{"title":"Fluorescence lifetime imaging with frequency-domain photon migration measurement","authors":"D. Paithankar, E. Sevick-Muraca","doi":"10.1364/bosd.1996.fg3","DOIUrl":"https://doi.org/10.1364/bosd.1996.fg3","url":null,"abstract":"The feasibility of employing fluorescent contrast agents to perform optical imaging in tissues and other scattering media has been examined through computational studies. Fluorescence lifetime and yield can give crucial information about local metabolite concentration or environmental conditions within tissues. This information can be employed towards disease detection, diagnosis, and treatment if non- invasively quantitated from re-emitted optical signals. However, the problem of inverse image reconstruction of fluorescence yield and lifetime is complicated due to the highly scattering nature of the tissue. In this work, a light propagation model employing the diffusion equation is used to account for the scattering of both the excitation and fluorescent light. Simulated measurements of frequency-domain parameters of fluorescent modulated AC intensity and phase-lag are used as inputs to an inverse image reconstruction algorithm which employs the diffusion model to relate frequency-domain measurements resulting from a modulated input at the phantom periphery. In the inverse image reconstruction algorithm, we employ a Newton-Raphson technique combined with Marquardt algorithm to converge upon the fluorescent properties within the medium. The successful reconstruction of both the fluorescence yield and lifetime in the case of heterogeneous fluorophore distribution within a scattering medium has been demonstrated without a priori information or without the necessity of obtaining \"absence\" images.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128024809","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"How LED Wavelength Effects Accuracy in Pulse Oximetry","authors":"D. McGraw","doi":"10.1364/bosd.1996.ap7","DOIUrl":"https://doi.org/10.1364/bosd.1996.ap7","url":null,"abstract":"Selection of the LED pair which minimizes the pulse oximetry SaO2 measurement sensitivity to variations in emission wavelength is described.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117248688","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jody T. Bruulsema, M. Essenpreis, L. Heinemann, J. Hayward, M. Berger, F. Gries, T. Koschinsky, J. Sandahl-Christiansen, H. Orskov, T. Farrell, M. Patterson, D. Böcker
{"title":"Detection of Changes in Blood Glucose Concentration in vivo with Spatially Resolved Diffuse Reflectance","authors":"Jody T. Bruulsema, M. Essenpreis, L. Heinemann, J. Hayward, M. Berger, F. Gries, T. Koschinsky, J. Sandahl-Christiansen, H. Orskov, T. Farrell, M. Patterson, D. Böcker","doi":"10.1364/bosd.1996.cm1","DOIUrl":"https://doi.org/10.1364/bosd.1996.cm1","url":null,"abstract":"Diabetics would benefit from a device capable of providing continuous non-invasive monitoring of their blood glucose levels. A feasibility study was performed to determine whether a technique applying spatially resolved diffuse reflectance measurements could be used to detect changes in the blood glucose levels of diabetic volunteers by monitoring the tissue reduced scattering coefficient. A correlation was observed between step changes in blood glucose concentration and tissue reduced scattering coefficient in 17 out of 22 subjects. A study on non-diabetic volunteers was used to estimate the physiological baseline noise level.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123344264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Reynolds, F. Laplant, C. A. Thompson, K. Webb, D. Ben‐Amotz
{"title":"Quantitative Raman spectroscopic study of acetonitrile in a scattering medium","authors":"J. Reynolds, F. Laplant, C. A. Thompson, K. Webb, D. Ben‐Amotz","doi":"10.1364/bosd.1996.ft4","DOIUrl":"https://doi.org/10.1364/bosd.1996.ft4","url":null,"abstract":"In this paper we demonstrate the use of Raman spectroscopy to determine the concentration of acetonitrile (CH3CN) dispersed in a water/Intralipid scattering medium. We compare techniques for extracting quantitative information from Raman spectra taken in highly scattering media. This technique has potential for use in noninvasive, in vivo biomedical sensing.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"257 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132631316","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
I. Gannot, A. Gandjbakhche, G. Gannot, P. Fox, H. Koch, R. Bonner
{"title":"Non-invasive Technique for the Diagnosis of Diseased Salivary Glands in situ","authors":"I. Gannot, A. Gandjbakhche, G. Gannot, P. Fox, H. Koch, R. Bonner","doi":"10.1364/bosd.1996.dr3","DOIUrl":"https://doi.org/10.1364/bosd.1996.dr3","url":null,"abstract":"A simulation experiment for 3-D imaging exogenous fluorescinated antibodies that specifically bind to infiltrating lymphocytes in minor salivary glands was carried out. Rhodamine targets embedded in a Delrin disk were covered by Delrin slabs of various thickness. Surface images were obtained for a different target depths and radial distances from laser excitation to target fluorophore. These images were analyzed and compared to theoretical calculations using previously determined scattering and absorption coefficients of the Delrin. Good agreement between experiments and theory was achieved.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126731929","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"APPLICATIONS OF LASER OPTICAL MICROSCOPIC TECHNIQUES IN DECIPHERING DISEASE SPECIFIC MECHANISMS AND DIAGNOSIS","authors":"B. Herman","doi":"10.1364/bosd.1996.ft5","DOIUrl":"https://doi.org/10.1364/bosd.1996.ft5","url":null,"abstract":"Accumulating evidence strongly associates human papillomavirus infection with the development of cervical cancers. However, it has also become increasingly clear that HPV infections of the cervix span a wide clinical spectrum from benign lesions to precancerous lesions, with only a minority of infections resulting in invasive cancers, although the reasons for this are not clear. Longitudinal epidemiologic studies using cytologic methods to detect HPV infection have shown that the majority of women infected with HPV will regress spontaneously. In addition, age-stratified data for rates of HPV positivity from cross-sectional studies also suggest that many women clear the infection spontaneously. These results support the concept that many women may be only transiently infected with HPV during their life span and only in women with persistent HPV infection does cervical cancer progress. In addition to persistence of HPV infection, recent epidemiological studies indicate that the amount of high-risk HPV (viral load or HPV gene copy number) in cervicovaginal epithelial cells may be a risk factor for cervical cancer. Thus, a technique which could detect, genotype and quantitate HPV in smears of cervicovaginal epithelial cells would be of major import in assessment of patient clinical status as well as in epidemiological studies relating HPV infection to cervical cancer.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115058781","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Cerussi, J. Maier, S. Fantini, M. Franceschini, E. Gratton
{"title":"The Frequency-Domain Multi-Distance Method in the Presence of Curved Boundaries","authors":"A. Cerussi, J. Maier, S. Fantini, M. Franceschini, E. Gratton","doi":"10.1364/bosd.1996.ap9","DOIUrl":"https://doi.org/10.1364/bosd.1996.ap9","url":null,"abstract":"We present experiments designed to test the applicability of the frequency-domain semi-infinite multi-distance method to cylindrical boundaries. Material with absorption and reduced scattering coefficients similar to those of tissue exposed to near-infrared light was cast into five cylindrical phantoms ranging in diameter from 4.2 to 10.2 cm, and also into a semi-infinite control. Measurements performed along the long axis of symmetry on the larger diameter cylinders reliably recovered both the absorption and the reduced scattering coefficients within 10% of the control values. Measurements performed along the circumference yielded values for these optical coefficients that differed significantly from the control values. These findings are explained by observing the measured frequency-domain parameters as functions of source-detector separation.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123052252","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Spectrophotometry for the Assessment of Pigmented Skin Lesions.","authors":"V. Wallace, J. Bamber, D. Crawford, P. Mortimer","doi":"10.1364/bosd.1996.ap6","DOIUrl":"https://doi.org/10.1364/bosd.1996.ap6","url":null,"abstract":"Optical reflectance spectra (320- 1 100nm) have been obtained from 121 skin lesions. Features correlated with histology correctly classified 73% benign naevi and 100% malignant melanoma.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"793 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117036466","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Deka, B. Lehnert, N. M. Lehnert, G. Jones, L. Sklar, J. Steinkamp
{"title":"Rapid Analysis of Fluorescence Quenching of FITC Conjugated Antibodies on Individual Cells by Phase-Sensitive Flow Cytometry","authors":"C. Deka, B. Lehnert, N. M. Lehnert, G. Jones, L. Sklar, J. Steinkamp","doi":"10.1364/bosd.1996.ca1","DOIUrl":"https://doi.org/10.1364/bosd.1996.ca1","url":null,"abstract":"We demonstrate a high speed method to analyze the impact of self-quenching on fluorescence lifetimes in individual cells by phase-sensitive flow cytometry, using a model system consisting of FITC (fluorescein isothiocyanate) labeled antimouse Thy 1.2 antibodies bound to murine thymus cells.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128527908","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Maier, A. Cerussi, S. Fantini, M. Franceschini, E. Gratton
{"title":"Quantitative Fluorescence in Tissue-Like Media","authors":"J. Maier, A. Cerussi, S. Fantini, M. Franceschini, E. Gratton","doi":"10.1364/bosd.1996.fg6","DOIUrl":"https://doi.org/10.1364/bosd.1996.fg6","url":null,"abstract":"We present a study focused on quantitative fluorescence in tissues at near-infrared wavelengths. We demonstrate the quantitative description of fluorescence in tissue-like media provided by a model derived from diffusion theory. Based on this model we conclude that the spatial distribution of the fluorescent light does not depend on the lifetime of the probe. We also show that lifetime and quantum yield or probe concentration can be determined in a highly scattering medium using frequency-domain techniques, without the use of a reference probe.","PeriodicalId":162016,"journal":{"name":"Biomedical Optical Spectroscopy and Diagnostics","volume":"207 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122786833","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}