2017 IEEE Second International Conference on DC Microgrids (ICDCM)最新文献

筛选
英文 中文
Co-location of CHP units for High Power Charging of Battery Electric Vehicles: A comparison of the fuel efficiency for AC and DC coupled systems 纯电动汽车大功率充电热电联产机组的协同配置:交直流耦合系统燃油效率的比较
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-08-08 DOI: 10.1109/ICDCM.2017.8001027
Kyle Smith, S. Galloway, G. Burt
{"title":"Co-location of CHP units for High Power Charging of Battery Electric Vehicles: A comparison of the fuel efficiency for AC and DC coupled systems","authors":"Kyle Smith, S. Galloway, G. Burt","doi":"10.1109/ICDCM.2017.8001027","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001027","url":null,"abstract":"This paper proposes the co-location of gas reciprocating generator sets with High Power Charging (HPC) stations for Battery Electric Vehicles (BEVs), to offer a low carbon source of heat and power which could help to meet national government transportation and heating strategies while minimizing the impact that HPC systems will have on the power network. Three different Combined Heat and Power (CHP) connection configurations are considered to determine the most fuel-efficient per forecasted utilization rates of the HPC station. The use of variable speed generators connected directly to the dc bus of the HPC station can offer improved fuel-efficiency performance compared to fixed speed, especially under part-loading conditions, however, the sizing of engine-generator sets based on expected utilization rates of the HPC station has the most influence on fuel efficiency.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133264179","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Practical computation of di/dt for high-speed protection of DC microgrids 直流微电网高速保护di/dt的实用计算
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-08-07 DOI: 10.1109/ICDCM.2017.8001037
Chunpeng Li, P. Rakhra, P. Norman, P. Niewczas, G. Burt, P. Clarkson
{"title":"Practical computation of di/dt for high-speed protection of DC microgrids","authors":"Chunpeng Li, P. Rakhra, P. Norman, P. Niewczas, G. Burt, P. Clarkson","doi":"10.1109/ICDCM.2017.8001037","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001037","url":null,"abstract":"DC microgrids have the potential to radically disrupt the distribution system market due to the benefits offered in easing the integration and control of distributed renewable energy resources and energy storage systems. However, the non-zero-crossing fault current profiles associated with short-circuited DC systems present a major challenge for protection. Isolation of faulted networks prior to the peak-current discharge of DC-side capacitors may address this challenge if rapid fault detection speeds (shorter than 2ms) can be achieved. Accordingly, novel methods of utilising the rate-of-change-of-current (di/dt) have been proposed in the literature to realize new, high-speed distance protection strategies. This paper proposes two practical methods for optimizing the numerical computation of di/dt of fault current transients and evaluates the performance of each within a MATLAB/Simulink model of a DC microgrid with artificially injected measurement noise.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122749034","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
Energy management strategy for renewable backup supply 可再生备用电源的能源管理策略
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-08-03 DOI: 10.1109/ICDCM.2017.8001105
Chung-Lun Li, Chih-Han Lin, Le-Ren Chang-Chien
{"title":"Energy management strategy for renewable backup supply","authors":"Chung-Lun Li, Chih-Han Lin, Le-Ren Chang-Chien","doi":"10.1109/ICDCM.2017.8001105","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001105","url":null,"abstract":"This paper proposes an energy management strategy for backup supply system which efficiently coordinates power flow among renewable energy resources within the DC microgrid. To ensure reliable power at the supply side, the fuel cell is employed to work as a base-load supply and the lead-acid battery storage is used to buffer the power imbalance between renewable generation and load demand. The fuel cell system is interfaced with a 450W current-fed full-bridge isolated DC-DC converter for controlling the output power of the fuel cell. The lead-acid battery bank is interfaced with a 1.5kW dual-active-bridge bidirectional DC-DC converter for buffering the power difference among renewable energy resources and loads. The hybrid renewable energy converters are coordinated by CAN-Bus communication. Experimental tests are conducted to validate the function of the energy management control and strategy.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131385363","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Active DC bus signaling control method for coordinating multiple energy storage devices in DC microgrid 用于协调直流微电网中多个储能设备的直流母线主动信令控制方法
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-08-03 DOI: 10.1109/ICDCM.2017.8001048
Fulong Li, Zhengyu Lin, Z. Qian, Jiande Wu
{"title":"Active DC bus signaling control method for coordinating multiple energy storage devices in DC microgrid","authors":"Fulong Li, Zhengyu Lin, Z. Qian, Jiande Wu","doi":"10.1109/ICDCM.2017.8001048","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001048","url":null,"abstract":"Management of multiple energy storage devices in a DC microgrid is a challenge. Conventional method, such as droop control, cannot ensure accurate current sharing in coordinating multiple battery banks, which limits the DC microgrid system performance. This paper proposed an active DC bus signaling (ADBS) method to coordinate multiple battery banks in a DC microgrid. It has the advantages of accurate current sharing. Using the proposed ADBS method, the master controller can collect State of charge (SoC) of each slave battery bank by actively varying the DC bus voltage levels and monitoring the current change. The master module then sets a working voltage level after decision-making. The proposed method was experimentally evaluated, and the experimental results show that all the possible working voltage levels can be reached and the accuracy of current sharing is guaranteed.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124374930","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 30
A novel protection scheme for an LVDC distribution network with reduced fault levels 一种新型低故障级LVDC配电网保护方案
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-06-29 DOI: 10.1109/ICDCM.2017.8001024
Dong Wang, A. Emhemed, G. Burt
{"title":"A novel protection scheme for an LVDC distribution network with reduced fault levels","authors":"Dong Wang, A. Emhemed, G. Burt","doi":"10.1109/ICDCM.2017.8001024","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001024","url":null,"abstract":"Low Voltage Direct Current (LVDC) distribution is one of the new promising technologies that have the potential to accelerate the wider integration of distributed renewables. However, adding new power electronics to convert AC to DC will introduce new forms of faults with different characteristics. Converters with inherent fault current limiting and blocking capabilities will significantly limit the fault currents, resulting in significant impacts on the performance of existing LV overcurrent protection schemes. New protection methods based on the change in the DC voltages have been proposed recently by different researches. The issue with these methods is that the protection relays of the un-faulted feeders will also see the same change in the voltage for certain faults, leading to substandard selectivity and unnecessary tripping. This paper investigates these challenges, and presents a novel DC protection method which is based on the use of the combination of two components: the voltage change (dv/dt) and the change of current (di/dt). The new method is mainly developed to detect and locate DC faults with reduced fault current levels within DC distribution networks. The introduced protection concept is tested on an LVDC distribution network example using PSCAD/EMTDC simulation tool.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128727417","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Resonant electric arcs in DC microgrids with low system impedance in the VLF-band 低频带低系统阻抗直流微电网的谐振电弧
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-06-27 DOI: 10.1109/ICDCM.2017.8001014
C. Strobl, L. Ott, Julian Kaiser, M. Streck, Frank Nothnagel, F. Berger, Maximilian Schäfer, R. Rabenstein
{"title":"Resonant electric arcs in DC microgrids with low system impedance in the VLF-band","authors":"C. Strobl, L. Ott, Julian Kaiser, M. Streck, Frank Nothnagel, F. Berger, Maximilian Schäfer, R. Rabenstein","doi":"10.1109/ICDCM.2017.8001014","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001014","url":null,"abstract":"Various fault scenarios have been analyzed by running a number of differently combined 380 VDC microgrid tests. These tests represented a common grid topology with low system impedance at grid resonance points within the single- or lower double-digit kHz range. At serial arc faults, self-excited resonant modes of the arc plasma column have been observed. They lead to an increased arc column stability compared to non-resonant arcs with colored noise behavior. These characteristics require a special focus on pattern recognition methods for arc fault sensors along with extended suitability tests for mechanical and hybrid switchgear concerning the altered stability of switching arcs. The use of small-signal models for system components such as source and load converters as well as for arcs with regard to large-signal DC operating points and converter control modes is helpful in order to describe the reaction of the system in the event of a malfunction. This is essential for the development of suitable protective components and algorithms.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115079715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
DC power distribution: New opportunities and challenges 直流配电:新的机遇和挑战
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-06-27 DOI: 10.1109/ICDCM.2017.8001020
L. Qi, Jiuping Pan, L. Liljestrand, M. Backman, A. Antoniazzi, L. Raciti, M. Riva
{"title":"DC power distribution: New opportunities and challenges","authors":"L. Qi, Jiuping Pan, L. Liljestrand, M. Backman, A. Antoniazzi, L. Raciti, M. Riva","doi":"10.1109/ICDCM.2017.8001020","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001020","url":null,"abstract":"The benefits offered by the DC energy distribution in different applications raised the interests towards new power architectures and apparatus. The availability of the related LV and MV apparatus and protection schemes is in fact crucial to fully exploit the opportunities opened in the energy management for the smart grid. Experimental results of testing DC circuit breakers based upon current injection and solid-state technologies are presented and their effectiveness for DC distribution protection is discussed. The possibilities opened by local measurement and communication to support the operation of DC circuit breakers for DC protection as well as the design challenges and implementation issues are investigated.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115571030","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Electricity market design requirements for DC distribution systems 电力市场对直流配电系统的设计要求
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-06-27 DOI: 10.1109/ICDCM.2017.8001028
Longjian Piao, M. D. de Weerdt, L. D. de Vries
{"title":"Electricity market design requirements for DC distribution systems","authors":"Longjian Piao, M. D. de Weerdt, L. D. de Vries","doi":"10.1109/ICDCM.2017.8001028","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001028","url":null,"abstract":"DC distribution systems (DCDS) connect local generators and loads directly. By avoiding unnecessary losses in AC-DC conversion, DCDS offers higher energy efficiency. Since different parties in a DCDS may have conflicting goals, matching between power supply and demand should be done with carefully designed allocation rules and monetary transfers, such that no one prefers to act otherwise than the outcome of the allocation. This paper reveals DCDS' unique operational requirements and indicates the challenges and opportunities they pose to market design. A design framework is introduced into DCDS electricity market, incl. tradable services, design goals, market participants, design options and performance criteria. We review the existing market models for AC and DC distribution systems and point out the direction for future work.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114316464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
PSCAD/EMTDC-based simulations for fault analysis and fault identification in 380V ring DC systems 基于PSCAD/ emtdc的380V环形直流系统故障分析与故障识别仿真
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-06-27 DOI: 10.1109/ICDCM.2017.8001036
Julia Niewind, N. Hemdan, Christoph Klosinski, M. Kurrat, F. Gerdinand, J. Meisner, S. Passon
{"title":"PSCAD/EMTDC-based simulations for fault analysis and fault identification in 380V ring DC systems","authors":"Julia Niewind, N. Hemdan, Christoph Klosinski, M. Kurrat, F. Gerdinand, J. Meisner, S. Passon","doi":"10.1109/ICDCM.2017.8001036","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001036","url":null,"abstract":"With an increasing number of DC driven components in power networks, the introduction of 380V DC distribution grids appears to be a valuable option. Besides all positive aspects of DC systems (e.g. high efficiency, the absence of reactive power, etc.), system protection represents the major challenge which needs to be clarified for DC systems. Advanced AC protection equipment's and methodologies are not sufficient in DC environments. In the current research, fault analysis of 380V DC-Microgrid was performed using PSCAD software. Fault behavior was tested with the application of faults at different locations. All components were connected to the grid through two smart switchgears' which incorporated current and voltage sensors. The recorded data were analyzed and current derivatives were identified as the most crucial parameters for fault detection. Based on that, a credit point concept was set up to filter derivative oscillations in regular operating conditions and to standardize fault indicating values.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131577366","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Optimal sizing of a lithium battery energy storage system for grid-connected photovoltaic systems 并网光伏系统中锂电池储能系统的最优尺寸
2017 IEEE Second International Conference on DC Microgrids (ICDCM) Pub Date : 2017-06-27 DOI: 10.1109/ICDCM.2017.8001106
Jérémy Dulout, B. Jammes, C. Alonso, A. Anvari‐Moghaddam, A. Luna, J. Guerrero
{"title":"Optimal sizing of a lithium battery energy storage system for grid-connected photovoltaic systems","authors":"Jérémy Dulout, B. Jammes, C. Alonso, A. Anvari‐Moghaddam, A. Luna, J. Guerrero","doi":"10.1109/ICDCM.2017.8001106","DOIUrl":"https://doi.org/10.1109/ICDCM.2017.8001106","url":null,"abstract":"This paper proposes a system analysis focused on finding the optimal operating conditions (nominal capacity, cycle depth, current rate, state of charge level) of a lithium battery energy storage system. The purpose of this work is to minimize the cost of the storage system in a renewable DC microgrid. Thus, main stress factors influencing both battery lifetime (calendar and cycling) and performances are described and modelled. Power and energy requirements are also discussed through a probabilistic analysis on some years of real data from the ADREAM photovoltaic building of the LAAS-CNRS in Toulouse, FRANCE.","PeriodicalId":180744,"journal":{"name":"2017 IEEE Second International Conference on DC Microgrids (ICDCM)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124851634","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 35
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书