{"title":"Representation of Grid Forming Virtual Oscillator Controller Dynamics with WECC Generic Models","authors":"D. Ramasubramanian, E. Farantatos","doi":"10.1109/PESGM46819.2021.9638062","DOIUrl":"https://doi.org/10.1109/PESGM46819.2021.9638062","url":null,"abstract":"The global proliferation of inverter based resources (IBRs) has brought to light interesting challenges that may be faced in operation of the bulk power system. Recent research has resulted in the emergence of so called grid forming inverter control architectures. There is however a concern that while power system planners might need IBRs to have grid forming capabilities, a lack of availability of generic models may become a huge obstacle in carrying out adequate large system simulation studies. In this paper, the ability of the existing WECC generic models to represent the behavior of a virtual oscillator based grid forming IBR will be showcased. The dynamic analysis is compared both in electromagnetic domain and positive sequence domain.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123119649","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigating increased renewable energy penetration on San Cristobal Island in the Galapagos archipelago","authors":"Nicole Fronsdahl, Pritpal Singh","doi":"10.1109/pesgm46819.2021.9637838","DOIUrl":"https://doi.org/10.1109/pesgm46819.2021.9637838","url":null,"abstract":"This study evaluates the current power system on San Cristobal Island in the Galapagos archipelago and studies the feasibility of integrating renewable energy into the power grid. With a small population and lack of power-intensive industries, San Cristobal has a low electricity demand. That being said, over 90% of the land and ocean area are protected as conservation land which limits the available space for new energy infrastructure development. The combination of solar, energy storage, and demand management techniques will play a large role in reducing fossil fuel consumption. This study provides generation mix predictions for expected demand in 2019, 2022, and 2025. The model predicts that solar installations in combination with energy storage can supply enough energy to support the demand on the island.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"204 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116627433","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Online Scheduling of a Residential Microgrid via Monte-Carlo Tree Search and a Learned Model","authors":"H. Shuai, Haibo He","doi":"10.1109/PESGM46819.2021.9637996","DOIUrl":"https://doi.org/10.1109/PESGM46819.2021.9637996","url":null,"abstract":"The uncertainty of distributed renewable energy brings significant challenges to economic operation of microgrids. Conventional online optimization approaches require a forecast model. However, accurately forecasting the renewable power generations is still a tough task. To achieve online scheduling of a residential microgrid (RM) that does not need a forecast model to predict the future PV/wind and load power sequences, this paper investigates the usage of reinforcement learning (RL) approach to tackle this challenge. Specifically, based on the recent development of Model-Based Reinforcement Learning, MuZero [1], we investigate its application to the RM scheduling problem. To accommodate the characteristics of the RM scheduling application, a optimization framework that combines the model-based RL agent with the mathematical optimization technique is designed, and long short-term memory (LSTM) units are adopted to extract features from the past renewable generation and load sequences. At each time step, the optimal decision is obtained by conducting Monte-Carlo tree search (MCTS) with a learned model and solving an optimal power flow sub-problem. In this way, this approach can sequentially make operational decisions online without relying on a forecast model. The numerical simulation results demonstrate the effectiveness of the proposed algorithm.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116717218","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fault Transient Analysis of Multi-IIG Power System at System Level","authors":"Bin Yang, K. Jia, T. Bi","doi":"10.1109/PESGM46819.2021.9638144","DOIUrl":"https://doi.org/10.1109/PESGM46819.2021.9638144","url":null,"abstract":"Fault transient analysis is the research basis for full time domain based protection, which is required by the future power system with high proportion of inverter interfaced generator (IIG) access. This paper proposes a solvable analysis method for fault transient at system level. By dynamic phase conversion of IIG output and modification on system equation for transient analysis, the relationship between transient currents and nodal voltages can keep linear. As a result, fault transient of the whole multi-IIG system can be deduced without high order calculation. The correctness and effectiveness of the proposed method are verified in the multi-IIG simulation system.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127434338","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"AC Power Flow Convergence in CAISO Outage Analysis with Short-Term Load Forecast","authors":"Mengjia Xiao, A. Alam, Jiankang Wang","doi":"10.1109/PESGM46819.2021.9638006","DOIUrl":"https://doi.org/10.1109/PESGM46819.2021.9638006","url":null,"abstract":"In recent years, the large amount of renewable energy resources integrated into the power system has sparked significant challenges in power grid outage studies. Traditional outage studies which only consider peak load scenarios with static unit schedules lead to over-conservative results. The methodology is also lacking consideration of variance of renewable energy dispatches and energy market constraints. As RC West officially became Reliability Coordinator (RC) for 42 power utilities in the western interconnection, California Independent System Operator (CAISO) adopted a framework called Integrated Optimal Outage Coordination (IOOC) in collaboration with Siemens to effectively and automatically generate power flow cases for outage analysis using short-term load forecast. However, the AC power flow non-convergence issue appears occasionally in IOOC. This paper analyzes and summarizes four root causes for the non-convergence issue: erroneous load distribution and load power factors, deviating interchange requirements, improper voltage regulation settings, and incorrect default breaker/switch positions. Furthermore, this paper proposes practical solutions for each root cause to improve AC power flow convergence in IOOC.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114433337","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Abhyankar, S. Peles, R. Rutherford, Asher Mancinelli
{"title":"Evaluation of AC optimal power flow on graphical processing units","authors":"S. Abhyankar, S. Peles, R. Rutherford, Asher Mancinelli","doi":"10.1109/PESGM46819.2021.9638131","DOIUrl":"https://doi.org/10.1109/PESGM46819.2021.9638131","url":null,"abstract":"This paper investigates the performance of alternating current optimal power flow (ACOPF) on hardware accelerators such as graphical processing units (GPUs). We describe the strategies employed and the software used to port the ACOPF application to GPU. Through reorganizing the flow of fundamental calculations, restructuring data organization for the GPUs, and using portability libraries, maximum utilization of GPU is attempted. We present details of our efforts with representative results on 200, 500, and 2000-bus networks.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121988770","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations","authors":"K. Hatipoglu, M. Olama","doi":"10.1109/PESGM46819.2021.9638141","DOIUrl":"https://doi.org/10.1109/PESGM46819.2021.9638141","url":null,"abstract":"This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"328 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122131042","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Flexible Form Factor Digital Optical Current Sensor With Triple Redundancy","authors":"F. Ferdous, Manicka K. Pari, A. Rose","doi":"10.1109/pesgm46819.2021.9637868","DOIUrl":"https://doi.org/10.1109/pesgm46819.2021.9637868","url":null,"abstract":"In this paper, a new current sensor with 3 sensors in a single sensing head cable is presented. The sensors perform to the IEC 0.2 accuracy class over the -40°C to +50°C temperature range for metering and protection applications. These new sensors in the same sensing cable provide redundancy for lower installation costs and less space needed for the sensors. The output of the sensors can be from DC to 20 kHz. The primary output of the sensor is in a digital format, IEC 61850-9-2LE, suitable for Smart-Grid applications in a digital substation.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117291183","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sequence Impedance Modeling of Grid-Forming Inverters","authors":"Weihang Yan, Shahil Shah, V. Gevorgian, D. Gao","doi":"10.1109/PESGM46819.2021.9638001","DOIUrl":"https://doi.org/10.1109/PESGM46819.2021.9638001","url":null,"abstract":"Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129304954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hao Li, Zongxiang Lu, Ying Qiao, Baosen Zhang, Yisha Lin
{"title":"The Flexibility Test System for Studies of Variable Renewable Energy Resources","authors":"Hao Li, Zongxiang Lu, Ying Qiao, Baosen Zhang, Yisha Lin","doi":"10.1109/pesgm46819.2021.9637825","DOIUrl":"https://doi.org/10.1109/pesgm46819.2021.9637825","url":null,"abstract":"The flexibility of power systems to manage vari-ability and uncertainties is becoming increasingly important as the penetration of variable renewable energy continues to raise. Synergies from all parts of the existing system and new flexibility providers are required to balance demand and supply. However, because of fundamental limitations, existing test systems cannot fully support detailed and realistic studies. To fill this gap, this paper presents a 213-bus benchmark, called the FTS-213 system, dedicated for power system flexibility studies. This system has more than 38% of VRE penetration and includes real data at 15 minutes and 1 minute resolutions. The resources considered in the system cover all aspects of the generation, network, demand, energy storage and market. Specifically, to capture the intrinsic relationship between flexibility and renewable energy accommodation, the system contains integration grids, regional transmission grids and inter-regional tie lines. These assets reflect the full stack of utility-scale integration, transmission and consumption within and among regions. They cover multiple voltage levels, from 110 to 750 kV AC and ±400 to ±800 kV DC. The impacts of and the interactions between these flexibility factors are analyzed and three sets of planning results are provided.","PeriodicalId":184061,"journal":{"name":"2021 IEEE Power & Energy Society General Meeting (PESGM)","volume":"309 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129354623","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}