{"title":"Dynamic characterization of dental implant osseointegration","authors":"Bin-xun Hsieh, T. Công, C. Chen, M. Pan","doi":"10.1109/BME-HUST.2016.7782092","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782092","url":null,"abstract":"This paper presents how the response frequencies of dental implant structure depend on material properties of both interfacial tissue and dental structure during the osseointegration. Firstly, artificial bone block models were used to mimic various dental implant structures (with different vertical heights of alveolar bone and cortical thickness) in clinic. The structural resonance frequencies (RFs) were also measured by a noncontact displacement sensor. The obtained results were compared with corresponding finite element analysis (FEA). Secondly, the designated bone tissues around the implant were investigated through numerical simulation and corresponding measured RFs. A human mandible model was constructed based upon a set of in-vivo dental computerized tomography (CT) images. Both the simulation and experimental results show that with larger vise fixation heights the RFs of dental structure with three cortical thickness (1, 2 and 3mm) range from 6771±4.5 to 7078±17.3 Hz in the mesial-distal (MD) direction, and from 5230±6.3 to 6119±18.0 Hz in the buccal-lingual (BL) direction. Therefore, the same approaches can be used to evaluate healing conditions during the osseointegration stages for the other orientations. Additionally, Using the FEA enables to assess the stiffness of interfacial tissues that influence the RFs of implant structure during the primary stability stage; more precisely the RFs increase gradually to a steady level following bone tissues becoming stiffer. The FEA results indicate that using the RF changes can identify the conditions of osseointegration.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"34 5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125720116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimization of micro-plasma parameters for wound healing","authors":"N. Hien, H. Q. Linh, Liao Jiunn Der","doi":"10.1109/BME-HUST.2016.7782095","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782095","url":null,"abstract":"In recent years, atmospheric micro-plasma has various applications in the biomedical field, including blood coagulation [1], tissue sterilization [2], wound care [3], etc. However, the effect of atmospheric micro-plasma, mainly through particle excited state, and some of the gas molecules to wound healing is still controversy, therefore diagnosis plasma parameters is necessary. In this work, non-thermal N2/Ar microplasma is first measured the average temperature, reactive oxygen species with different percentage of gas addition. Based on these databases, the optimization parameters were chosen to treatment fibroblast cells in vitro study and burn wound in vivo study. The primary results showed that 0.5% N2/Ar micro-plasma exposure at 17 W can particularly be used to enhance the cells proliferation and migration. The cells number increased one and half folds for plasma exposure time of 5 or 10 sec, followed by cell culture for 48 hrs. The cell coverage rate rose 20% for the same plasma exposure time, followed by cell culture for 6 or 12 hrs. Based on the results in vitro study, N2/Ar micro-plasma at 13 W was applied to improve healing on the second degree burn wound mice through the wound area reduction, followed by repairing tissue assessments.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134050368","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Dang Thanh Trung, N. Kien, Tran Duc Hung, Do Chi Hieu, Tran Anh Vu
{"title":"Electrical impedance measurement for assessment of the pork aging: A preliminary study","authors":"Dang Thanh Trung, N. Kien, Tran Duc Hung, Do Chi Hieu, Tran Anh Vu","doi":"10.1109/BME-HUST.2016.7782109","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782109","url":null,"abstract":"This work develops a simple technique to evaluate the sirloin pork quality based on its electrical impedance. The measurement of tissue electrical properties can reveal the quality of meat because tissue has certain electrical characteristics such as impedance and conductivity, which change according to post-mortem time. The preliminary results show that the impedance of pork is reduced by time and increased by measurement frequency. Especially, when pork is washed by potassium nitrate, the impedance is much lower than the impedance of the unwashed fresh one.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116595595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Heart rate variability of internet gaming disorder addicts in emotional states","authors":"D. Hsieh, T. Hsiao","doi":"10.1109/BME-HUST.2016.7782106","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782106","url":null,"abstract":"Internet gaming disorder (IGD) was regarded as behavioral addiction, and the common characteristics of internet addiction (IA) or IGD were craving, tolerance, withdrawal, mood modification, and salience. The fifth version of Diagnostic and Statistical Manual of Mental Disorders, addressed IGD, and also proposed 9 research criteria for IGD in 2013. Emotion was reported one character of IGD, and this study hypothesized that emotion was both a response and an influential factor on IGD. The self-report for emotion and questionnaires (psychological character), and electrocardiography (ECG) (physiological signal) of participants in emotional state were collected and analyzed in a non-invasive manner. An emotional induction experiment using online game film clips was conducted. Nineteen participants were grouped into IGD& high-risk internet addiction group, and 21 were in non-IGD & low-risk internet addiction group. The physiological signal (ECG) was used to study emotional responses of IGD. The sympathetic and parasympathetic activities were obtained from heart rate variability (HRV). The IGD addicts exhibited more positive emotion, and stronger sympathetic activity, but felt weaker physiological activity for online game than non-IGD addicts. Emotion can provide a short-term, quick response and dynamic changes of psychological and physiological information of IGD addicts, and that allowed researcher to develop further application, such as monitoring system, early alarm system, early IGD detection, and even prevention.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"15 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114177669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Archawut, W. Tangsuksant, P. Thumwarin, M. Sangworasil, T. Matsuura
{"title":"Realization of FIR system characterizing eye movement based on electrooculogram","authors":"K. Archawut, W. Tangsuksant, P. Thumwarin, M. Sangworasil, T. Matsuura","doi":"10.1109/BME-HUST.2016.7782088","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782088","url":null,"abstract":"The Electrooculogram (EOG) is one of important bio signals. The EOG is useful for many applications such as some disease analysis or assistive application for some type of disability persons. This paper proposes a new method identifying two eye movements, which are clockwise and counter-clockwise eye rotation movements using impulse response of the Finite Impulse Response (FIR) system characterizing EOGs between two channels. The proposed method consists of the three main processes: 1) EOG signal acquisition, 2) Fourier series approximation of EOG waveform, 3) the feature extraction using impulse response of FIR system characterizing EOGs between two channels. The experimental results show that the proposed method is useful for identifying two eye movements (clockwise and counter-clockwise).","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116602303","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A study on the design and construction of Electronic Apex Locator","authors":"S. Boonyagul, T. Eadsongkram, T. Keawgun","doi":"10.1109/BME-HUST.2016.7782090","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782090","url":null,"abstract":"Electronic Apex Locator (EAL) has been developed to determine the true apical foramen location and working length of root canals in endodontic treatment process. It has been long stories of EAL devices since the principle idea was first reported. Since then, many modified ideas and varieties commercial products of electronic apex locators have been studied and introduced in to markets. However, the prices of commercial EAL are mostly expensive which limit the clinical usages in the under-developing or developing countries. From this economic reason, this project was purposed to study on the design and construction of electronic apex locator which has the low-cost price. The design and construction of this device based on the principle of clinical utilization, microcontroller and electronics knowledge. The In Vitro test, on functions of the prototype compared to the commercial device, was performed in 20 root canals which embedded in artificial oral condition. We found that the percentage error of our product compared to the commercial device was 1.74%. It showed that the prototype of EAL can correctly identify the apex location and calculate the working length for endodontic treatments with has cheaper price than that of the commercial products and meets the main purpose of project.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134119829","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Dao Phuong Nam, Tran Anh Vu, Tran Dinh Thiem, Nguyen Huu Thiet
{"title":"Optimal control for bilateral teleoperation system with variational method","authors":"Dao Phuong Nam, Tran Anh Vu, Tran Dinh Thiem, Nguyen Huu Thiet","doi":"10.1109/BME-HUST.2016.7782107","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782107","url":null,"abstract":"This work develops a systematic state-space approach to linearize the nonlinear bilateral teleoperation system. A feedback control law is proposed using the optimazation control method based on the variation method to stabilize the system. The simulation results using Simulink in Matlab are presented to validate the capability of the control system.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"81 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130467369","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Emotional responses of internet gaming disorder by doing abdominal breathing","authors":"Hong-Ming Ji, D. Hsieh, T. Hsiao","doi":"10.1109/BME-HUST.2016.7782103","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782103","url":null,"abstract":"In 2013, the ninth criteria of Internet Gaming Disorder (IGD) were firstly laid out in the Diagnostic and Statistical Manual for Mental Disorders (DSM-V). It performed that playing online game became the most activity of Internet addiction (IA). In order to discriminate the high-risk IA with IGD (HIGD) and low-risk IA with nonIGD (LIGD), the abdominal breathing (AB) and the emotional Self-Assessment Manikin (SAM) questionnaire were used in this study. Totally 19 HIGD subjects and 21 LIGD subjects were asked to watch the three type films (film1, film2 and film3), and to reply SAM questionnaire before and after AB. The results showed the average (t-test) between the arousal scores in before and after AB for LIGD people under all films (p = .01) and film3 (p = .03). As well, the statically significant difference in distribution (F-test) between the valence scores for HIGD people and LIGD people under film2 (p = .04) and film3 (p = .03). To summarize our results, by doing AB, HIGD people mainly changed their emotional valence, and LIGD people mainly changed their emotional arousal for within study. For between study, the type of film2 can distinguish between HIGD and LIGD people, and AB cannot obvious calmed emotional valence for HIGD people. The valence and arousal scores are the potential indexes for discriminating HIGD and LIGD. AB might play a mediation of emotional responses for IGD subjects. The physiological responses for IGD people are going to be investigated in near future.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129198854","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Using dimension reduction with feature selection to enhance accuracy of tumor classification","authors":"T. H. Dang, T. Pham, H. L. Tran, Quang Le Van","doi":"10.1109/BME-HUST.2016.7782082","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782082","url":null,"abstract":"Gene expression microarray data is one of the most popular for diagnosis of cancer. However, the microarray data have thousands of genes and very few samples, it is crucial to develop techniques to effectively gene selection for analysis. So, dimension reduction is an important issue for analysis, of which principle component analysis (PCA) is one of the frequently used methods, and in the previous works, the top several principle components are selected for modeling according to the descending order of eigenvalues. While in this paper, we argue that not all the first features are useful, but features should be selected form all the components by feature selection methods. We demonstrate a framework for selecting good feature subsets from all the principle components, leading to enhance classifier accuracy rates on the gene expression microarray data. As a case study, we have considered PCA for dimension reduction, decesion tree algorithms (DT) for feature selection, and then Multi Layer Perceptron network (MLP) for classification. Experimental results illustrate that our proposed framework is effective to enhance classification accuracy rates.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131162972","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Monitoring of thrombus formation in mock extracorporeal circulation system using electrical impedance spectroscopy","authors":"D. N. Huu, D. Kikuchi, M. Takei, A. Sapkota","doi":"10.1109/BME-HUST.2016.7782084","DOIUrl":"https://doi.org/10.1109/BME-HUST.2016.7782084","url":null,"abstract":"Extracorporeal blood flow devices such as artificial ventricular assistance devices, heart-lung machines, and etc. are widely used in clinic medicine for many years. However, the thrombus formation is still a major concern for these devices. Hence, thrombus real-time monitoring is very essential in these devices. Currently, there are few studies based on optical, ultrasonic and electrical measurement principles for the real-time thrombus detection in the extracorporeal blood flow circulation. The red blood cells (RBCs) concentration has been measured by using the optical measurement method. However, the optical measurement for thrombus formation is impossible in the case of various biocompatible coating in the channel wall. Additionally, the ultrasonic method has some inherent limitation such as the inability to differentiate air emboli from thrombus. The electrical method seems better alternative to the both methods. Asakura et al. reported thrombus formation detection using permittivity measurement. However, the permittivity based detection has frequency sensitivity. Determining a suitable frequency range for each application is a difficult task as it depends upon the samples and the nature of the progress of the thrombus formation process. Cole-Cole analysis is the method to analyzer properties of blood on whole frequency range by using four parameters of the relaxation frequency, the resistance at zero frequency, the resistance at infinite frequency, and shape factor. In this study, thrombus formation results of the thrombus formation experiment in flowing condition were reported. To compare with the present blood coagulability measurement, Activated Clotting Time (ACT) result was also reported. Additionally, temporal change in coagulation factor fibrinogen quantity was represented to consider its effects on thrombus formation results.","PeriodicalId":147689,"journal":{"name":"2016 International Conference on Biomedical Engineering (BME-HUST)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130140176","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}