between partial discharges (PD) and gassing in insulating liquids","authors":"H. Borsi, U. Schroder","doi":"10.1109/ICDL.1990.202960","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202960","url":null,"abstract":"The authors report on investigations performed to determine the relationship between PD parameters and the dissolved gas generated by partial discharges in mineral-based oil. The PD activity of mineral-based oil is shown to depend upon many parameters, including the influence of the standing time between the filling of the test vessel and the switching of the test voltage as well as the voltage's magnitude on the PD activity. Regarding the gassing behavior, several hydrocarbons show a linear (increasing) dependence upon the integral PD parameters. By contrast the amount of oxygen decreases with increasing PD loading. Calculation of gas ratios indicates that the relation between hydrogen and methane is a sensitive indicator of PD activity in mineral-based oil.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125634886","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Electrodynamic transport of liquid 液体的电动输送
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202910
M. Bologa, I.A. Kozhukhar, A. Malakhov, I. Kozhevnikov
{"title":"Electrodynamic transport of liquid","authors":"M. Bologa, I.A. Kozhukhar, A. Malakhov, I. Kozhevnikov","doi":"10.1109/ICDL.1990.202910","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202910","url":null,"abstract":"Theoretical and experimental results on single-stage and multistage electrohydrodynamic pumps are discussed. Investigations of their head-delivery characteristics, efficiency, and service life depending on the geometric parameters of the pump, field, and working liquid parameters are examined.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121758066","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The effect of heating and EHD events on breakdown in water 加热和EHD事件对水中击穿的影响
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202972
I. M. Gavrilov, V. R. Kukhta, V. Lopatin
{"title":"The effect of heating and EHD events on breakdown in water","authors":"I. M. Gavrilov, V. R. Kukhta, V. Lopatin","doi":"10.1109/ICDL.1990.202972","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202972","url":null,"abstract":"Prebreakdown events in a nonuniform field in water were studied experimentally. Branching dendrites propagating with subsonic velocities and thin supersonic plasma channels were observed to form. It was found that, in deionized water, heating has no effect on the initiation and development of discharge channels. It is further shown that the EHD (electrohydrodynamic) events for discharge times of 10/sup -4/ to 10/sup -3/ affect the development of slow dendrites without changing the discharge dynamics.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134080772","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Stability of suspensions of ferroelectric BaTiO/sub 3/ particles in hydrocarbon carrier liquids 铁电BaTiO/ sub3 /颗粒悬浮液在烃类载体液体中的稳定性
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202945
J. Muller, J. Abendroth, K. Barner
{"title":"Stability of suspensions of ferroelectric BaTiO/sub 3/ particles in hydrocarbon carrier liquids","authors":"J. Muller, J. Abendroth, K. Barner","doi":"10.1109/ICDL.1990.202945","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202945","url":null,"abstract":"The stability of suspensions of ferroelectric (BaTiO/sub 3/) nm-particles, using heptane as carrier liquid and oleic acid as stabilizer, is investigated by means of electrooptic Kerr rotation and optical transmittance. On suspension up to 0.006 solid volume fraction, with permanent dipole moments existing at 5 nm<r<20 nm (14 mC/cm/sup 2/ at 20 nm), 10-90% reversible changes in the transmittance were observed while the Kerr rotation was apparently unaffected. This can be explained by a field-induced reversible agglomeration of about 5% of the particles. Irreversible agglomeration is also observed for high solid volume fractions and low stabilizer content.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"111 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124699337","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Liquid ionization detectors: the UA-1 collaboration 液体电离探测器:UA-1合作
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202872
A. Gonidec
{"title":"Liquid ionization detectors: the UA-1 collaboration","authors":"A. Gonidec","doi":"10.1109/ICDL.1990.202872","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202872","url":null,"abstract":"Summary form only given. Ionization chambers filled with liquefied noble gas have been commonly used as particle detectors. Recent research on warm liquids has made possible the construction of a large-scale calorimeter at CERN, filled with tetramethylpentane. For continuously sensitive detectors used in cosmic-ray physics, ultrahigh purity of the liquid is required to allow the electrons to travel over large distances without being trapped by impurities. Electron lifetimes of a few milliseconds have been reached in cryogenic liquids, and lifetimes of a few hundred microseconds have been obtained in warm liquids to assure good performance of the calorimeter.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"21 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125888077","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A new additive for improving the electrical property of liquid dielectric in power capacitor 一种改善电力电容器液体介质电性能的新添加剂
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202954
Z. Yu
{"title":"A new additive for improving the electrical property of liquid dielectric in power capacitor","authors":"Z. Yu","doi":"10.1109/ICDL.1990.202954","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202954","url":null,"abstract":"A new anti-ageing additive for improving the electrical properties and preventing the degradation of liquid dielectrics in power capacitors is introduced. When it is added in the right proportion, the partial discharge property of an all-film power capacitor impregnated by the liquid dielectric will be ameliorated and service life will be longer.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"140 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122413395","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The effect of residual conduction on weak unipolar injection and buoyancy driven instabilities 残余传导对弱单极注入和浮力驱动不稳定性的影响
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202908
F. Pontiga, A. Castellanos
{"title":"The effect of residual conduction on weak unipolar injection and buoyancy driven instabilities","authors":"F. Pontiga, A. Castellanos","doi":"10.1109/ICDL.1990.202908","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202908","url":null,"abstract":"The effect of residual conductivity on the stability of a horizontal dielectric liquid layer subjected to a weak unipolar injection and buoyancy is analyzed. Cases of heating from below and from above have been considered. Regions of steady and oscillatory instability are delineated by direct integration of the electrothermohydrodynamic equations for the case of constant mobility and permittivity.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126559361","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Electric field distribution in transformer oil containing an additive using the Kerr-effect technique under various DC stress conditions 用克尔效应技术研究了含添加剂变压器油在不同直流应力条件下的电场分布
10th International Conference on Conduction and Breakdown in Dielectric Liquids Pub Date : 1990-09-10 DOI: 10.1109/ICDL.1990.202947
H. Sato, Y. Nonaka, T. Takada
{"title":"Electric field distribution in transformer oil containing an additive using the Kerr-effect technique under various DC stress conditions","authors":"H. Sato, Y. Nonaka, T. Takada","doi":"10.1109/ICDL.1990.202947","DOIUrl":"https://doi.org/10.1109/ICDL.1990.202947","url":null,"abstract":"The electric field distribution profile in transformer insulating oil as a function of time after application of DC step voltage and change of the DC voltage polarity was measured using a highly sensitive advanced Kerr electrooptic technique. The lower limit of the applied electric field intensity was 100 V/cm in insulating oil with an electrode length of 8 cm. Charge distribution as a function of time was calculated from the measured electric field distribution. Mobilities of positive and negative ionic carriers, 0.025 and 0.030 cm/sup 2//Vs, respectively, were determined from the relationship between the saturation time of charge density and applied DC voltage. The relaxation time of accumulated charge near the electrodes after short-circuiting the electrodes was independent of the preapplied DC voltage.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126993817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信