Journal of electron microscopy technique最新文献

筛选
英文 中文
Preparation by ion milling and TEM investigation of embedded needle-shaped crystals of H-Nb2O5. 离子磨法制备H-Nb2O5针状嵌套晶体及透射电镜研究。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190310
F Krumeich, W Mertin
{"title":"Preparation by ion milling and TEM investigation of embedded needle-shaped crystals of H-Nb2O5.","authors":"F Krumeich,&nbsp;W Mertin","doi":"10.1002/jemt.1060190310","DOIUrl":"https://doi.org/10.1002/jemt.1060190310","url":null,"abstract":"<p><p>A method for preparing needle-shaped and platelike crystals for electron microscopical investigation was elaborated. Crystals of H-Nb2O5 were embedded in a synthetic resin and disks were cut off perpendicular to the desired direction of observation. The thickness of the sample was reduced by planar grinding and then by using a dimple grinder and furthermore by ion milling with argon ions. With the precision ion milling system small crystal areas were selected and subsequently irradiated. The TEM investigations showed that the desired crystallographic orientation was reached and that the crystal structure has been preserved. The contrast of highly resolved images was reduced by an amorphous surface layer which was not removable.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"361-5"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190310","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956929","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Capillary pericytes: perspectives and future trends. 毛细管周细胞:展望与未来趋势。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190308
R G Tilton
{"title":"Capillary pericytes: perspectives and future trends.","authors":"R G Tilton","doi":"10.1002/jemt.1060190308","DOIUrl":"https://doi.org/10.1002/jemt.1060190308","url":null,"abstract":"<p><p>A complete understanding of the microcirculation requires full knowledge of the structure and function of each of the constituent cells, including pericytes. Vascular endothelium and smooth muscle cells have been investigated intensively during the last two decades, but much less is known about the metabolism and function of capillary pericytes. However, the development of new electron microscopy techniques and the application of new cell culture and molecular biology techniques should allow for the rapid elucidation of the cellular biochemistry and the microvascular function and pathology of this ubiquitous capillary cell.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"327-44"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190308","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956927","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 108
The fine structure of blood vessels, Part I. 血管的精细结构,第一部分。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190302
{"title":"The fine structure of blood vessels, Part I.","authors":"","doi":"10.1002/jemt.1060190302","DOIUrl":"https://doi.org/10.1002/jemt.1060190302","url":null,"abstract":"","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"273-383"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190302","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12958604","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quick-freeze, deep-etch studies of endothelial components, with special reference to cytoskeletons and vesicle structures. 内皮成分的速冻、深蚀刻研究,特别涉及细胞骨架和囊泡结构。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190307
T Izumi, Y Shibata, T Yamamoto
{"title":"Quick-freeze, deep-etch studies of endothelial components, with special reference to cytoskeletons and vesicle structures.","authors":"T Izumi,&nbsp;Y Shibata,&nbsp;T Yamamoto","doi":"10.1002/jemt.1060190307","DOIUrl":"https://doi.org/10.1002/jemt.1060190307","url":null,"abstract":"<p><p>A three-dimensional study of the ultrastructure of endothelial cells is helpful in understanding important endothelial functions such as vascular transport and cell permeability. For this purpose, in addition to serial sectioning electron microscopy and high-voltage electron microscopy, the quick-freeze, deep-etching technique also enables us to analyze structures at the molecular level by its high resolution and is useful for three-dimensional morphological studies. Some modifications on the conventional deep-etching method were made in this study to reduce the undesirable aggregation of proteins and salts during etching. Using this technique, we examined the rat aortic endothelium, particularly the membrane structures and cytoskeletons. The luminal surface of the endothelium was covered with a fine filamentous coat, which was anchored to the plasma membrane. In the cytoplasm, actin filaments were prominent and were oriented randomly or in a parallel fashion near the plasma membrane. Of the vesicles seen in the endothelium, some had basket coats of clathrin, and others had striped coats on the cytoplasmic membrane surface. These surface structures of the vesicles suggest the transport mechanism of the vesicles in association with the fine filaments attached to the vesicles.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"316-26"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190307","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956926","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
The endothelial vesicle system in cryofixed frog mesenteric capillaries analysed by ultrathin serial sectioning. 超薄连续切片分析冷冻青蛙肠系膜毛细血管内皮泡系统。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190305
J Frøkjaer-Jensen
{"title":"The endothelial vesicle system in cryofixed frog mesenteric capillaries analysed by ultrathin serial sectioning.","authors":"J Frøkjaer-Jensen","doi":"10.1002/jemt.1060190305","DOIUrl":"https://doi.org/10.1002/jemt.1060190305","url":null,"abstract":"<p><p>Conventional EM sections of chemically fixed capillary endothelial cells reveal numerous apparently free smooth plasmalemmal vesicles. However, the method of ultrathin (less than 150 A) serial sectioning has shown that the smooth vesicle profiles arise merely as a result of the EM thin sectioning of two sets of complex vesicular invaginations from the luminal and abluminal cell surfaces, which end blindly in the cytoplasm. While 50-70% of the total population of vesicular profiles appear to lack connections to the cell surface in conventional (500-700 A thick) EM thin sections less than 1% truly free vesicles can be found by the ultrathin serial section analyses. In the present study it is examined whether similar conclusions apply to endothelial cells which were directly frozen by slam-freezing and subsequently freeze-substituted. The three-dimensional organization of the plasmalemmal vesicular system was analyzed in four series of 19, 18, 13, and 10 ultrathin sections (approximately 110 A thick) of capillaries from frog mesenteries quickly excised from decapitated frogs (Rana pipiens). None of 920 vesicular profiles (diameter 500-1,200 A) which appeared free in individual thin sections of the series represented free vesicles; all profiles either communicated with other vesicles, the cell surface, or in rare cases turned out to be part of cytoplasmic tubular membrane structures. It is concluded that free smooth plasmalemmal vesicles are very rare in rapidly frozen as well as in directly fixed frog capillary endothelium. The volume density of profiles (13-15%), the proportion of apparently free vesicle profiles (70%), and interconnected profiles (20%) were similar to the picture previously found in single EM sections of frog mesenteric capillaries. No transendothelial channels were found in the four series of ultrathin sections of capillaries. However, continuities between the luminal and abluminal cell surfaces were seen in the endothelium of venules. Furthermore, in the ultrathin series of the capillaries, vesicular units belonging to the two sets of invaginations and cytoplasmic tubular membrane structures were in more cases found in very close contact-as fused to share one unit membrane. If this finding is representative for the in vivo situation, it may reflect that the vesicular system represents a highly dynamic system with possibilities for mixing of membranes, cellular traffic of lipid, membrane proteins, and receptors between internal compartments and the cell surfaces, as well as occasional exchange of macromolecules between blood and tissue through rare temporary connections between the two sets of surface invaginations, without actually moving vesicles.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"291-304"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190305","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956924","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 36
Cryofixation of vascular endothelium. 冷冻固定血管内皮。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190304
R C Wagner, S B Andrews
{"title":"Cryofixation of vascular endothelium.","authors":"R C Wagner,&nbsp;S B Andrews","doi":"10.1002/jemt.1060190304","DOIUrl":"https://doi.org/10.1002/jemt.1060190304","url":null,"abstract":"<p><p>Cryofixation refers to the immobilization of tissue components by the rapid removal of heat from the specimen, so that the structure is interred and stabilized in a natural embedding medium, namely, frozen (amorphous or microcrystalline) tissue water. Cryofixation is now often used as a complement to the more traditional fixation methods, especially when the cell structure is delicate or dynamic and may be inaccurately preserved by the slow selective action of chemical fixatives. Vascular endothelial cells are specialized for transcellular transport and for the regulation of blood flow and composition. The dynamic and labile subcellular organization of these cells, presumably reflecting these functional specializations, makes them ideal candidates for cryofixation. Several different types of endothelial cells were directly frozen at temperatures below 20 degrees Kelvin by pressing them against a liquid-helium-cooled block. These samples were subsequently processed for structural analysis by freeze-substitution. Detailed rationales, designs, and protocols are described for both freezing and freeze-substitution. Electron micrographs of cryofixed arterial and venous capillaries (rete mirabile of the American eel), iliac vein (rabbit), and cultured endothelium from the iliac vein (human) reveal that the organization of the characteristic intracellular membrane system of endothelial vesicles is qualitatively similar to that seen in chemically fixed endothelium, especially with regard to the interconnection of clusters of individual vesicles to form elaborate networks. The luminal and abluminal networks are not in communication, at least not in static images. Quantitatively, however, most directly frozen endothelial cells have far fewer vesicular profiles than comparable glutaraldehyde-fixed cells. The differences can be explained by presuming that the rapid action of cryofixation (approximately 1 msec) gives a more accurate picture of the vesicular network because it captures the transient structure of labile or dynamic membranes.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"276-90"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190304","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956923","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Real time computer simulation of transmission electron microscope images with tilted illumination: grain boundary applications. 倾斜照明下透射电子显微镜图像的实时计算机模拟:晶界应用。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190311
W Krakow
{"title":"Real time computer simulation of transmission electron microscope images with tilted illumination: grain boundary applications.","authors":"W Krakow","doi":"10.1002/jemt.1060190311","DOIUrl":"https://doi.org/10.1002/jemt.1060190311","url":null,"abstract":"<p><p>Computer programs have been developed to simulate electron microscope images from digitized graphically represented model structures. Via a television rate image processing system, these programs allow real time, interactive modification of the microscope objective lens parameters, incident beam inclination, and incident beam energy. In addition to explaining the computational methods, the need for using tilted beam illumination is explored to extend microscope resolution. For this study, the subject of grain boundary imaging is analyzed for a copper sigma = 5, 36.9 degrees, (310) tilt boundary with a [001] common rotation axis. The Cu [200] lattice spacings of approximately 1.8A on both sides of the interface cannot be reliably resolved under axial illumination conditions in a 200 kV microscope. Therefore, either tilted beam modes or higher incident beam energies were explored and the types of image features correlated with atomic position data through the digital frame store system.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"366-78"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190311","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956863","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Grain boundary character distributions in Ni-16Cr-9Fe using selected area channeling patterns: methodology and results. Ni-16Cr-9Fe的晶界特征分布:方法和结果。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190309
D C Crawford, G S Was
{"title":"Grain boundary character distributions in Ni-16Cr-9Fe using selected area channeling patterns: methodology and results.","authors":"D C Crawford,&nbsp;G S Was","doi":"10.1002/jemt.1060190309","DOIUrl":"https://doi.org/10.1002/jemt.1060190309","url":null,"abstract":"<p><p>Selected area channeling patterns imaged on an SEM are digitized and displayed on the screen of a Macintosh computer, on which the user selects channeling bands that are measured to determine orientation. Grain boundary misorientations are found using the orientation information for pairs of grains adjacent at grain boundaries, and the boundaries are classified as low angle boundaries (LABs), coincident site lattice boundaries (CSLBs), or general boundaries (GHABs) based on the misorientation information. The technique was implemented to analyze the grain boundary character distributions (GBCDs) in Ni-16Cr-9Fe. The GBCDs of solution annealed material were similar to those expected in an aggregate of randomly oriented polycrystals. However, sequential thermomechanical treatments (5% tensile strain + 945 degrees C:75 min + 2% tensile strain + 890 degrees C:15 h + 3% tensile strain + 890 degrees C:20 h or 9% compressive strain + 890 degrees C:20 h + 9% compressive strain + 890 degrees C:20 h + 3% compressive strain + 890 degrees C:15 h) applied after the solution anneal lowered the proportions of GHABs in the GBCDs from 76-79% to 47-64%. The CSL-enhanced GBCDs of both the tensile-deformed samples and the compression-deformed sample appear to have evolved mainly through impingement of twin and twin-related boundaries during recrystallization; the CSL-enhanced GBCD of a compression-deformed sample appears to have been influenced by grain rotation processes to a greater degree than were the tensile-deformed samples The CSL boundaries in the CSL-enhanced GBCDs were, in general, closer to the exact CSL misorientations than were those in the near-random GBCDs of the solution annealed material. An analysis of the distribution of misorientation axes did not indicate any correlation between grain misorientation texture and GBCD evolution.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"345-60"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190309","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956928","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Lectin and immunolabeling of microvascular endothelia. 凝集素与微血管内皮的免疫标记。
Journal of electron microscopy technique Pub Date : 1991-11-01 DOI: 10.1002/jemt.1060190306
A J Milici, G A Porter
{"title":"Lectin and immunolabeling of microvascular endothelia.","authors":"A J Milici,&nbsp;G A Porter","doi":"10.1002/jemt.1060190306","DOIUrl":"https://doi.org/10.1002/jemt.1060190306","url":null,"abstract":"<p><p>A number of recently developed localization techniques are beginning to be applied in the study of endothelial cells and their structural components. In this article we will review a number of these cytochemical approaches as well as their advantages and disadvantages and their applications. The methods will be presented for processing tissues for either L.R. White embedding or semi-thin and thin frozen sections followed by subsequent lectin and immunolabeling for fluorescence and electron microscopic examination. These techniques are easily applied in the localization of perfused exogenous proteins and of endogenous endothelial-associated proteins. The results that can be obtained from such studies are presented and discussed.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"19 3","pages":"305-15"},"PeriodicalIF":0.0,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060190306","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"12956925","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Computer reconstruction of nucleolar architecture by interactive three-dimensional color display. 交互式三维彩色显示核仁结构的计算机重建。
Journal of electron microscopy technique Pub Date : 1991-08-01 DOI: 10.1002/jemt.1060180404
G Geraud, A Soyer, D Hernandez-Verdun
{"title":"Computer reconstruction of nucleolar architecture by interactive three-dimensional color display.","authors":"G Geraud,&nbsp;A Soyer,&nbsp;D Hernandez-Verdun","doi":"10.1002/jemt.1060180404","DOIUrl":"https://doi.org/10.1002/jemt.1060180404","url":null,"abstract":"<p><p>The first complete three dimensional ultrastructural reconstruction of pancreatic cell nucleoli, was done using EM and computer 3D-assisted reconstruction of serial sections with interactive 3D back-to-front and color display methods based on voxel representation. The purpose of the study was to depict the architecture of the nucleolar components. We obtained information about the location of the nucleolus within the nuclear volume and about the shape and polarity of the 3 main nucleolar territories.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"18 4","pages":"354-9"},"PeriodicalIF":0.0,"publicationDate":"1991-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060180404","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"13080306","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信