2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)最新文献

筛选
英文 中文
Features extraction of palm vein image using phase symmetry 基于相位对称的手掌静脉图像特征提取
H. Setiawan, E. M. Yuniarno
{"title":"Features extraction of palm vein image using phase symmetry","authors":"H. Setiawan, E. M. Yuniarno","doi":"10.1109/ICICI-BME.2015.7401335","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401335","url":null,"abstract":"In biometric recognition, features extraction is extremely important part. Features extraction is used for the selection process of the most influential features in biometric recognition system. Similarly, the introduction of biometric palm vein image based on where the extraction is done to the veins. In this paper, the writer proposes palm vein features extraction method for biometric recognition process. Two dimensional discrete Fourier transform used to convert the image into the frequency domain and filtered by using log- Gabor before it is extracted using the phase symmetry. From 6 sample of palm vein image being tested, the rate of mean absolute percentage error was 2.6%.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128776926","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Validated visible spectrophotometry for quantitative analysis of pirenoxine in the presence of paraben preservatives in eye drop preparations 有效的可见分光光度法定量分析滴眼液制剂中含有对羟基苯甲酸酯防腐剂的吡诺汀
H. Wasito, C. Phechkrajang
{"title":"Validated visible spectrophotometry for quantitative analysis of pirenoxine in the presence of paraben preservatives in eye drop preparations","authors":"H. Wasito, C. Phechkrajang","doi":"10.1109/ICICI-BME.2015.7401388","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401388","url":null,"abstract":"The aim of this work were to develop and validate a visible spectrophotometry for quantitative analysis of pirenoxine in the presence of methylparaben and propylparaben. The proposed method was also applied for real samples of eye drop preparations. The developed method was validated in terms of linearity, range, accuracy, precision, limits of detection (LOD) and limits of quantification (LOQ) by using standard mixture solutions. Method validation was performed according to the United State Pharmacopeia (USP 36) and International Conference on Harmonization Q2(R1) guidelines for the analytical performance parameters. The results of validation illustrated good linearity with the squares of correlation coefficient (r2) greater than 0.99 in the concentration ranges of 2.0-10.0 μg/mL. The method was accurate with average recovery was 100.6%. The relative standard deviation (RSD) of intra-day and inter-day precission were less than 2.00%. LOD and LOQ were found to be 0.40μg/mL and 1.2μg/mL, respectively. The visible spectrophotometric method was found to be precise, accurate, rapid, simple, and inexpensive. The developed and validated method was suitable for quantitation of pirenoxine in real samples of eye drop preparations and could be transferred to quality control laboratories.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129011729","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Optical spectroscopy of Dy3+ doped Lithium borate glasses for luminescence applications 发光应用中掺Dy3+硼酸锂玻璃的光谱学研究
B. Damdee, K. Kirdsiri, J. Kaewkhao
{"title":"Optical spectroscopy of Dy3+ doped Lithium borate glasses for luminescence applications","authors":"B. Damdee, K. Kirdsiri, J. Kaewkhao","doi":"10.1109/ICICI-BME.2015.7401374","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401374","url":null,"abstract":"Dy<sup>3+</sup> ion embedded in 50Li<sub>2</sub>O : 20CaO : (30-x)B<sub>2</sub>O<sub>3</sub> : xDy<sub>2</sub>O<sub>3</sub> (x = 0.00, 0.10, 0.30, 0.50, and 1.0 mol%) glass matrices are prepared and investigated their optical absorption and photoluminescence (PL) as a function of different concentrations of Dy3+ ions. Based on the Judd-Ofelt theory, three spectral intensity parameters Ωλ (λ = 2, 4, 6) are calculated from absorption spectra. The PL spectra show two intense and one weak band due to <sup>4</sup>F<sub>9/2</sub> → <sup>6</sup>H<sub>15/2</sub> (blue), <sup>6</sup>H<sub>13/2</sub> (yellow) and <sup>6</sup>H<sub>11/2</sub> (red) transitions respectively. For these transitions luminescence properties are studied. With the increase in the concentration of Dy<sup>3+</sup> ions, intensity increases up to 0.5 mol% and then concentration quenching is observed.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130563645","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Electroencephalography (EEG) for detecting acute ischemic stroke 脑电图(EEG)用于检测急性缺血性中风
S. K. Wijaya, C. Badri, J. Misbach, T. Soemardi, V. Sutanno
{"title":"Electroencephalography (EEG) for detecting acute ischemic stroke","authors":"S. K. Wijaya, C. Badri, J. Misbach, T. Soemardi, V. Sutanno","doi":"10.1109/ICICI-BME.2015.7401312","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401312","url":null,"abstract":"Currently, the study of EEG for detecting circulatory blood disorders in the brain, including strokes are being widely investigated. EEGs are widely used to diagnose epilepsy, seizures, Alzheimer's disease, cerebral dysfunctions and degenerative diseases of the brain. The aim of this study was to develop a software tool to enhance the available EEG in type C hospital for diagnosing stroke. Patients were examined using EEG and CT-Scan within 48 hours after the onset. The EEG signals were analyzed using spectral analysis of each channel, Welch analysis for detecting the decrement of frequency and BSI (brain symmetry index) for left and right hemisphere of the brain and other standards clinical examination. These signals were compared with the CT-scan to get abnormalities of the signals. There were some irregularities of the EEG signals in comparisons with CT-scan. All patients were examined stroke based on CT-scan. However, there were examined as normal, epileptic form, and stroke based on EEG readings. All of the BSI calculations were above the healthy subjects (0.042 ±0.005), which indicated that all subject were Acute Ischemic Stroke. While for some readings according to the conventional EEG indicated that 20% of the subjects were normal or within normal conditions. These were consistent with the ratios of power densities that all subjects were abnormal. Even these results were consistence with the CT Scans but they should be extended to more subjects in order to get a better conclusions.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131718407","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Plasmodium vivax classification from digitalization microscopic thick blood film using combination of second order statistical feature extraction and K-Nearest Neighbor (K-NN) classifier method 结合二阶统计特征提取和k -最近邻(K-NN)分类器的数字化显微厚血膜间日疟原虫分类
Farah Zakiyah Rahmanti, Sutojo, Novita Kurnia Ningrum, Niken Kartika Imania, M. Purnomo
{"title":"Plasmodium vivax classification from digitalization microscopic thick blood film using combination of second order statistical feature extraction and K-Nearest Neighbor (K-NN) classifier method","authors":"Farah Zakiyah Rahmanti, Sutojo, Novita Kurnia Ningrum, Niken Kartika Imania, M. Purnomo","doi":"10.1109/ICICI-BME.2015.7401339","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401339","url":null,"abstract":"Malaria disease is one of the most serious public health problem in various tropical countries, included in Indonesia. Data of The Ministry of Health mentioned that Papua, West Papua, and NTT (Nusa Tenggara Timur) are provinces which have the greatest cases of malaria. With high mortality rate, malaria need to be treated as quick as possible. Therefore, the accurate and timely diagnosis of malaria infection is essential to control and to cure the disease. We propose an accurate method to classify plasmodium vivax from digitalization microscopic thick blood film using combination of second order statistic feature extraction and K-Nearest Neighbor (K-NN) classifier method. In this feature extraction, we use GLCM (Gray Level Co-occurrence Matrix) to get contrasts, correlations, energys, and homogeneity values. Those values will be inserted in classification module as an input. We use K-NN classifier method to classify the red blood film are infected by plasmodium vivax or not. This process can also classify plasmodium vivax into thropozoit, schizont, and gametocytes. Based on the result of experiments, the combination of second order statistical and K-NN has a high accuracy for classifying plasmodium vivax with average accuracy 95%.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114200814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Polyphonic signal analysis using Cross-correlation on sasando 用互关法分析多音信号
L. F. Boesday, Y. Suprapto
{"title":"Polyphonic signal analysis using Cross-correlation on sasando","authors":"L. F. Boesday, Y. Suprapto","doi":"10.1109/ICICI-BME.2015.7401340","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401340","url":null,"abstract":"Polyphonic signal analysing process becomes the basic topic of signal analysis currently. Furthermore, analysis on the signal of music is also becomes the part of this topic. The main chosen instrument is sasando. As the matter of fact, this is not only about its characteristic sound but also because of the need for the preservation of this musical instrument which is about getting to be abandoned. This research will apply cross correlation method. Cross correlation method will done through signal comparing. We compare polyphonic signal (chord), which having multiple fundamental frequencies. The compatibility can be obtained from amplitude score as the result of Cross-correlation process.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116557552","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Mobile Monitoring System for Indonesian volcano 印尼火山移动监测系统
M. Evita, M. Djamal, B. Zimanowski, K. Schilling
{"title":"Mobile Monitoring System for Indonesian volcano","authors":"M. Evita, M. Djamal, B. Zimanowski, K. Schilling","doi":"10.1109/ICICI-BME.2015.7401378","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401378","url":null,"abstract":"A new combination between Wireless Sensor Network (WSN), mobile robot and satellite technology for Indonesian volcano monitoring system, Mobile Monitoring System for Indonesian Volcano (MONICA) has been developed. This system divided into two modes: fixed-mode and mobile mode. The first mode has shown a good performance. For a small event of volcano activity, the system only uses power 1 million times lower than the power from existing equipment (seismometer). Bandwidth management technique results in 1 normalized throughput with average delay 6 ms as perfect as quality management technique which detects no false alarm and 100% delivery rate.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122335370","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Nailfold capillaroscopy image processing for morphological parameters measurement 甲襞毛细血管镜图像处理的形态学参数测量
Arya Tama, T. Mengko, H. Zakaria
{"title":"Nailfold capillaroscopy image processing for morphological parameters measurement","authors":"Arya Tama, T. Mengko, H. Zakaria","doi":"10.1109/ICICI-BME.2015.7401358","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401358","url":null,"abstract":"Nailfold capillaroscopy is a non-invasive imaging technique employed to assess the microcirculation of blood capillaries. In this paper, image processing will be designed to measure morphological parameters for each capillary. The processes are pre-processing, binarization, skeleton extraction and skeleton segmentation. The morphological parameters are width of capillary, height of capillary, loop morphology, width of terminal loop, caliber and tortuosity. After the implementation, all the parameters can be measured automatically and the binarization process has accuracy up to 96% based on groundtruth image.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116236672","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Heuristic Steady State Visual Evoked Potential based Brain Computer Interface system for robotic wheelchair application 基于启发式稳态视觉诱发电位的机器人轮椅脑机接口系统
Stephen Andronicus, Nathaniel Chandra Harjanto, Suprijanto, A. Widyotriatmo
{"title":"Heuristic Steady State Visual Evoked Potential based Brain Computer Interface system for robotic wheelchair application","authors":"Stephen Andronicus, Nathaniel Chandra Harjanto, Suprijanto, A. Widyotriatmo","doi":"10.1109/ICICI-BME.2015.7401342","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401342","url":null,"abstract":"Development of Brain Computer Interface (BCI) system to enable connection of human intention directly with automated appliances without going through peripheral muscle these days is increasing as an effort to provide solution for patients with disabilities to do their activity normally. Unfortunately current BCI system still has shortage in complex configuration during electroencephalograph (EEG) measurement that uses large numbers of electrodes causing difficulties for the application of the BCI system especially for common usage. Therefore this study, we conduct research on Steady State Visual Evoked Potential (SSVEP)-based Brain Computer Interface to design BCI system utilizing minimum amount of electrodes which is able to use for robotic wheelchair movement control. The BCI system is design heuristically based from the collected experiment data, utilizing banks of filter for the feature extraction and threshold-voting system for feature classification. Offline evaluation of the designed BCI system shows the average correct classification is 84,94% with Information Transfer Rate (ITR) is 68,9440 bits/min.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114790874","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Fixed-mode of mobile monitoring system for Indonesian volcano 印尼火山移动监测系统的固定模式
M. Evita, M. Djamal, B. Zimanowski, K. Schilling
{"title":"Fixed-mode of mobile monitoring system for Indonesian volcano","authors":"M. Evita, M. Djamal, B. Zimanowski, K. Schilling","doi":"10.1109/ICICI-BME.2015.7401379","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2015.7401379","url":null,"abstract":"A system based on Wireless Sensor Network, Mobile Robot and satellite technology has been proposed to overcome some problems in Indonesian volcano monitoring system. Fixed-mode of this mobile monitoring system for Indonesian volcano (MONICA) has been defined and shown efficiency both in power consumption and bandwidth utilization. In this research, we investigated the application of our system for a strong motion earthquake case, which leads to a big eruption. The simulation result shows that our system could manage the power (total 0.39 kJ with 0.07 mJ when there is no data to be sent) as efficient as the bandwidth (0.98 normalized throughput). To guarantee the system to be adaptive and robust to its environment, a quality of service management has been applied to the system. Transmission process consumed the most energy (0.30 kJ), following by seismic processing (0.06 kJ) and reception process of the data (0.03 kJ). The data delivered 100% as well as there was no false alarm with 1 second alarm detection.","PeriodicalId":158291,"journal":{"name":"2015 4th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129871850","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书