{"title":"A coupled segmentation and registration framework for medical image analysis using robust point matching and active shape model","authors":"Chao Lu, J. Duncan","doi":"10.1109/MMBIA.2012.6164742","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164742","url":null,"abstract":"Image segmentation and non-rigid registration are two widely investigated tasks in medical image analysis. Concurrent segmentation and registration methods have received considerable attention in recent years. While some models have been shown to give interesting results, most of them are either able to improve segmentation results alone or able to correct rigid rotation and translation only. In addition, the previous reported methods require a long waiting time to converge. In this paper, we present a fast coupled approach that performs automatic segmentation and nonrigid registration simultaneously. It can progressively identify the boundaries of several organs of interest based on the achieved transformation, and conversely, accurate knowledge of important structures enables us to achievemore precise nonrigid mapping result. We tested the method on two different applications to validate our approach: prostate image guided radiotherapy on computed tomography (CT) volumes and brain image analysis on magnetic resonance images (MRI). Quantitative analysis of experimental results shows that the segmentation result has promising global and local consistencies with the manual segmentation, and the mapping result outperforms the traditional rigid and nonrigid registration. In addition, the new method is proven to be faster and more efficient than previous reported ones.1","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"247 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122936004","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Robust tumour tracking from 2D imaging using a population-based statistical motion model","authors":"Frank Preiswerk, P. Arnold, B. Fasel, P. Cattin","doi":"10.1109/MMBIA.2012.6164749","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164749","url":null,"abstract":"This paper describes a method for tracking a tumour using the planar projections of fiducial markers as surrogates. The projections can originate from various sources such as a beam-eye view X-ray, a portal imager or a fluoroscope. The two-dimensional position of the fiducial markers in the planar image in conjunction with a population-based statistical motion model is used to accurately predict and track the motion of a target volume during treatment. The basic assumption is that the projected surrogate locations contain valuable information about the in-plane motion of the lesion whereas the statistical motion model helps to describe the unobserved out-of-plane motion of the target volume. We analysed the accuracy with regard to varying the camera position and uncertainty in the measurement of the surrogate positions to simulate image noise and camera registration errors. The experiments showed that the tumour motion can be robustly predicted with an accuracy of 2.6 mm over a wide range of target volumes and treatment field directions despite a measurement error of σ = 2 mm for the fiducials.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122101198","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Robust non-rigid registration and characterization of uncertainty","authors":"F. Janoos, Petter Risholm, W. Wells","doi":"10.1109/MMBIA.2012.6164760","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164760","url":null,"abstract":"The uncertainty in registration of medical images may contain important information in cases where clinical decisions are based on registered data. Posing the registration problem in a Bayesian framework allows characterization of the posterior distribution of the deformation parameters which represents the uncertainty of the registration. Uncertainty estimation approaches are complicated by the need to specify the values of hyper-parameters (HPs) of the underlying registration model, e.g. the regularization weight (tissue stiffness) and image noise variance, which have a significant effect on the shape of the posterior distribution. However, it is difficult to assign these HPs physical meaningful values and they are often specified on an ad-hoc basis. In a Bayesian framework, the marginalization of HPs under a suitable prior distribution is a principled alternative to manually tuning the HP values. This paper presents a fast method for marginalizing the HPs of an elastic registration model using local Laplace approximations. We show the feasibility and the advantage of this method in terms of robustness and convergence speed compared to alternative approaches on a clinical image data-set.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"263 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116022534","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Best linear unbiased estimator for Kalman filter based left ventricle tracking in 3D+T echocardiography","authors":"Engin Dikici, F. Orderud, H. Torp","doi":"10.1109/MMBIA.2012.6164741","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164741","url":null,"abstract":"In this paper, we introduce the best linear unbiased estimator (BLUE) for the detection of endocardial edges in 3D+T echocardiography recordings. The maximum gradient (MG), step criterion (STEP) and max flow/min cut (MFMC) edge detectors have been previously applied for the detection of the endocardial edges. BLUE combines the responses of these 3 base estimators using statistical inferences. First, the base estimator bias and covariance properties are learned for each endocardial surface point at each cardiac cycle position. Then, these statistical properties are utilized to compute an optimal linear combination of the base detectors by BLUE. For the validation, MG, STEP, MFMC and BLUE were each employed in connection to a Kalman tracking frame- work. Comparative analyses showed that BLUE outper- forms the other estimators in surface and volumetric measurement accuracy.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129630075","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sudipto Dolui, Iván C. Salgado Patarroyo, O. Michailovich, Y. Rathi
{"title":"Reconstruction of HARDI using compressed sensing and its application to contrast HARDI","authors":"Sudipto Dolui, Iván C. Salgado Patarroyo, O. Michailovich, Y. Rathi","doi":"10.1109/MMBIA.2012.6164765","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164765","url":null,"abstract":"High angular resolution diffusion imaging (HARDI) is known to excel in delineating multiple diffusion flows through a given location within the white matter of the brain. Unfortunately, many current methods of implementation of HARDI require collecting a relatively large number of diffusion-encoded images, which is in turn translated in prohibitively long acquisition times. As a possible solution to this problem, one can undersample HARDI data by using fewer diffusion-encoding gradients than it is prescribed by the classical sampling theory, while exploiting the tools of compressed sensing (CS). Accordingly, the goal of the present paper is twofold. First, the paper presents a novel CS-based framework for the reconstruction of HARDI data using a reduced set of diffusion-encoding gradients. As opposed to similar studies reported in the literature, the proposed method has been optimized for the Rician statistics of measurement noises, which are known to be prevalent in HARDI, and in fact, in MRI in general. Second, we introduce the concept of rotational invariant Fourier signatures (RIFS), and show how they can be used to generate a composite HARDI contrast, which we refer to as colour-HARDI (cHARDI). Finally, via a series of experiments with both simulated and in vivo MRI data, we demonstrate that the quality and informativeness of the proposed contrast deteriorates little, when used in conjunction with the proposed CS-based reconstruction framework. Thus the present work proposes a way to improve the time efficiency of HARDI, and shows its application to the computation of a new HARDI-based contrast which has a potential to improve the clinical value of this important imaging modality.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"163 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122542493","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
James Martin, J. McClelland, Christopher Thomas, Kate Wildermuth, D. Landau, S. Ourselin, D. Hawkes
{"title":"Motion modelling and motion compensated reconstruction of tumours in cone-beam computed tomography","authors":"James Martin, J. McClelland, Christopher Thomas, Kate Wildermuth, D. Landau, S. Ourselin, D. Hawkes","doi":"10.1109/MMBIA.2012.6164764","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164764","url":null,"abstract":"A method is presented which fits a surrogate-driven motion model to a standard clinically-acquired cone-beam computed tomography scan, taken prior to a fraction of stereotactic body radiotherapy treatment. The motion model can account for motion hysteresis, and is intended to drive gated or tracked radiotherapy treatments. The method can be applied in cases with or without implanted markers. Results with simulated and phantom marker data, and simulated markerless data (based on real patient data) are given.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134145919","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A fiber tracking method guided by volumetric tract segmentation","authors":"Chuyang Ye, P. Bazin, S. Ying, Jerry L Prince","doi":"10.1109/MMBIA.2012.6164744","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164744","url":null,"abstract":"This paper presents a fiber tracking method that solves fiber crossing and avoids anatomically improbable fiber tracts using clinical-quality diffusion tensor images. The method tracks fiber pathways under the guidance of global information from volumetric tract segmentation obtained from the algorithm of diffusion oriented tract segmentation (DOTS). New primary diffusion directions (PDD) are calculated in crossing areas labeled by DOTS, by solving the Euler-Lagrange equation. We replace the PDD field obtained from the tensors with the new PDD field, which we refer to as DOTS-PDD, in crossing areas in tractography. Results on synthetic data and real data demonstrate that the proposed method manages to propagate fiber pathways through crossing area and produce anatomically desirable fibers.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133657054","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Arvind Rao, Alex R. Smith, R. Schultz, T. Roberts, R. Verma
{"title":"Peak Geodesic Concentration: A measure of WM complexity in HARDI","authors":"Arvind Rao, Alex R. Smith, R. Schultz, T. Roberts, R. Verma","doi":"10.1109/MMBIA.2012.6164756","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164756","url":null,"abstract":"We design and evaluate a scalar measure for HARDI data called Geodesic Concentration (GC) that characterizes the integrity of white matter (WM), by quantifying the anisotropic concentration of water diffusion. Mathematically, GC is defined as the concentration relative to the peak, identified in the HARDI model fitted to the data. As GC reflects the degree of directionally coherent diffusion, it is sensitive to the presence of single or multiple fiber populations within a voxel and hence is able to characterize complexity of WM, yielding a unique HARDI based scalar measure that can be used for evaluation of pathology. GC properties are elucidated with the help of simulated data and its applicability to population studies is evaluated on a population of autism patients and controls.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"114 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133565320","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A generalized correlation coefficient: Application to DTI and multi-fiber DTI","authors":"M. Taquet, B. Macq, S. Warfield","doi":"10.1109/MMBIA.2012.6164763","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164763","url":null,"abstract":"Multi-fiber models have been introduced as an efficient and interpretable way of representing the diffusion signal in areas with crossing fibers. However, no metric has been provided to use multi-fiber features in registration. The normalized correlation coefficient is commonly used in registration of scalar images due to its invariance under linear transformations of the intensities. In this paper, we generalize the normalized correlation coefficient for tensor and multi-tensor images. The generalized invariance allows linear transformations of the diffusion eigenvalues in the logarithmic domain. We subsequently use it as a metric for block matching and show that multi-tensor features leverage the accuracy of the matching in areas with crossing fibers.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"110 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116016191","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Iterative segmentation and motion correction for dynamic PET images based on radioactive tracer kinetics","authors":"H. Mirzaalian, A. Saad, G. Hamarneh","doi":"10.1109/MMBIA.2012.6164761","DOIUrl":"https://doi.org/10.1109/MMBIA.2012.6164761","url":null,"abstract":"We propose a novel motion correction approach for dynamic emission tomography images that takes advantage of the underlying compartmental models of tracer kinetics. Our algorithm uses a simultaneous segmentation registration paradigm. The key idea of our approach is that, unlike the standard frame-by-frame (FbF) based registration methods, we avoid choosing a reference frame and essentially create a reference frame for each time step. The references are generated by assigning time activity curves based on the estimated kinetic-modeling parameters to the different regions of the segmentation output. We evaluate the goodness of our method compared with the FbF-based registration approach using medical images with known motion corruption parameters. The results indicate superior performance of our method in terms of the accurate estimation of the motion and the kinetic parameters.","PeriodicalId":157489,"journal":{"name":"2012 IEEE Workshop on Mathematical Methods in Biomedical Image Analysis","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114752834","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}