{"title":"\"Mixture Properties of Self-Compacting, High-Performance Concrete\"","authors":"N. Nagamoto, K. Ozawa","doi":"10.14359/6155","DOIUrl":"https://doi.org/10.14359/6155","url":null,"abstract":"The self-compacting concrete, which was developed in 1988 in Japan, can be filled in a formwork without using any vibrators. It is an effective means of ensuring consistent quality in concrete structures, as the human factor in consolidation can be eliminated. This type of concrete has markedly increased deformability without segregation: high deformability is achieved mainly through the use of superplasticizers, while segregation resistance is achieved mainly through viscosity of the mortar or paste components of the concrete. The focus of this study is on experimental assessment of the effects of each component of concrete mixture in self-compacting concrete on the fresh state.","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"110 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117219677","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study on the Ability of Highly-Flowable Concrete to Pass Between Steel Reinforcing Bars","authors":"H. Fujiwara, S. Nagataki, A. Dozono, A. Obatake","doi":"10.14359/6143","DOIUrl":"https://doi.org/10.14359/6143","url":null,"abstract":"","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124531849","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"\"High-Performance Concrete Incorporating Zeolite, Fly Ash and Silica Fume\"","authors":"Sammy Chan, X. Ji","doi":"10.14359/6172","DOIUrl":"https://doi.org/10.14359/6172","url":null,"abstract":"In this research, the effectiveness of zeolite, silica fume and fly ash in making high performance concrete with a strength range between 50 and 120 MPa and a slump around 200 mm (7.8 in) is compared. The test results showed that zeolite could decrease bleeding, and increase marginally the viscosity of concrete without significantly compromising the slump. The results also showed that zeolite, silica, and fly ash could all raise the 7 and 28 day strength of concrete. Test results also showed that zeolite could perform better than fly ash but was inferior to silica fume in terms of increasing strength and improving permeation characteristics.","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127624724","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Carbon Fiber-Reinforced Polymer (CFRP) Tendons Subjected to Combined Axial Load and Harping","authors":"Shuaib H. Ahmad, C. Jerrett, P. Zia","doi":"10.14359/6145","DOIUrl":"https://doi.org/10.14359/6145","url":null,"abstract":"The expanded use of fiber reinforced polymer (FRP) tendons as prestressing and post-tensioning tendons requires that these tendons be subjected to high axial loads while bent or harped around a curved surface. This paper describes the behavior of one type of CFRP tendon when subjected to combined axial loading and harping. Four test series to study the tendon fiber strain distribution and seven test series to study the tendon ultimate strength were conducted. The tendons were subjected to various combinations of axial loading and harping around a curved surface. Test parameters for the ultimate strength tests included tendon axial load, bent angle, and curvature of harping point. Harping points were set to either 1 in (25 mm), 5 in (127 mm), or 20 in (508 mm) radius. Ultimate strength tests included static strength tests and fatigue tests.","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124408565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Minimum Flexural Reinforcements of High-Strength Concrete Beams","authors":"F. Wafa, S. Ashour","doi":"10.14359/6152","DOIUrl":"https://doi.org/10.14359/6152","url":null,"abstract":"This paper presents experimental results of 20 high-strength concrete beams tested in flexure to examine the minimum flexural reinforcement requirement. The variables are the flexural reinforcement ratio and the concrete compressive strength. The flexural reinforcement ratio ranges from .21 to .88%, and the 28 day concrete compressive strength ranges from 45 to 90 MPa. The test results are compared with the minimum reinforcement ratios of both the ACI 318-8889 and 318-95 Codes.","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132311024","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Testing of Fiber-Reinforced Structural Concrete Elements","authors":"S. Mindess, P. Adebar, J. Henley","doi":"10.14359/6149","DOIUrl":"https://doi.org/10.14359/6149","url":null,"abstract":"An experimental study aimed at investigating the influence of hooked steel fibers on improving the structural performance of high strength concrete (HSC) members is described. Six columns were tested to investigate the ability of fibers to prevent premature cover spalling in HSC columns. While the final appearance of the columns was influenced by the presence of fibers, the axial capacity was unaffected. Eight elements constructed with concretes ranging in strength from 25 to 95 MPa were tested under shear dominated loading. The addition of fibers changed the failure mode from brittle shear to more ductile flexure/shear mode (diagonal cracking after significant flexural ductility). Eleven large size beam elements were also tested. Due to the addition of fibers, shear strength increases as high as 117% were observed in these members.","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130465122","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An Experimental Study on High-Strength Concrete Column Strength Subjected to Eccentric Loads","authors":"Jaehoon Lee, Hae-geun Park, Youngshik Park","doi":"10.14359/6159","DOIUrl":"https://doi.org/10.14359/6159","url":null,"abstract":"This paper is a part of a research plan aimed at verification of basic design rules to high-strength concrete columns. A total 24 column specimens were tested to investigate structural behavior and strength of eccentrically loaded reinforced concrete tied columns. The main variables included in this test program were concrete compressive strength, steel amount, eccentricity, and slenderness ratio. The concrete compressive strength varied from 34.9 MPa to 70.4 MPa and the column steel ratios were between 1.1% and 5.5%. The eccentricity was selected for the different failure modes. The column specimens with the same slenderness ratio but with different concrete compressive strength were constructed and tested. Experimentally obtained column strengths were compared with the analytical results by use of an equivalent rectangular stress block, a trapezoidal stress block, and a modified rectangular stress block.","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125577582","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Use of Foamcrete in Southern Africa","authors":"E. Kearsley, H. Mostert","doi":"10.14359/6170","DOIUrl":"https://doi.org/10.14359/6170","url":null,"abstract":"","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121105172","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Resistance of High-Quality Concrete (HQC) to Chloride Ion Penetraion","authors":"T. Naik, F. Gustin, Shiw S. Singh","doi":"10.14359/6169","DOIUrl":"https://doi.org/10.14359/6169","url":null,"abstract":"","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131732028","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Precast Concrete Composite Deck Components for Rehabilitation of Bridges","authors":"Richard N. White","doi":"10.14359/6123","DOIUrl":"https://doi.org/10.14359/6123","url":null,"abstract":"The first part of this paper provides a brief review of the critical issues met in replacing deteriorated bridge decks with precast deck systems, drawing on existing papers published by PCI and ACI. Recommended practices for typical bridge rehabilitation projects are provided. The second topic focuses on the rehabilitation of the Tappan Zee Bridge over the Hudson River near New York City. Results are presented for an experimental program conducted on a 10 m (33 ft) span full-scale lightweight concrete slab-steel beam composite bridge deck unit. Loading history included 10 million cycles of flexural fatigue loading, followed by a flexural load capacity test. Measured values of capacity and mid-span deflection at this ultimate load level are compared with simplified analytical predictions.","PeriodicalId":157779,"journal":{"name":"\"SP-172: High-Performance Concrete - Proceedings: ACI International Conference, Malaysia 1997\"","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132590420","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}