Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting最新文献

筛选
英文 中文
High performance and long life uninterruptible power source using a flywheel energy storage unit 采用飞轮储能单元的高性能长寿命不间断电源
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152314
I. Takahashi, K. Amei, Y. Itoh
{"title":"High performance and long life uninterruptible power source using a flywheel energy storage unit","authors":"I. Takahashi, K. Amei, Y. Itoh","doi":"10.1109/IAS.1990.152314","DOIUrl":"https://doi.org/10.1109/IAS.1990.152314","url":null,"abstract":"The development of a flywheel uninterruptible power supply incorporating electrolytic capacitorless inverters and converters, optocouplerless power device drive circuits, loss reduction of high-frequency insulated-gate bipolar transistor (IGBT) inverters, and high-response regeneration control of the induction motor is described. Results from experiments performed on a three-phase, 5 kVA uninterruptible power source show that the system provides over 15 years of life, 100% input power factor, a 1% output voltage distortion, and a 93.4% efficiency.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132490799","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
The MPFB: a new type of field bus network for data collection and real-time process DCS MPFB:一种用于数据采集和实时处理DCS的新型现场总线网络
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152441
Wanxing Li
{"title":"The MPFB: a new type of field bus network for data collection and real-time process DCS","authors":"Wanxing Li","doi":"10.1109/IAS.1990.152441","DOIUrl":"https://doi.org/10.1109/IAS.1990.152441","url":null,"abstract":"The MPFB (multiple PC/processor field bus), a real time data collection and process DCS (distributed control system) field bus network that serves at a Bitbus, is discussed. A review of the history of field buses and computer integrated manufacturing systems is presented. The architecture, protocols, and characteristics of the MPFB are described. It is shown that, unlike the Bitbus, the MPFB provides a good distributed network environment for the real-time process DCSs, the field office automation systems, and the broadband integrated services.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130035594","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Noncontact sensing of physical parameters by Q measurement 通过Q测量实现物理参数的非接触传感
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152386
K. Namjoshi, P. Biringer
{"title":"Noncontact sensing of physical parameters by Q measurement","authors":"K. Namjoshi, P. Biringer","doi":"10.1109/IAS.1990.152386","DOIUrl":"https://doi.org/10.1109/IAS.1990.152386","url":null,"abstract":"Changes in the quality factor, Q, of a solenoid due to nearby nonmagnetic conducting objects are investigated. The influence of distance and supply frequency on the quality factor is calculated. The results are applied to estimate changes in parameters such as temperature and distance. The results show that changes in Q may be satisfactorily used to monitor physical properties of the workpiece, such as distance or temperature, without physical contacts.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"153 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116730804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Systematic design of a permanent magnet synchronous motor drive 永磁同步电机驱动系统的设计
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152212
P. Freere, P. Pillay
{"title":"Systematic design of a permanent magnet synchronous motor drive","authors":"P. Freere, P. Pillay","doi":"10.1109/IAS.1990.152212","DOIUrl":"https://doi.org/10.1109/IAS.1990.152212","url":null,"abstract":"Permanent magnet synchronous motors (PMSMs) operate at a high power factor, efficiency, and reliability. To achieve the performance of DC machines, the PMSM drive is vector controlled. Such a drive is described. The instantaneous position of the rotor is used to determine the required currents which the controller forces into the motor. The actual current is compared to the required or commanded current, and hysteresis or ramp comparison current controllers are used to force the actual current to follow the commanded. Detailed circuits and experimental results are provided. Operation in the flux weakening region is also shown.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114473178","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Control of force-commutated direct frequency changers 力换相直接变频器的控制
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152331
Y.H. Kim, M. Ehsani
{"title":"Control of force-commutated direct frequency changers","authors":"Y.H. Kim, M. Ehsani","doi":"10.1109/IAS.1990.152331","DOIUrl":"https://doi.org/10.1109/IAS.1990.152331","url":null,"abstract":"The three-stage operation of force-commutated, direct-type frequency changers, which provides the capabilities of output magnitude control, harmonic control, and input power factor control, especially when microprocessor-based control is used, is described. The harmonic analysis of a three-phase input, three-phase output system and the implementation of the three-stage operation are presented. The implementation results are discussed.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114987549","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Array-code identification tags 数组代码识别标签
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152385
W. Little, P. Baker, L. Kirlin, B. Sauder
{"title":"Array-code identification tags","authors":"W. Little, P. Baker, L. Kirlin, B. Sauder","doi":"10.1109/IAS.1990.152385","DOIUrl":"https://doi.org/10.1109/IAS.1990.152385","url":null,"abstract":"Array-code identification tags are generalized 2D bar codes that can be read from a large distance with an image processing system. The array-code identification tags, a prototype array-code system, and typical array-code applications are described. The algorithms and performance of the prototype system are outlined, and generic features of the technology are discussed.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133738288","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Power factor improvement for high power low voltage AC arcs 大功率低压交流电弧的功率因数改进
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152315
F. Dawson
{"title":"Power factor improvement for high power low voltage AC arcs","authors":"F. Dawson","doi":"10.1109/IAS.1990.152315","DOIUrl":"https://doi.org/10.1109/IAS.1990.152315","url":null,"abstract":"The operation of two series-connected static voltampere reactive (VAR) compensators suitable for 3 phi AC arc loads is described. The circuit model for an arc furnace and factors contributing to the determination of the equivalent circuit parameters are discussed. Two types of active compensators, shunt compensators and a cycloconverter are discussed briefly. The operating principles for a single phase of the current-source-fed and voltage-source-fed converter, three-phase power circuit representations, and the analysis for a single phase of a current and voltage-driven series converter, including graphical results, are presented.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133779271","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Voltage distortion of rotary UPS and standby engine generator sets 旋转UPS和备用发动机发电机组的电压畸变
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152423
A. Kusko, S. Peeran
{"title":"Voltage distortion of rotary UPS and standby engine generator sets","authors":"A. Kusko, S. Peeran","doi":"10.1109/IAS.1990.152423","DOIUrl":"https://doi.org/10.1109/IAS.1990.152423","url":null,"abstract":"Methods for calculating the voltage distortion produced by nonlinear loads, and design concepts for reducing the distortion are described. The impact of reducing saliency in the rotor construction and in the damper windings on the impedance of the generator to harmonic currents is analyzed. It is shown that generator voltage distortion under nonlinear loads can be controlled by either one of two methods, overrating the generator to make the nonlinear load a smaller percentage of the generator rating, or reducing the internal impedance of the generator to the harmonics of the nonlinear load current.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133475288","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Starting performance of delta-modulated inverter-fed submersible motors 三角调制变频调速潜水电机的起动性能
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152167
M. Rahman, M. A. Choudhury
{"title":"Starting performance of delta-modulated inverter-fed submersible motors","authors":"M. Rahman, M. A. Choudhury","doi":"10.1109/IAS.1990.152167","DOIUrl":"https://doi.org/10.1109/IAS.1990.152167","url":null,"abstract":"An analysis of the starting performance of tuned delta-modulated inverter-fed submersible motors is presented. Submersible motors are induction motors that have unique constructional features. These motors are required to operate in one of the most harsh environmental conditions. The operating characteristics of a submersible motor pump system require soft starting facility and variable-speed operation. To satisfy both requirements, a delta-modulated inverter supply is proposed, and the system starting performance is presented. The soft starting characteristic of the motor is obtained by the inherent V/F control of the delta-modulated inverter. The analysis is carried out using time domain representation of inverter voltages and the d-q axis model of the motor. The time-domain representation of inverter voltages is done using gate functions. The starting performances of submersible motors improved substantially. Though the analysis and results presented in this paper are for a submersible motor, they are equally applicable for any type of polyphase induction motor.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132434962","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Performance assessment of lightning shielding systems 雷电屏蔽系统性能评估
Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting Pub Date : 1990-10-07 DOI: 10.1109/IAS.1990.152459
A. Liew, C.M. Gui
{"title":"Performance assessment of lightning shielding systems","authors":"A. Liew, C.M. Gui","doi":"10.1109/IAS.1990.152459","DOIUrl":"https://doi.org/10.1109/IAS.1990.152459","url":null,"abstract":"PALSS (performance assessment of lightning shielding systems), a computer program for the evaluation of the performance of overhead lightning shielding systems, is discussed. The program is written in C-language and is enhanced with illustrative graphics. The analytical method used by the program is based on a three-dimensional implementation of the electrogeometric model of the lightning stroke, shielding system configuration, and structures that are to be protected. A Monte Carlo technique is used to manipulate the statistical distributions of the lightning stroke parameters to yield a quantitative assessment. Examples of the use of PALSS in studies on a substation and a commercial building complex are presented.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123498401","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信