T. Seyler, M. Fratz, A. Schiller, A. Bertz, D. Carl, T. Schmitt-Manderbach, Markus Langer
{"title":"Digital holography in a machine tool: measuring large-scale objects with micron accuracy","authors":"T. Seyler, M. Fratz, A. Schiller, A. Bertz, D. Carl, T. Schmitt-Manderbach, Markus Langer","doi":"10.1117/12.2673585","DOIUrl":"https://doi.org/10.1117/12.2673585","url":null,"abstract":"We present digital multi-wavelength holography measurements generated inside a machine tool. The digital holographic sensor HoloTop NX used in the application has a field of view of 12.5 mm × 12.5 mm, each field of view consists of 3008 px × 3008 px. Three separately stabilized diode lasers connected to a fiber switch serve as light sources. The unambiguous measurement range of the holographic sensor defined by the laser wavelengths is approximately 140 μm and the axial reproducibility is ~0.4 μm. The sensor is mounted to a standard 5-axis machine tool Hermle C 32U. An automatically created numerical control (NC) program enables the machine tool to meander the sensor over larger test objects, here 280 mm × 94 mm. For each field of view, a height map with 9 million data points is generated using digital holography. The images are acquired with 2 mm lateral overlap and are then stitched together to achieve a height map of the complete sample with more than 1.4 billion data points. For comparison the shape of the sample was measured with a state-of-the-art coordinate measurement machine (CMM). The datasets from the CMM and the holographic measurement are semi-automatically referenced to each other. The holographic height data are averaged over a rectangular area with radius 50 μm around each of the 360 measurement locations where the tactile CMM measurement data have been acquired. This allows us to evaluate deviations between the holographic and the CMM dataset. It turns out that the root mean square (RMS) error between the two data sets is smaller than 0.4 μm.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121080897","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation to evaluate the aging condition utilizing UV radiation of carbon black filled rubber compounds as measured by ATR spectroscopy","authors":"Florian Rudek, Linda Weichenhain, P. Hartmann","doi":"10.1117/12.2673848","DOIUrl":"https://doi.org/10.1117/12.2673848","url":null,"abstract":"Rubber, particularly carbon black-filled rubber used in tires, plays a critical role in a world of mobility. Tires are exposed to various influences, including temperature fluctuations, dynamic mechanical loads, and exposure to solar-origin UV radiation, which can affect their durability. To investigate the effects of UV radiation on tire aging, this study aimed to identify spectral absorption ranges in specifically aged tire samples providing information about their aging condition. The study utilized samples of different rubber compounds and exposed them to UV radiation for varying durations from 48 h up to 1000 h. ATR (attenuated total reflection) spectroscopy was used to analyze the aged samples and evaluate changes in their chemical structure. The results showed consistent aging behavior across all samples, with a decrease in the intensity of the double peak at approximately 2900 cm-1, corresponding to the C-H bond. Another aging-relevant range from 1500 cm-1 to 1450 cm-1, characteristic of C-H groups as well, exhibited a declining absorption trend with UV aging. The impacts on the absorption spectrum resulting from the different rubber mixtures' compositions led to a reduction in the intensity of characteristic peaks. For evaluating the aging state of used tires, the CH related peaks can be utilized.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125876255","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The use of deep learning for computational optical imaging: from data driven to physics driven","authors":"G. Situ","doi":"10.1117/12.2681500","DOIUrl":"https://doi.org/10.1117/12.2681500","url":null,"abstract":"Recently deep neural networks (DNN) has shown the great capability of solving various inverse problems in computational optical imaging. Conventionally, DNN should be trained by a large set of paired or unpaired data. The most critical issue with this paradigm is that the neural network inference has no physical interpretation or limited generalization. In order to resolve these issues, one solution is to incorporate the physics of the problems in hand into the training of DNN, resulting in a novel framework that is called physics-enhanced deep neural networks or, PhysenNet, for short. Here we present a brief review of recent works in this regard with the use cases of phase imaging and ghost imaging. We will show that PhysenNet does not need any data to train. Instead, it learns from the physics of the given problem. Therefore the output of PhysenNet is naturally satisfied with the constrain imposed by the corresponding physical model. We would also like to emphasize that the concept of PhysenNet is quite generic, and can be used to solve many other inverse problems even outside the scope of imaging.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123593467","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Panpan Xia, T. Grabe, T. Biermann, A. Ziebehl, Simon Teves, R. Lachmayer
{"title":"Tolerance analysis and design optimization of additively manufactured mechanical structure for a Raman spectrometer system","authors":"Panpan Xia, T. Grabe, T. Biermann, A. Ziebehl, Simon Teves, R. Lachmayer","doi":"10.1117/12.2673436","DOIUrl":"https://doi.org/10.1117/12.2673436","url":null,"abstract":"Additive Manufacturing (AM) to produce parts of optical systems is gaining popularity due to design flexibility and functional integration. However, one of the significant challenges in the field of AM for optical systems is the limited manufacturing accuracy compared to traditional manufacturing methods. This causes an increase in manufacturing and assembly errors, which affects the fit and function of the produced parts and therefore the performance of the optical system. This work aims to reduce the negative impact of manufacturing and assembly errors on optical performance, as exemplified in practice by additively manufacturing housings and lens mounts for a Raman spectroscopy system. For this, the simulated optical system of a Raman spectrometer is used to perform the optical tolerance analysis, such as identifying critical components and sensitivity analysis. The Manufacturability of additive manufacturing is then evaluated by measuring printed standard specimens. According to optical and mechanical tolerance analysis, design and manufacturing problems can be found. Then the structure is optimized using the design flexibility provided by additive manufacturing, and accumulated errors from assembly and manufacturing are reduced by minimizing the number of installed components. Measuring the intensity of the Raman signal revealed that the improved design reduced the accumulated errors in the mechanical structure. In addition, the signal-to-noise ratio is significantly enhanced by 265 % compared to the non-optimized design. Hence, this design optimization based on tolerance analysis is an effective methodology for enhancing the performance of additively manufactured optical systems from the perspective of AM technology development in optical domain.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"13 6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127018800","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Manashee Adhikary, T. Cromwijk, S. Witte, J. D. de Boer, A. D. den Boef
{"title":"Robust semiconductor overlay metrology with non-uniform illumination beams using digital holographic microscopy","authors":"Manashee Adhikary, T. Cromwijk, S. Witte, J. D. de Boer, A. D. den Boef","doi":"10.1117/12.2673583","DOIUrl":"https://doi.org/10.1117/12.2673583","url":null,"abstract":"Precise, accurate, and fast characterization of overlay between two layers of semiconductors during chip fabrication is an important monitoring and feedback step. Overlay, which is to be measured within the accuracy of a nanometer, is susceptible to many small imperfections in the measurement system. A digital holographic microscope measures the complex field of overlay targets using simple optics followed by computational algorithms for overlay metrology. We improved the precision of overlay measurement by correcting the inhomogeneities and asymmetries caused by the illumination spots, presenting a robust method resulting from simple calibration steps.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"137 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123681001","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Microsphere-assisted microscopy: challenges and opportunities","authors":"A. Darafsheh, Vahid Abbasian","doi":"10.1117/12.2681499","DOIUrl":"https://doi.org/10.1117/12.2681499","url":null,"abstract":"Optical microscopy is one the oldest and most widely used techniques for sample inspection in life and material sciences. Microsphere-assisted microscopy (MAM) has emerged as a simple yet efficient approach to boost the spatial resolution. MAM uses a microsphere, placed in the immediate vicinity of the object, to enhance the numerical aperture and improve the resolution. MAM can be used in conjunction with white-light, wide-field, bright-field, dark-field, confocal, fluorescent, second harmonic generation, two-photon, interferometric, and digital holographic microscopies. It can be employed in reflection and transmission modes. There are several open questions and challenges associated with MAM, including the resolution limit, the mechanism behind resolution improvement, and the limited imaging field-of-view. Here, we present the progress in MAM in the past decade along with the associated opportunities and challenges.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"106 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134582625","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Accelerated measurement and defect characterization on large optical components","authors":"Matthias Liedmann, T. Machleidt","doi":"10.1117/12.2673089","DOIUrl":"https://doi.org/10.1117/12.2673089","url":null,"abstract":"Measurement and characterization of small defects on large areas are time consuming but can be accelerated using high speed cameras and GPGPUs (general purpose graphic processing units). A height map of a filter glass with a 50 mm diameter scanned with a spatial sampling of 1 μm must present the data of more than 1000 single scans or 2.5 billion measuring points on a screen. Stitching processes of such data amount exceed the capacity of actual available metrology software packages even while operating on high end PCs. Resampling processes may result in a loss of information about surface roughness and small defects. Batch processing of the single scans is possible but make the interpretation of measuring results complicate and time consuming. Task specific data processing strategies overcome the given limitations. Disturbing residual stitching errors in overlapping zones are avoided and small scratches can still be observed in 3d maps of the complete sample. This simplifies the localization and provide information for preventive measures. Similar but adapted processing strategies are available to visualize local fluctuations of the surface textures. Test was done using the optical profiler smartWLI firebolt. The sensor operates on the measuring principal CSI - coherence scanning (white-light) interferometry and uses a 1.3 MP camera with 935 fps / full resolution. Data are processed in real time using a CUDA programmable NVIDIA graphic board which provides a calculation power of up to 82.6 FP32-TFLOPs. Thus, resulting in acquisition performance of up to approximately 1 single scan per second.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132799251","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Adam Semancík, Jakub Hynek, Samuel Lukacovic, T. Koutecký
{"title":"Photogrammetry for optical metrology of parts manufactured by additive manufacturing","authors":"Adam Semancík, Jakub Hynek, Samuel Lukacovic, T. Koutecký","doi":"10.1117/12.2673700","DOIUrl":"https://doi.org/10.1117/12.2673700","url":null,"abstract":"The aim of this paper was to test the suitability of using photogrammetry for metal additively manufactured parts with respect to metrology applications. Another aim was to test the influence of the chosen parameters on the quality indicators of the measurement data and the suitability of using single and stereo camera setups. The parameters of the measurement system whose influence was assessed were the exposure time, number and resolution of images taken. The individual measurements were evaluated in terms of the computational complexity, number of points obtained, part coverage ratio and the standard deviation of the distances of all points from the surface of the reference model. By comparing the results, a matrix of optimal parameters for the given part types was created and further trends describing the influence of individual parameters on the results were observed. The experimental comparison performed shows the possibilities of photogrammetric measurements, gives an idea of the appropriate parameters settings and has also shown that photogrammetry can be a competitor to fringe projection scanning of metal additively manufactured parts. The main drawback of this method is still the computational time and the need for a distinctive surface texture.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128840014","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
B. Hauer, Adrian Daniel Dorfschmidt, F. Münch, Jens Scherer, D. Carl
{"title":"An infrared optical sensor for quantitative inline inspection of nanocoatings on plastic products","authors":"B. Hauer, Adrian Daniel Dorfschmidt, F. Münch, Jens Scherer, D. Carl","doi":"10.1117/12.2673229","DOIUrl":"https://doi.org/10.1117/12.2673229","url":null,"abstract":"We developed a fast infrared sensor to quantify the film thickness of industrially applied SiOx or AlOx plasma coatings on non-flat polymer substrates at production speed. Its underlying physical principle is comparable to infrared reflection absorption spectroscopy (IRRAS) at selected, fixed wavelengths. The coating materials can be measured via their specific phononic absorption bands in the infrared spectral range. In this paper, we demonstrate the functionality of our sensor on actual packaging materials to showcase its aptitude for industrial inline inspection. Furthermore, we discuss a possible extension of our sensor to enable spectroscopic measurements using a tunable Fabry-Pérot filter.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128474268","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Towards image-free object detection for autonomous vehicles under harsh environmental conditions","authors":"C. Bett, K. Frenner, S. Reichelt, W. Osten","doi":"10.1117/12.2675716","DOIUrl":"https://doi.org/10.1117/12.2675716","url":null,"abstract":"There exist two key aspects to enable autonomous vehicles: Robust sensors to provide all relevant data concerning the vehicle's surroundings as well as algorithms to evaluate this data in real time. Apart from radar and ultrasonic sensors, optical sensors such as lidar and cameras are state-of-the-art in prototype autonomous vehicles. In adverse weather conditions, such as e.g. fog, snow, dust, heavy rain or poorly illuminated scenes, though, those sensors do not perform reliably. Recently, we proposed to use a time-gated-single-pixel-camera to not only significantly reduce the amount of recorded data but additionally filter ballistic object photons, i.e. suppress the effect of noise from the obscuring medium. Apart from generating 3D object information, such a system can operate fast enough to deal with the highly dynamic environment as well as respect eye-safety norms. Moreover, a time-gated-single-pixel-camera offers the ability of image-free detection of all relevant objects within the scene which speeds up data evaluation as well. Here, we want to report on our progress towards realizing such a system. We will demonstrate image-free object detection on simulated data. We realize multi-object detection by generating object heat-maps for the different classes. Additionally, we discuss the difficulties we have to overcome to robustly detect objects in real measured data and shortly present our prototype setup, which we have implemented on a car together with our partners from Fraunhofer Institut für Physikalische Messtechnik and Institut für Autonome Intelligente Systeme, Universität Freiburg.","PeriodicalId":183246,"journal":{"name":"Optical Metrology","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128678264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}