Gyula Vainel, D. Staton, F. G. Capponi, G. De Donato, F. Caricchi
{"title":"Thermal modelling of a fractional-slot concentrated-winding Kaman type Axial-Flux Permanent-Magnet machine","authors":"Gyula Vainel, D. Staton, F. G. Capponi, G. De Donato, F. Caricchi","doi":"10.1109/ECCE.2013.6646883","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6646883","url":null,"abstract":"The aim of the paper is to present the thermal modeling of a Kaman type Axial-Flux Permanent-Magnet machine with fractional-slot concentrated-winding. This machine is air-cooled and equipped with specific arrangements to enhance heat dissipation. Thermal paths inside the machine are quite complex and require three-dimensional modelling. This is achieved through a lumped parameter network and subdivision of machine into cuboidal elements. The paper describes how thermal modeling is achieved and compares simulations with experimental results taken from a full scale prototype equipped with a number of thermocouples.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114970132","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zhe Zhang, T. Brekken, K. Rhinefrank, A. Schacher, J. Prudell, E. Hammagren, Pukha Lenee-Bluhm
{"title":"Adaptive damping power take-off control for a three-body wave energy converter","authors":"Zhe Zhang, T. Brekken, K. Rhinefrank, A. Schacher, J. Prudell, E. Hammagren, Pukha Lenee-Bluhm","doi":"10.1109/ECCE.2013.6646718","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6646718","url":null,"abstract":"The performance of the power take-off (PTO) system for a wave energy converter (WEC) depends largely on its control algorithm. This paper presents an adaptive damping control algorithm which improves power capture across a range of sea states. The comparison between this control algorithm and other active control approaches such as linear damping is presented. Short term wave elevation forecasting methods and wave period determination methods are also discussed as pre-requirements for this method. This research is conducted for a novel WEC, developed by Columbia Power Technologies (COLUMBIA POWER). All hydrodynamic models are validated with their 1:7 and 1:33 scale tests.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115154189","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Zhiqiang Wang, Xiaojie Shi, Yang Xue, L. Tolbert, B. Blalock, Fred Wang
{"title":"Design and performance evaluation of overcurrent protection schemes for silicon carbide (SiC) power MOSFETs","authors":"Zhiqiang Wang, Xiaojie Shi, Yang Xue, L. Tolbert, B. Blalock, Fred Wang","doi":"10.1109/ECCE.2013.6647436","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6647436","url":null,"abstract":"Overcurrent protection of silicon carbide (SiC) MOSFETs remains a challenge due to lack of practical knowledge. This paper presents two overcurrent protection methods to improve the reliability and overall cost of the SiC MOSFET based converter. First, a solid state circuit breaker (SSCB) composed primarily by a Si IGBT and a commercial gate driver IC is connected in series with the DC bus to detect and clear overcurrent faults. Second, the desaturation technique using a sensing diode to detect the drain-source voltage under overcurrent faults is implemented as well. The design considerations and potential issues of the protection methods are described and analyzed in detail. A phase-leg configuration based step-down converter is built to evaluate the performance of the proposed protection schemes under various conditions, considering variation of fault type, decoupling capacitance, protection circuit parameters, etc. Finally, a comparison is made in terms of fault response time, temperature dependent characteristics, and applications to help designers select a proper protection method.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115376130","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters","authors":"E. Barrios, A. Ursúa, L. Marroyo, P. Sanchis","doi":"10.1109/ECCE.2013.6647284","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6647284","url":null,"abstract":"Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120979884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sensorless control scheme for ultra high speed switched reluctance machine","authors":"J. Dang, R. Harley","doi":"10.1109/ECCE.2013.6647208","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6647208","url":null,"abstract":"The increasing awareness of higher rotational speeds for certain applications has motivated research into ultra high speed drive systems. The switched reluctance machine (SRM), which is an important member of the high speed machine family, has attracted much attention in recent years. However, there are many challenges to control a SRM at high speed, especially without the help of a position sensor. This paper therefore focuses on speed-sensorless control of a SRM at high speeds. A novel rotor position estimation method is proposed that requires little computational effort. Validation results at high speed are presented with the aid of Ansoft/Maxwell simulation. Finally, a close-loop sensorless control is presented to achieve the full speed range sensorless control.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121337814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"FEA estimation and experimental validation of solid rotor and magnet eddy current loss in single-sided axial flux permanent magnet machines","authors":"Xu Yang, D. Patterson, J. Hudgins, J. Colton","doi":"10.1109/ECCE.2013.6647120","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6647120","url":null,"abstract":"The rotor and magnet loss in single-sided axial flux permanent magnet machines with non-overlapped windings is studied in this paper. FEA estimations of the loss are carried out using both 2-D and 3-D modeling. The rotor and magnet losses are determined separately for stator slot passing and MMF space harmonics from currents in the stator. The segregation of loss between the solid rotor plate and the magnet is addressed. The eddy current loss reduction by magnet segments is discussed as well. The prototype 24 slot/22 pole single-sided AFPMs, fabricated with both single layer and double layer windings are assembled. Methods of loss segregation are illustrated in order to separate the eddy current loss.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127163947","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ji-Tai Han, Chang-Soon Lim, Rae-Young Kim, D. Hyun
{"title":"Non-isolated bidirectional ZVT converter with a single resonant inductor for energy storage system","authors":"Ji-Tai Han, Chang-Soon Lim, Rae-Young Kim, D. Hyun","doi":"10.1109/ECCE.2013.6647453","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6647453","url":null,"abstract":"This paper proposes a non-isolated bidirectional dc-dc converter for use in renewable power generation, fuel cell, battery, electric vehicles (EV), and small scale DC-UPS systems. Compared to the traditional bidirectional dc-dc converters, the proposed converter integrates interleaved synchronous energy flow and soft switching technology. By using a resonant cell, the converter can realize zero-voltage-transition (ZVT) where both the switch and the rectifier diode achieve soft condition without increasing their voltage and current stresses. The proposed converter has the advantages of simple circuitry, reduced size, low cost and high efficiency because of a sing resonant inductor. The operation principle of the converter is analyzed and described. Simulation results of the proposed bidirectional ZVT dc-dc converter are shown to verify its feasibility.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127195078","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. G. Yepes, Ana Vidal, J. Malvar, Ó. López, J. Doval‐Gandoy, F. Freijedo
{"title":"Ineffectiveness of orthogonal axes cross-coupling decoupling technique in dual sequence current control","authors":"A. G. Yepes, Ana Vidal, J. Malvar, Ó. López, J. Doval‐Gandoy, F. Freijedo","doi":"10.1109/ECCE.2013.6646819","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6646819","url":null,"abstract":"Proportional-integral (PI) controllers in a single synchronous reference frame (SRF) are popular for current control in voltage source converters. The most common technique to decouple the cross-coupling between its axes is to add/subtract at the output of the PI controller in each axis the current of the orthogonal axis, multiplied by the plant reactance. In case of imbalance, the single SRF is usually replaced by PI controllers in a pair of SRFs rotating with opposite sequences, which is known as double SRF control (DSRFC). It is generally assumed that, to decouple the axes cross-coupling in each SRF of DSRFC, the same decoupling strategy as for a single SRF structure can be applied. This paper proves that in DSRFC this approach does not produce any improvement.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124837990","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Quasi variable capacitor applied to soft switching inverter for induction heating","authors":"S. Kubota, F. Ito, Y. Shimaoka","doi":"10.1109/ECCE.2013.6647103","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6647103","url":null,"abstract":"In this paper, a quasi-variable capacitor applied to soft switching inverter for induction heating and its novel operation control scheme are presented. The proposed quasi variable capacitor has many advantages, such as wide output power regulation range and outputting at double or triple frequency. Moreover, a stable operation is achieved because all switches are always maintaining a soft switching even if different metal, such as stainless steel, aluminum, ferromagnetic metal and paramagnetic metal are heated respectively. Through the experimental results, the usefulness of the proposed quasi variable capacitor has been proved.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124888903","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ripple minimization in asymmetric multiphase interleaved DC-DC switching converters","authors":"M. Schuck, R. Pilawa-Podgurski","doi":"10.1109/ECCE.2013.6646691","DOIUrl":"https://doi.org/10.1109/ECCE.2013.6646691","url":null,"abstract":"Multiphase dc-dc converters are widely used in power electronics, as they enable the processing of high power by splitting the load-current into multiple phases. Conventional multiphase circuits are supplied by a common source, and the goal is to distribute the processed power evenly between the phases. Ripple minimization can then be performed by shifting the switching operations of each phase by angles of an even distance. However, in recent applications, such as maximum power point (MPP) tracking for solar photovoltaic (PV), multiple converters are supplied by sources that are often restricted to operate at different voltages and currents leading to asymmetric converter operation. To achieve improved ripple cancellation under these conditions, phase-shifting by uneven phase-angles is required. In this work, analytic formulas are derived to obtain suitable angles based on given operating conditions. Moreover, a resulting control technique is presented. Simulations are used to evaluate the performance of the proposed technique in the aforementioned application of MPP tracking. Measurements taken from an experimental prototype, which consists of three dc-dc buck converters, further validate the results.","PeriodicalId":145362,"journal":{"name":"2013 IEEE Energy Conversion Congress and Exposition","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125081709","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}