2019 IEEE Holm Conference on Electrical Contacts最新文献

筛选
英文 中文
Measuring Joint Resistances of Power Connections with Stranded Conductors – Fundamentals, Principles and Common Reasons for Measurement Errors 用绞合导体测量电力连接的联合电阻。测量误差的基本原理、原理和常见原因
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8923666
Christian Hildmann, Stephan Schlegel, S. Grossmann, Carina Schmidt
{"title":"Measuring Joint Resistances of Power Connections with Stranded Conductors – Fundamentals, Principles and Common Reasons for Measurement Errors","authors":"Christian Hildmann, Stephan Schlegel, S. Grossmann, Carina Schmidt","doi":"10.1109/HOLM.2019.8923666","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8923666","url":null,"abstract":"Measuring the joint resistance of power connections with stranded conductors may be a challenging task. Generally, to apply four-terminal sensing is state of the art. Depending on the type of conductor and connection, the suitable type of current feed-in and potential tap has to be considered carefully. Especially tapping the potential correctly is one of the main issues for an accurate and repeatable measurement of joint resistance. The paper therefore summarizes the common methods to measure the joint resistance of power connections with stranded conductors. Further, it presents options for the electrical modeling of connections as well as conductors and compares the measurement methods theoretically. By the means of chosen examples, differences between the measured and the actual joint resistance are shown and discussed. Thereby, the influence of the coaction of conductor and connections as well as of the test setup is considered. The paper reviews these principle considerations in experiments on chosen power connections. This publication aims to reveal common errors in the joint resistance measurement and gives recommendations how to avoid them.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127164763","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Research on Composite Fretting Behaviour of Au-Plated Copper Wire Spring Contacts Used in Electrical Connectors 电连接器用镀金铜线弹簧触头复合微动性能研究
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8924029
S. Ling, Le Xu, Donghui Li, Sai Wu, G. Zhai
{"title":"Research on Composite Fretting Behaviour of Au-Plated Copper Wire Spring Contacts Used in Electrical Connectors","authors":"S. Ling, Le Xu, Donghui Li, Sai Wu, G. Zhai","doi":"10.1109/HOLM.2019.8924029","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8924029","url":null,"abstract":"Gold-plated copper alloy wire spring contact is widely used in the electrical interconnection system of aviation and aerospace engineering due to its advantages of high quality, high reliability and long life. In order to improve the contact stability and prolong the service time, there is a crossing angle in the axial direction between the cylindrical pin and wire spring. When in the vibration environment, this kind of design structure will lead to the phenomenon of composite fretting at the contact interface. Electrical contact resistance (ECR) can be used as an index of contact performance and, in this paper, its variations with fretting cycles are investigated at different crossing angles based on the vibration test system. Instantaneous ECR as a function of instantaneous contact position is also determined. Surface characteristics of fretted area are analyzed by micro-scale photographs. The degradation mechanisms of contacts under different crossing angles are proposed explicitly. It is clearly revealed that the crossing angle is an important factor for the failure mechanisms and performance degradation of wire spring contacts.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123311405","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Holm 2019 Copyright Page Holm 2019版权页面
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/holm.2019.8924015
{"title":"Holm 2019 Copyright Page","authors":"","doi":"10.1109/holm.2019.8924015","DOIUrl":"https://doi.org/10.1109/holm.2019.8924015","url":null,"abstract":"","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116383812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of Terminal Lubrication on Crimp Reliability 末端润滑对压接可靠性的影响
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8923726
J. Hemond, Marcos Pajuelo, Suvrat Bhargava
{"title":"Influence of Terminal Lubrication on Crimp Reliability","authors":"J. Hemond, Marcos Pajuelo, Suvrat Bhargava","doi":"10.1109/HOLM.2019.8923726","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8923726","url":null,"abstract":"Lubrication is often used to improve a product’s reliability or enhance the life of a tool. However, a poorly designed lubricant, or one that is introduced by error into a critical area, may reduce the reliability of an end-product. This scenario is of special concern when considering the use of lubrication for crimp tooling. A crimped connection has both electrical and mechanical performance which is required to ensure a properly functioning end-product. This work explores the possible implication on the mechanical and electrical performance of a typical die lubricant when used in a crimped connection.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123608480","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
The In-situ Wear of a Hot and Cold Switched Au on Au Coated MWCNT Electrical Contact for a MEMS Switch Application 用于MEMS开关的镀金MWCNT电触点热冷开关的原位磨损
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8923967
J. McBride, T. Bull
{"title":"The In-situ Wear of a Hot and Cold Switched Au on Au Coated MWCNT Electrical Contact for a MEMS Switch Application","authors":"J. McBride, T. Bull","doi":"10.1109/HOLM.2019.8923967","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8923967","url":null,"abstract":"The electrical contacts in metal-metal MEMS switches are normally made from thin (> $1~mu text{m}$) metallic film, e.g., (Au). The low contact force in a MEMS device results in a small area for conduction; to increase the area, a composite contact material has been developed. Sputter coated Au, applied to vertically-aligned multi-walled carbon nanotubes, (Au-MWCNT composite), has been shown to increase contact area and extend switching lifetime by orders of magnitude. In this study the Au-MWCNT composite contact is paired with a Au coated hemisphere contact under a contact force of$150~mu text{N}$, in an In-situ Contact Evolution (ICE) apparatus, to evaluate the durability of the contacts for two DC switching conditions; cold switching, at 4 V, $4~mu text{A}$, ($16mu text{W}$) and hot switching at 4 V, 50 mA (200mW). Under cold switching the contacts are shown to maintain a low stable resistance for 4 Billion cycles. The result leads to a re-evaluation of an established fine transfer model, used to predict switching life times.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114211976","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
A Novel Crimp/Compression Connector Technology 一种新型卷曲/压缩连接器技术
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8923654
R. Timsit, Dmitry Ladin
{"title":"A Novel Crimp/Compression Connector Technology","authors":"R. Timsit, Dmitry Ladin","doi":"10.1109/HOLM.2019.8923654","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8923654","url":null,"abstract":"This paper describes the use of an internal elastic-spring insert in a tubular compression connector of the type used in the electrical utility industry, to maintain a large mechanical contact force with the conductor. The paper reports results of preliminary thermal cycling tests on a compression connector attached to a Drake ACSR conductor and adapted with a simple internal elastic-energy storing device.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134183124","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Study of Silver-graphene Tungsten Material For Low Voltage Electrical Contact 低压触点用银-石墨烯钨材料的研究
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8924028
Hai-Ching Chen, Pengpeng Wang, J. Hernández
{"title":"Study of Silver-graphene Tungsten Material For Low Voltage Electrical Contact","authors":"Hai-Ching Chen, Pengpeng Wang, J. Hernández","doi":"10.1109/HOLM.2019.8924028","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8924028","url":null,"abstract":"Silver tungsten composite material is widely applied in low voltage circuit breakers. AgW50 is a typical composite material, comprised of 50% silver and 50% tungsten in weight. Despite its wide use in low voltage molded case circuit breakers, it still has its challenges when it comes to breaker performance in regards to arcing erosion, welding, and contact resistance. This work is to report a new developed electric contact material, (AgGr)W50 made by silver-graphene composite material with tungsten. Instead of Ag in the conventional electric contact, (AgGr), a new composite material replaces a portion of Ag in the AgW50 material. This study focuses on two different percentage of graphene materials, (AgGr0.3)W50 and (AgGr0.5)W50 for our initial investigation. The partial electrical and mechanical properties of both materials have been identified. The material hardness increased up to 21% with no significant change in the electrical resistivity or density in comparison with conventional AgW50 material. Erosion life testing has shown that (AgGr)W50 exhibited a total mass loss of 3.8% which is the lowest of all tested. Functional testing has shown that arcing energy was reduced by27.1% and 7.4% when testing at 5kA and 65kA respectively as compared to AgW50 material. Metallurgical analysis shows that a unique 2-D graphene structure has been observed from the fractography SEM images of silver-graphene tungsten contacts, which is inherited by (AgGr) composite material. Furthermore (AgGr)W50 microstructure images present great uniform mixing while tungsten distributes in the silver-graphene matrix in comparison with traditional silver tungsten material.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134634619","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A Standardized Reliability Evaluation Framework for Connectors - Stress Levels and Test Recommendations 连接器的标准化可靠性评估框架。应力水平和试验建议
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8923931
H. Rubin, Cindy Han, V. Pascucci, J. Toran, R. Druckenmiller, Michael Lipschutz, Phil Conde, V. Vasudevan, Jyoti Gupta, Yen-Han Oon
{"title":"A Standardized Reliability Evaluation Framework for Connectors - Stress Levels and Test Recommendations","authors":"H. Rubin, Cindy Han, V. Pascucci, J. Toran, R. Druckenmiller, Michael Lipschutz, Phil Conde, V. Vasudevan, Jyoti Gupta, Yen-Han Oon","doi":"10.1109/HOLM.2019.8923931","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8923931","url":null,"abstract":"The iNEMI Connector Reliability TestRecommendations Project was organized to address the need for standardized reliability qualification methods for connectors. In previous work, the team reviewed current standards and defined connector interconnect tiers. Using existing standards as a basis, a generalized protocol for evaluating connector reliability based on the defined connector interconnect tiers and stresses expected in use was proposed.In the current work, the team makes recommendations for specific stress level definitions for connectors used in office/consumer, high-end systems, portable, wireless, and industrial applications. The stress levels are mapped to those expected for connector tier 4. Recommendations are made for test conditions associated with each of the stress levelsIn addition, the project group concluded that with some modifications, the EIA 364-1000 standard, Environmental Test Methodology for Assessing Performance of Electrical Connectors and Sockets used in Controlled Environment Applications, can be extended to connectors intended for use in uncontrolled environments. These modifications include adding dust preconditioning, thermal shock preconditioning, and mechanical shock to the test sequences. The group also identified gaps in current standards/knowledge to help guide future improvement in the recommended testing.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124432748","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Holm 2019 Title Page Holm 2019年首页
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/holm.2019.8923980
{"title":"Holm 2019 Title Page","authors":"","doi":"10.1109/holm.2019.8923980","DOIUrl":"https://doi.org/10.1109/holm.2019.8923980","url":null,"abstract":"","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116995638","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An Estimation Method of Cu-W Arcing Contact Electrical Life of SF6 Circuit Breakers in Making Capacitor Bank 电容器组制造中SF6断路器铜钨电弧接触电寿命的估算方法
2019 IEEE Holm Conference on Electrical Contacts Pub Date : 2019-09-01 DOI: 10.1109/HOLM.2019.8923913
Can Ding, Chengxi Li, Zhao Yuan, Chunhua Fang
{"title":"An Estimation Method of Cu-W Arcing Contact Electrical Life of SF6 Circuit Breakers in Making Capacitor Bank","authors":"Can Ding, Chengxi Li, Zhao Yuan, Chunhua Fang","doi":"10.1109/HOLM.2019.8923913","DOIUrl":"https://doi.org/10.1109/HOLM.2019.8923913","url":null,"abstract":"For an SF6 circuit breaker in capacitor bank making operation, the inrush current may cause serious erosion to its arcing contacts. In order to observe the contact erosion property and electrical life under making process, an arc extinguish chamber of SF6 circuit breaker with Cu-W arcing contacts was designed, and experiments of capacitor bank making were carried out under different experimental conditions. In the experiment under various conditions, the arc duration and inrush current have been recorded, the mass loss has been measured after 100 times of operation, and the mass loss rate and friction coefficient have been calculated. Based on the failure mode of reversed order contacting between arcing and main contacts, an estimation method has been proposed to calculate the electrical life of arcing contact in making operation. This method can be used to support the design of the arcing contacts. Changing the arcing contact geometry and reducing arc energy in making operation will improve electrical life of arcing contact.","PeriodicalId":180269,"journal":{"name":"2019 IEEE Holm Conference on Electrical Contacts","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128649487","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书