2014 IEEE International Ultrasonics Symposium最新文献

筛选
英文 中文
An improved method of determining peak blood velocity 一种测定峰值血流速度的改进方法
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0559
S. Ricci, D. Vilkomerson, R. Matera, P. Tortoli
{"title":"An improved method of determining peak blood velocity","authors":"S. Ricci, D. Vilkomerson, R. Matera, P. Tortoli","doi":"10.1109/ULTSYM.2014.0559","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0559","url":null,"abstract":"The peak blood velocity is used in important diagnostic applications, e.g. for determining the stenosis degree. The peak velocity is typically assessed by detecting the highest frequency in the Doppler spectrum. The selected frequency is then converted to velocity by the Doppler equation. This procedure contains multiple potential sources of error: the peak frequency selection is sensitive to noise and affected by spectral broadening, and the frequency to velocity conversion is altered by the Doppler angle uncertainty. The result is an inaccurate estimate. In this work we propose a new method that removes the aforementioned errors. By exploiting a mathematical model of the Doppler spectrum the exact frequency to be converted to velocity, with no need of broadening compensation, is determined. The angle ambiguity is solved by calculating the Doppler spectra backscattered from two different receive apertures. The proposed methods uses, in transmission and receive, defocused steered waves that produce a wide sample volume. This includes the whole vessel section making the probe positioning quick and easy. The method, validated through Field II simulations and phantom experiments, featured a mean error lower than 1%.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"108 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133261740","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Active induction of microbubbles in flow at T-form bifurcation through acoustic focal points with phase variation 通过相位变化的声焦点在t形分叉处主动诱导流动中的微气泡
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0259
K. Masuda, N. Hosaka, R. Koda, Shinya Miyazawa, T. Mochizuki
{"title":"Active induction of microbubbles in flow at T-form bifurcation through acoustic focal points with phase variation","authors":"K. Masuda, N. Hosaka, R. Koda, Shinya Miyazawa, T. Mochizuki","doi":"10.1109/ULTSYM.2014.0259","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0259","url":null,"abstract":"We have ever reported the method to produce three-dimensional acoustic force field to prevent microbubbles dispersing in flow. However, because produced acoustic force worked only to propel microbubbles in the direction of propagation of ultrasound, there was a limitation in direction to affect the behavior of microbubbles. In this research we examined to produce attractive force toward the transducer by considering phase variation of acoustic field. We used a flat matrix array transducer including 64 PZT elements, which was specially developed to produce a continuous wave. We prepared a T-form bifurcation model as artificial blood vessel, which was difficult to control the course of microbubbles. We produced an acoustic field of two focal points with opposite phase, where the middle of the points covers the bifurcation. As the results, when microbubbles suspension (average diameter of 4 um, density of 2.35 μl/ml) was injected with velocity of 40 mm/s, we confirmed that microbubbles aggregations were produced before reaching the bifurcation point and entered the bifurcation to be propelled to the desired path, where the course of microbubbles corresponded to the middle of the two focal points.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128889649","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design of a minimally invasive low-frequency microtransducer for ultrasonic neuromodulation 用于超声神经调节的微创低频微换能器的设计
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0100
Amit P. Mulgaonkar, Rahul S. Singh, G. Saddik, Ashkan Maccabi, W. Melega, M. Culjat, W. Grundfest
{"title":"Design of a minimally invasive low-frequency microtransducer for ultrasonic neuromodulation","authors":"Amit P. Mulgaonkar, Rahul S. Singh, G. Saddik, Ashkan Maccabi, W. Melega, M. Culjat, W. Grundfest","doi":"10.1109/ULTSYM.2014.0100","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0100","url":null,"abstract":"Studies with low intensity focused ultrasound (LIFU) and other related techniques have recently demonstrated the potential for ultrasound to reversibly modulate neural circuits in a number of different in vivo models. However, accurate acoustic targeting can be complicated by the attenuation and distortion of the acoustic beam during transcranial passage through the cranium. This can potentially complicate basic studies of the effects of targeted ultrasonic neurostimulation. An alternative intervention strategy is to develop ultrasonic neurostimulator probes small enough to be minimally-invasively implanted directly adjacent to target neural structures. Two different configurations of PZT-based low frequency microtransducers were designed, fabricated, and evaluated for such a strategy. Acoustic testing demonstrated evenly collimated acoustic radiation profiles, and a pilot study in a small animal model demonstrated the overall feasibility of this approach.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128904583","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Full-field characterization of surface vibrations in microacoustic components by supercontinuum laser stroboscopic white-light interferometry 超连续介质激光频闪白光干涉法研究微声元件表面振动的全场表征
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0040
L. Lipiainen, K. Kokkonen, S. Novotny, I. Shavrin, H. Ludvigsen, M. Kaivola
{"title":"Full-field characterization of surface vibrations in microacoustic components by supercontinuum laser stroboscopic white-light interferometry","authors":"L. Lipiainen, K. Kokkonen, S. Novotny, I. Shavrin, H. Ludvigsen, M. Kaivola","doi":"10.1109/ULTSYM.2014.0040","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0040","url":null,"abstract":"We present phase-sensitive absolute amplitude measurements of surface vibrations in microacoustic devices using a supercontinuum based stroboscopic white-light interferometer. The setup enables full-field characterization of out-of-plane vibration fields down to sub-100 pm amplitudes and up to GHz range, the highest detectable frequency limited only by the duration of the 300 ps light pulses. The capabilities of the system are demonstrated by measuring a vibration field in a square-plate silicon MEMS resonator at a 3.4 MHz resonance. The maximum vibration amplitude was measured to be 40 nm, and a minimum detectable amplitude limit of less than 100 pm was obtained.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"147 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131289871","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
In-vivo convex array vector flow imaging 体内凸阵列矢量流成像
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0082
J. Jensen, A. Brandt, M. Nielsen
{"title":"In-vivo convex array vector flow imaging","authors":"J. Jensen, A. Brandt, M. Nielsen","doi":"10.1109/ULTSYM.2014.0082","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0082","url":null,"abstract":"In-vivo VFI scans obtained from the abdomen of a human volunteer using a convex array transducers and transverse oscillation vector flow imaging (VFI) are presented. A 3 MHz BK Medical 8820e (Herlev, Denmark) 192-element convex array probe is used with the SARUS experimental ultrasound scanner. A sequence with a 129-line B-mode image is followed by a VFI sequence in 17 directions with 32 emissions in each direction. The pulse repetition frequency was set to 5 kHz, and the intensity and MI were measured with the Acoustic Intensity Measurement System AIMS III (Onda, Sunnyvale, California, USA). The derated Ispta.3 was 79.7 mW/m2 and MI was 1.32, which are within FDA limits for abdominal scans. The right liver lobe of a 28-year healthy volunteer was scanned with a view of the main portal vein and vena cava inferior at a frame rate of 7.4 Hz. Thirty frames were acquired, giving 4 seconds of data. For this volunteer the duration corresponded to roughly 3 heartbeats. The velocities were found at a beam-to-flow angle of 72 ± 21°, where a conventional CFM scan would yield poor results. Three VF images from the same position in the cardiac cycle were investigated and the mean lateral velocities were -0.079, -0.081 and -0.080 m/s showing the consistence of the in-vivo results.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131332857","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Accurate finite element model of equiaxed-grain engineering material for ultrasonic inspection 等轴晶粒工程材料超声检测的精确有限元模型
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0337
Bo Xiao, R. O’Leary, A. Gachagan, Wenqi Li, T. Burnett
{"title":"Accurate finite element model of equiaxed-grain engineering material for ultrasonic inspection","authors":"Bo Xiao, R. O’Leary, A. Gachagan, Wenqi Li, T. Burnett","doi":"10.1109/ULTSYM.2014.0337","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0337","url":null,"abstract":"Finite element (FE) simulation of grained material with equiaxed grain distribution is of interest for the virtual prototyping of array structures and the assessment of signal processing algorithms. Construction of such models can be computationally intensive due to the large number of crystallographic orientations required to represent the material. This paper concentrates on analysis and processing of orientation data in order to establish a computationally efficient 2D FE model whilst maintaining appropriate accuracy of the grained structure. Two approaches for orientation processing are proposed and their performances are compared. Parametric studies show that the trade-off between computational overhead and model accuracy will reach the optimal point when Euler space is segmented with a bin size of 15 degree per Euler phase. A transducer array is then incorporated into the FE model to generate B-scan image of the material. The image is compared with experimental equivalent for FE model validation purpose. The minor difference of images proves that the constructed FE model is accurate, highlighting the potential of the proposed methods for application on other equiaxed-grain materials.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115201545","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Estimation of model parameters characterizing dispersion in ARFI induced shear waves in in vivo human liver ARFI诱导的人体肝脏横波弥散模型参数的估计
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0241
N. Rouze, M. Palmeri, K. Nightingale
{"title":"Estimation of model parameters characterizing dispersion in ARFI induced shear waves in in vivo human liver","authors":"N. Rouze, M. Palmeri, K. Nightingale","doi":"10.1109/ULTSYM.2014.0241","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0241","url":null,"abstract":"We consider the analysis of shear wave dispersion following ARFI excitation in a cohort of 135 Non-Alcoholic Fatty Liver Disease patients traditionally characterized as “difficult-to-image.” Three analysis methods are considered: (1) measuring k(ω) by locating the maximum signal from the two-dimensional Fourier transform (2D-FT) of propagating shear wave data, (2) an extension of this method using model-based sums through 2D-FT data, and (3) shear wave spectroscopy. A linear dispersion model is used to characterize the frequency-dependent phase velocity. The analysis methods are evaluated in terms of robustness as determined by the rate of successful measurements in the patient data, and by the degrees of correlation and bias inherent with each method as determined by viscoelastic FEM validation studies. For these patient data and analysis procedures, although the 2D-FT methods are more robust than the shear wave spectroscopy method, they are also systematically biased. Even so, they can be used can be used to characterize the relative viscoelastic properties of liver.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115401343","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Acoustic filtering of particles in a flow regime 流态中粒子的声波过滤
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0355
Kristoffer Johansen, Torstein Yddal, S. Kotopoulis, M. Postema
{"title":"Acoustic filtering of particles in a flow regime","authors":"Kristoffer Johansen, Torstein Yddal, S. Kotopoulis, M. Postema","doi":"10.1109/ULTSYM.2014.0355","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0355","url":null,"abstract":"Hydroelectric power is a clean source of energy, providing up to 20% of the World's electricity. Nevertheless, hydroelectric power plants are plagued with a common problem: silt. The silt causes damage to turbine blades, which then require repairing or replacing. In this study, we investigated the possibility to filter micron-sized particles from water using ultrasound. We designed a custom-made flow chamber and performed flow simulations and experiments to evaluate its efficacy. We used a 195-kHz ultrasound transducer operating in continuous-wave mode with acoustic output powers up to 12W. Our acoustic simulations showed that it should be possible to force a 200-μm particle over 2cm in flow, using an acoustic pressure of 12 MPa. Our flow simulations showed, that the fluid flow is not drastically decreased with the flow chamber, which was validated by the experimental measurements. The flow was not reduced when the ultrasound was activated. The acoustic filtering was effective between acoustic powers of 2.6 and 6.4W, where the particle concentration in the clean output was statistically significantly lower than the null experiments.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115512804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative study of lithium niobate crystal cuts for use as high-voltage acoustic wave sensors 用于高压声波传感器的铌酸锂晶体切割的比较研究
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0493
N. Patel, D. Branch, S. Cular, E. Schamiloglu
{"title":"Comparative study of lithium niobate crystal cuts for use as high-voltage acoustic wave sensors","authors":"N. Patel, D. Branch, S. Cular, E. Schamiloglu","doi":"10.1109/ULTSYM.2014.0493","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0493","url":null,"abstract":"A comparison study between Y+36° lithium niobate (LiNbO3) and 0° X-cut LiNbO3 was performed to evaluate the influence of crystal cut on the performance of a piezoelectric high-voltage (HV) sensor. The acoustic wave propagation time was monitored prior to, during, and after applying three different HV source types to the crystal. Direct current (DC), alternating current (AC), and pulsed voltages were used. Data show that the voltage-induced shift in the acoustic wave propagation time scales quadratically for DC and AC voltage for the X-cut crystal. For the Y+36° LiNbO3 crystal, the acoustic wave arrival time scales linearly with DC voltage and quadratically with AC voltage. When applying 5 μs voltage pulses to the crystal, the voltage-induced shift scales linearly with voltage for both crystal cuts. Data suggest LiNbO3 has a frequency sensitive response to voltage and the influence from the crystal cut is significant when applying AC and pulsed voltage to the crystal.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124303298","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
FPGA embedded system for ultrasound particle manipulation with Sonotweezers 基于Sonotweezers的超声粒子操纵FPGA嵌入式系统
2014 IEEE International Ultrasonics Symposium Pub Date : 2014-10-23 DOI: 10.1109/ULTSYM.2014.0356
Han Wang, Y. Qiu, C. Démoré, S. Cochran
{"title":"FPGA embedded system for ultrasound particle manipulation with Sonotweezers","authors":"Han Wang, Y. Qiu, C. Démoré, S. Cochran","doi":"10.1109/ULTSYM.2014.0356","DOIUrl":"https://doi.org/10.1109/ULTSYM.2014.0356","url":null,"abstract":"Recent research in acoustic tweezing has mainly focused on the behaviour of devices for specific applications and the fundamental theories of the forces exerted on the target particles. However, compared to optical tweezers, there have been only limited reports about developments and applications of acoustic tweezers at the system level. This paper outlines a novel design of a multichannel electronics system for ultrasonic particle manipulation applications. The development process of this 16-channel embedded-FPGA ultrasonic signal generation system is described and experimental results are presented based on its use with array-based acoustic tweezing devices (Sonotweezers).","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114657129","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信