Journal of Scientific Instruments最新文献

筛选
英文 中文
A double-beam recording spectrodensitometer. 双光束记录分光密度计。
Journal of Scientific Instruments Pub Date : 1969-12-01 DOI: 10.1088/0022-3735/2/12/433
D Staynov, G Stainov
{"title":"A double-beam recording spectrodensitometer.","authors":"D Staynov, G Stainov","doi":"10.1088/0022-3735/2/12/433","DOIUrl":"https://doi.org/10.1088/0022-3735/2/12/433","url":null,"abstract":"A double-beam recording spectrodensitometer has been constructed to measure the optical density of dry agar electrophoregrammes. The measuring and reference beams are modulated with different frequencies. Two resonance amplifiers separate the signals. The electronic logarithmic recording is independent of the nonlinear characteristics of the valves.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 12","pages":"1114-5"},"PeriodicalIF":0.0,"publicationDate":"1969-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/12/433","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16442759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A high resolution charge and mobility spectrometer for radioactive submicrometre aerosols. 放射性亚微米气溶胶的高分辨率电荷和迁移谱仪。
Journal of Scientific Instruments Pub Date : 1969-12-01 DOI: 10.1088/0022-3735/2/12/301
W J Megaw, A C Wells
{"title":"A high resolution charge and mobility spectrometer for radioactive submicrometre aerosols.","authors":"W J Megaw, A C Wells","doi":"10.1088/0022-3735/2/12/301","DOIUrl":"https://doi.org/10.1088/0022-3735/2/12/301","url":null,"abstract":"A simple and easily constructed spectrometer is described by which it is possible to measure the electrical mobilities of submicrometre radioactive aerosol particles with an estimated absolute accuracy to ±4% and a relative accuracy to ±05%. The resolution of the instrument is 3% in mobility.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 12","pages":"1013-6"},"PeriodicalIF":0.0,"publicationDate":"1969-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/12/301","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16442756","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Fabrication of extremely fine glass micropipette electrodes. 极细玻璃微移液电极的制造。
Journal of Scientific Instruments Pub Date : 1969-12-01 DOI: 10.1088/0022-3735/2/12/319
T K Chowdhury
{"title":"Fabrication of extremely fine glass micropipette electrodes.","authors":"T K Chowdhury","doi":"10.1088/0022-3735/2/12/319","DOIUrl":"https://doi.org/10.1088/0022-3735/2/12/319","url":null,"abstract":"Glass micropipette electrodes with extremely fine tips and high mechanical rigidity have been fabricated with a semi-automatic pipette-puller. The fabrication involves a two stage pull of a heated glass capillary held horizontally by a pair of non-slip clamps. Air is automatically blown from symmetrically located nozzles on to the softened portion of the capillary at the onset of the second pull. With this technique micropipettes with a relatively short taper and large cone angle at the very tip are produced, which not only possess high mechanical rigidity, but also a fineness at the tip (500 A or less). A special advantage of the large cone angle at the tip is that such an electrode has a much lower electrical impedance than a conventional micropipette electrode with a comparable tip diameter. The size and shape of the micropipette can be easily altered to meet the specific need. The principle of differential vapour pressure has been utilized to fill the micropipettes with the desired electrolytes. A vibration technique for inserting a microelectrode into living cells is also described.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 12","pages":"1087-90"},"PeriodicalIF":0.0,"publicationDate":"1969-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/12/319","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16442758","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 38
An improved conductivity cell for the continuous measurement of sulphur dioxide in the atmosphere. 一种改进的电导率电池,用于连续测量大气中的二氧化硫。
Journal of Scientific Instruments Pub Date : 1969-12-01 DOI: 10.1088/0022-3735/2/12/302
C M Killick
{"title":"An improved conductivity cell for the continuous measurement of sulphur dioxide in the atmosphere.","authors":"C M Killick","doi":"10.1088/0022-3735/2/12/302","DOIUrl":"https://doi.org/10.1088/0022-3735/2/12/302","url":null,"abstract":"A conductivity cell incorporating the impingement principle suggested by Nash has been designed to facilitate the continuous measurement of atmospheric sulphur dioxide. The instrument based on this cell is provided with several measuring ranges which can be selected to give full scale deflection from 0·2 to 5 p.p.m. sulphur dioxide.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 12","pages":"1017-20"},"PeriodicalIF":0.0,"publicationDate":"1969-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/12/302","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16442757","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A straight needle-probe for the measurement of blood velocity. 用来测量血流速度的直针探针。
Journal of Scientific Instruments Pub Date : 1969-11-01 DOI: 10.1088/0022-3735/2/11/308
B J Bellhouse, F H Bellhouse, A Gunning
{"title":"A straight needle-probe for the measurement of blood velocity.","authors":"B J Bellhouse, F H Bellhouse, A Gunning","doi":"10.1088/0022-3735/2/11/308","DOIUrl":"https://doi.org/10.1088/0022-3735/2/11/308","url":null,"abstract":"A thin-film gauge to measure instantaneous fluid velocity is described. The element, which consists of a platinum thermometer, is cemented into a straight hypodermic needle of 0·75 mm outside diameter and heated electrically to 10 degc above ambient temperature. Heat is removed by forced convection and is related to instantaneous velocity. Calibrations of the probe in water for various angles of inclination to the stream are obtained and a simple method of detecting reversed flow is described. Identical calibrations in water and blood are found, despite a fourfold difference in kinematic viscosity, and an explanation of this effect is advanced.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 11","pages":"936-8"},"PeriodicalIF":0.0,"publicationDate":"1969-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/11/308","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16432487","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A laser manipulator for surgical use. 手术用激光操纵器
Journal of Scientific Instruments Pub Date : 1969-11-01 DOI: 10.1088/0022-3735/2/11/306
A D Beach
{"title":"A laser manipulator for surgical use.","authors":"A D Beach","doi":"10.1088/0022-3735/2/11/306","DOIUrl":"https://doi.org/10.1088/0022-3735/2/11/306","url":null,"abstract":"A mechanical joint has been devised which gives two degrees of freedom to each of three joints in a laser beam steering linkage. This allows accurate counterbalancing of the system and, in conjunction with a CO2 laser, makes the device suitable for use as a surgical tool in `bloodless surgery'.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 11","pages":"931-2"},"PeriodicalIF":0.0,"publicationDate":"1969-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/11/306","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16432486","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
A density discriminator for use in radiation dosimetry by photographic film. 用照相胶片进行辐射剂量测定的密度鉴别器。
Journal of Scientific Instruments Pub Date : 1969-10-01 DOI: 10.1088/0022-3735/2/10/308
K D Cliff
{"title":"A density discriminator for use in radiation dosimetry by photographic film.","authors":"K D Cliff","doi":"10.1088/0022-3735/2/10/308","DOIUrl":"https://doi.org/10.1088/0022-3735/2/10/308","url":null,"abstract":"A simple and reliable optical density discriminator is described which possesses a high discrimination sensitivity and low drift.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 10","pages":"867-70"},"PeriodicalIF":0.0,"publicationDate":"1969-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/10/308","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16423892","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Programmed random time interval signalling device. 程序随机时间间隔信号装置。
Journal of Scientific Instruments Pub Date : 1969-10-01 DOI: 10.1088/0022-3735/2/10/420
E F Keen, P J Calver
{"title":"Programmed random time interval signalling device.","authors":"E F Keen, P J Calver","doi":"10.1088/0022-3735/2/10/420","DOIUrl":"https://doi.org/10.1088/0022-3735/2/10/420","url":null,"abstract":"The device described in this note is an automatic means of producing audio signals at random time intervals, and was devised for a work-study project. The system used could be adapted easily for other purposes, for example to the automating of biological experiments requiring random stimuli for behaviour patterns, or to the random sampling of items on a conveyor belt. The system may be used with multichannel outputs and other parameters, e.g. the number of items or events can be used instead of time.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 10","pages":"898-9"},"PeriodicalIF":0.0,"publicationDate":"1969-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/10/420","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16423893","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An aid to the use of averaging computers in experimental investigations. 在实验研究中使用平均计算机的辅助工具。
Journal of Scientific Instruments Pub Date : 1969-09-01 DOI: 10.1088/0022-3735/2/9/310
J Hodby
{"title":"An aid to the use of averaging computers in experimental investigations.","authors":"J Hodby","doi":"10.1088/0022-3735/2/9/310","DOIUrl":"https://doi.org/10.1088/0022-3735/2/9/310","url":null,"abstract":"The input analogue-to-digital converters of currently available averaging computers have a finite resolution. It is shown that in the presence of noise of 1/f character, this finite resolution sets an upper limit to the possible improvement of signal-to-noise ratio. This limit can be exceeded only if the d.c. level of the input signal is periodically reset. The performance of an electronic circuit designed to do this automatically is described.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 9","pages":"796-8"},"PeriodicalIF":0.0,"publicationDate":"1969-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/9/310","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16885799","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Micro-step motor. Micro-step马达。
Journal of Scientific Instruments Pub Date : 1969-08-01 DOI: 10.1088/0022-3735/2/8/317
G C Joyce, G C Wilson
{"title":"Micro-step motor.","authors":"G C Joyce, G C Wilson","doi":"10.1088/0022-3735/2/8/317","DOIUrl":"https://doi.org/10.1088/0022-3735/2/8/317","url":null,"abstract":"Abstract : A simple reversible linear motor which steps along a precision track is described. Step size can be varied within the range 0.1 - 5.0 um and final motor position can be adjusted to 0.01 um. More complex versions of the motor and control circuits are also described. The motor uses a piezo-electric tube as the driving element which operates in conjunction with electromagnetic clamps to generate progressive movement. (Author)","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 8","pages":"661-3"},"PeriodicalIF":0.0,"publicationDate":"1969-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/2/8/317","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"16881264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信