Habib Ur Rahman Habib, Shaorong Wang, M. Elmorshedy, Mohamed G. Hussien, A. Waqar
{"title":"Efficient Voltage Profile Based Model-Predictive Control Strategy for Stand-Alone Wind-Integrated Hybrid Microgrid Systems","authors":"Habib Ur Rahman Habib, Shaorong Wang, M. Elmorshedy, Mohamed G. Hussien, A. Waqar","doi":"10.1109/APAP47170.2019.9507385","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9507385","url":null,"abstract":"Future power system depends on penetrating more renewable energy to fulfill the drastic increase in energy demand with reduced carbon emission. Wind energy integration is increasing in worldwide each year. To efficiently investigate a quality voltage for AC loads under wind speed variations, a combined control strategy is proposed in this paper. It consists of PI and model predictive control (MPC) for the three-phase rectifier and interlinking inverter, respectively. The controlled rectifier ensures a constant DC-bus voltage under variable wind speed, while MPC is used to control output AC load voltage under abrupt load changes. Unlike traditional controllers, MPC does not require PI controllers for inner current and outer voltage loop or complex modulation steps. The discrete state-space model of VSI, LC filter, and load currents are used to predict future trends of load voltage for each of eight switching states. The control strategy selects the optimal switching state that reduces the error difference between reference and predicted load voltage. The proposed scheme is tested under perturbation of generation and load parameters. The proposed MPC strategy is compared with the conventional method-based PI controllers. The presented results ensure the effectiveness of the proposed approach with 0.67% THD for the AC output voltage.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"154 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122293160","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"[APAP 2019 Front Matter]","authors":"","doi":"10.1109/apap47170.2019.9225165","DOIUrl":"https://doi.org/10.1109/apap47170.2019.9225165","url":null,"abstract":"","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126942974","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"APAP 2019 Author Index","authors":"","doi":"10.1109/apap47170.2019.9224724","DOIUrl":"https://doi.org/10.1109/apap47170.2019.9224724","url":null,"abstract":"","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125956616","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Multi-Virtual Inertia Coordinated Control Technology for AC/DC Hybrid Micro-Grid","authors":"Lin Yunfeng, F. Lijun, Xia Li, Gao Xueping","doi":"10.1109/APAP47170.2019.9225075","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9225075","url":null,"abstract":"New energy power generation equipment and loads can be connected to AC / DC hybrid microgrid flexibly. In order to achieve system frequency and voltage stability, and make full use of the inertia of energy storage, wind turbines, etc. to enhance the anti-disturbance capability of the system. With the flexibility of power control in the AC/DC hybrid micro-grid, both sides of the AC and DC can achieve mutual support of power. In this paper, a virtual inertial joint control technique is proposed in combination with VSG control and virtual capacitor control. Simulation experiments show that the proposed method can effectively improve AC side damping and reduce voltage, frequency and power oscillation recovery time under given system parameters.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"387 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116642236","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Shuang Song, Yi Yang, Chenqing Wang, Shi Chen, Liangliang Song, Lie Zhang
{"title":"A Ping-Pong Self-detection based Online No-dead-time Detection Method for the Tripping-and-closing Circuit","authors":"Shuang Song, Yi Yang, Chenqing Wang, Shi Chen, Liangliang Song, Lie Zhang","doi":"10.1109/APAP47170.2019.9224851","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9224851","url":null,"abstract":"Currently, the detection of the process layer equipment and circuits between breakers is mainly realized through the control circuit. However, the control circuit cannot detect the status of the tripping-and-closing contacts and straps, leading to the failure of the operation of the process layer equipment. To solve this problem, this paper proposes a ping-pong self-detection based online no-dead-time detection method for the tripping-and-closing circuit. Firstly, the topology structure of the existing tripping-and-closing circuit of protections is improved. A contact of the tripping-and-closing relays and the corresponding optocoupler circuit are added. Then, based on the improved control circuit, the self-detection is completed according to the optocoupler acquisition status by sequentially opening and closing the contact of the tripping-and-closing relays with no need of forming a tripping and closing circuit. The proposed method can improve the reliability of the control circuit, avoiding the failure of the operation of the equipment. The test and on-site pilot validate the effectiveness of the proposed detection method.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124870013","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jianwen Zhao, Jie Sun, Zexin Feng, Jianan Lou, Pu Li, Mengmeng Gao
{"title":"A New Method for Faulty Location in Distribution Systems Based on Wavelet Packet Decomposition and Signal Distance","authors":"Jianwen Zhao, Jie Sun, Zexin Feng, Jianan Lou, Pu Li, Mengmeng Gao","doi":"10.1109/APAP47170.2019.9224669","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9224669","url":null,"abstract":"Aiming at the fault characteristics of single-phase grounding system is not obvious and is susceptible to noise signals, a new method for single-phase ground fault segment location based on wavelet packet and signal distance is proposed. When a single-phase ground fault occurs in the resonant grounding system, the wavelet packet is used to perform multi-layer decomposition of the zero-sequence current after the fault, and after removing the lowest frequency band where the power frequency is located, the wavelet packet decomposition coefficients of each layer are extracted and processed by the signal distance algorithm to form A segment location vector that filters the largest element in the vector to determine the faulty segment. Theoretical analysis and simulation results show that the method is not affected by fault conditions such as transition resistance and fault initial phase angle, and can accurately realize the positioning of small current single-phase ground fault sections.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124938686","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An Identification Method for Sympathetic Inrush Based on Substation-Area Information","authors":"F. Peng, Yiqing Liu, Xingong Cheng","doi":"10.1109/APAP47170.2019.9224970","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9224970","url":null,"abstract":"Sympathetic inrush is a phenomenon that occurs in an in-service transformer (IT) when a nearby transformer is energized. The phenomenon can cause transformer differential protection to maloperate. Identification methods for sympathetic inrush have been proposed to deal with the problem. However, these methods are based on local information from the IT, while sympathetic inrush involves two or more transformers. Therefore, an identification method is proposed based on substation-area information. A substation-area differential current is defined and its second harmonic component is utilized to identify the sympathetic inrush. Simulation results by PSCAD/EMTDC show the proposed method can distinguish sympathetic inrush from internal faults and energization inrush effectively.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124979854","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zhehong Chen, G. Song, Zhenfeng Liang, Wenzheng Li, Z. Fan
{"title":"A Pilot Protection Principle for MMC-HVDC Transmission Lines Based on Charge Balance","authors":"Zhehong Chen, G. Song, Zhenfeng Liang, Wenzheng Li, Z. Fan","doi":"10.1109/APAP47170.2019.9225131","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9225131","url":null,"abstract":"Current differential protection based on Kirchhoff's law has sensitivity problem due to the long-distance DC transmission lines with distributed parameter effect. In this paper, the charge of the DC transmission line under the situations of external and internal faults is analyzed. The feature is that the charge will be injected into the fault point from both sides of the DC line when the internal faults occur, and if the external faults occur, the distributed capacitance of the DC line will be discharged. Then a pilot protection principle based on charge balance is proposed using the polarity of the sum of the charge in a time period. The proposed principle is simple and independent of the parameters of the DC line, and it theoretically suits for both transient process and steady-state process. Finally, an MMC-HVDC transmission system is built in PSCAD/EMTDC, and the simulation results show that the method is reliable and not affected by fault resistance.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125165105","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Novel Phasor Domain Parameter-Free Fault Location Algorithm on Untransposed Transmission Lines","authors":"Wangjun Zhu, Yu Liu, D. Lu, Xiaodong Zheng","doi":"10.1109/APAP47170.2019.9225076","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9225076","url":null,"abstract":"This paper proposes a parameter-free method to locate faults in untransposed transmission lines with asymmetrical tower structures. Best implementation requires synchrophasor voltage and current measurements at both terminals of the line. First, the physical laws that the transmission line should obey before and during faults are described in phasor domain, where the fault location as well as parameters of the line are introduced as an unknown variables. Afterwards, the fault location can be directly solved without knowing exact values of transmission line parameters. Compared to the state-of-the-art parameter-free untransposed line fault location method, this method considers a more general asymmetrical tower structure. Numerical experiments prove that the proposed algorithm is more accurate compared to existing untransposed line fault location method, independent of fault location, types and impedances.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123716320","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Impedance Modeling of D-PMSG Considering Currents Frequency Coupling","authors":"S. Yuan, Z. Hao, Hongyue Ma, J. Shu","doi":"10.1109/APAP47170.2019.9225036","DOIUrl":"https://doi.org/10.1109/APAP47170.2019.9225036","url":null,"abstract":"The impedance-based stability analysis is an effective method used in the analysis of subsynchronous oscillation (SSO) of wind farm. Based on the harmonic linearization theory, the impedance model of grid-connected D-PMSG is proposed, the main contribution is considering the frequency coupling of output currents. Firstly, the frequency coupling characteristic of phase locked loop (PLL) is analyzed. Then, the harmonic components in control loop are calculated. Finally, the impedance of PMSG look inside from PCC is established, and the mechanism of sub/sup-synchronous currents coupling is analyzed quantitatively. Simulation are carried out to verify the correctness of the theoretical analysis.","PeriodicalId":165160,"journal":{"name":"2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115109915","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}