International Journal of Corrosion最新文献

筛选
英文 中文
Effect of Aging Treatment on Intergranular Corrosion Properties of Ultra-Low Iron 625 Alloy 时效处理对超低铁625合金晶间腐蚀性能的影响
IF 3.1
International Journal of Corrosion Pub Date : 2019-01-02 DOI: 10.1155/2019/9506401
Zhi-yuan Zhu, Yi Sui, A. Dai, Yuan-fei Cai, Ling-Li Xu, Ze-xin Wang, Hong-Mei Chen, X. Shao, Wei Liu
{"title":"Effect of Aging Treatment on Intergranular Corrosion Properties of Ultra-Low Iron 625 Alloy","authors":"Zhi-yuan Zhu, Yi Sui, A. Dai, Yuan-fei Cai, Ling-Li Xu, Ze-xin Wang, Hong-Mei Chen, X. Shao, Wei Liu","doi":"10.1155/2019/9506401","DOIUrl":"https://doi.org/10.1155/2019/9506401","url":null,"abstract":"The microstructures evolution of precipitations for an ultra-low iron Alloy 625 subjected to long term aging treatment at 750°C was investigated using scanning electron microscope (SEM) and X-ray diffraction (XRD). The intergranular corrosion behaviors of Alloy 625 were evaluated by using ASTM G28A. The result shows that the precipitated phase γ′′-Ni3Nb was mainly precipitated at the grain boundaries and twin boundaries. The number and volume fraction of γ′′ increased with the prolonging of aging time. The transformation of γ′′ to δ-Ni3Nb occurred after aging periods of 200 h. The corrosion resistance of Alloy 625 was significantly reduced during aging treatment. The decrease in intergranular corrosion resistance of Alloy 625 was attributed to the dissolution of precipitated phase and chromium depleted zone. The mass loss rate of Alloy 625 after aging treatment is related to the volume of precipitated phase and can be simulated by Johnson-Mehl-Avrami equation.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2019-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/9506401","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42555546","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Prediction Method of Asphalt Pavement Performance and Corrosion Based on Grey System Theory 基于灰色系统理论的沥青路面性能与腐蚀预测方法
IF 3.1
International Journal of Corrosion Pub Date : 2019-01-01 DOI: 10.1155/2019/2534794
Ding-bang Zhang, Xin Li, Yi Zhang, Hang Zhang
{"title":"Prediction Method of Asphalt Pavement Performance and Corrosion Based on Grey System Theory","authors":"Ding-bang Zhang, Xin Li, Yi Zhang, Hang Zhang","doi":"10.1155/2019/2534794","DOIUrl":"https://doi.org/10.1155/2019/2534794","url":null,"abstract":"The Grey system theory is a new mathematical method to predict data changes in the poor data integrity. As a branch of Grey system theory, the GM (1, 1) model is widely used because only small sample data and simple calculations are needed in prediction of engineering project. It is a critical problem to effectively predict the performance and corrosion of asphalt pavement of highway construction due to the inadequacy of highway performance monitoring data. The smoothness, rut, and pavement skid resistance are three important indexes to evaluate the performance and corrosion of asphalt pavement. This paper has established the prediction model and derived prediction equation of asphalt pavement performance according to the GM (1, 1) model method and then listed the calculation equation of residual and the gray absolute correlation degree. Based on the experience of constructed Dalian-Guangzhou expressway in China, the vectors “a” and “b” in the prediction equation of smoothness, rut, and pavement skid resistance have been calculated by using the original monitoring data. The field monitoring data are compared with the predictive data for residual and the gray absolute correlation. The results reveal that the predicted data of the smoothness, rut, and skid resistance are mostly consistent with the monitoring data, the biggest residual of the above three indexes is smaller than 8.09%, and the gray absolute correlation degrees all exceed 0.9, which means the accuracy of the predicted equation is excellent. The calculation method based on GM (1, 1) model can effectively predict the changing performance index of asphalt pavement.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/2534794","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46388743","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Prevention of Reinforcement Corrosion in Concrete by Sodium Lauryl Sulphate: Electrochemical and Gravimetric Investigations 十二烷基硫酸钠预防混凝土中钢筋腐蚀的电化学和重量分析研究
IF 3.1
International Journal of Corrosion Pub Date : 2018-12-02 DOI: 10.1155/2018/9471694
Binsi M. Paulson, Thomas K. Joby, V. P. Raphael, K. S. Shaju
{"title":"Prevention of Reinforcement Corrosion in Concrete by Sodium Lauryl Sulphate: Electrochemical and Gravimetric Investigations","authors":"Binsi M. Paulson, Thomas K. Joby, V. P. Raphael, K. S. Shaju","doi":"10.1155/2018/9471694","DOIUrl":"https://doi.org/10.1155/2018/9471694","url":null,"abstract":"Prolonged corrosion inhibition response of sodium lauryl sulphate (SLS) on steel reinforcement in contaminated concrete was investigated by gravimetric method and electrochemical techniques such as potentiodynamic polarization and electrochemical impedance spectroscopy. Using half cell potential measurements probability of steel reinforcement corrosion was monitored for a period of 480 days. FT-IR spectroscopic analysis of the corroded products deposited on the steel reinforcement revealed the mechanism of corrosion inhibition. Modification in the surface morphology of steel specimens in the concrete was examined by optical microscopy. During the period of investigation (480 days), SLS showed appreciable corrosion inhibition efficiency on the steel reinforcement in concrete.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/9471694","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44726446","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Effect of Stress Corrosion on Relaxation of Large Diameter BGFRP Bars 应力腐蚀对大直径BGFRP筋松弛的影响
IF 3.1
International Journal of Corrosion Pub Date : 2018-12-02 DOI: 10.1155/2018/3418596
Guowei Li, Sidi Kabba Bakarr, Jingqiu Wang, Xue Liu, Cheng-yu Hong
{"title":"Effect of Stress Corrosion on Relaxation of Large Diameter BGFRP Bars","authors":"Guowei Li, Sidi Kabba Bakarr, Jingqiu Wang, Xue Liu, Cheng-yu Hong","doi":"10.1155/2018/3418596","DOIUrl":"https://doi.org/10.1155/2018/3418596","url":null,"abstract":"Fibre reinforced polymer (FRP) rebars do not corrode like steel rebars when they are exposed to moisture such as water. Instead they have been shown to degrade when exposed to alkaline media and, in some cases, acids. It has especially demonstrated extensive deterioration when it has been simultaneously stressed and exposed to harsh environments. This combined effect has been termed as stress corrosion. The effect of stress corrosion on the stress relaxation of large sized prestressed basalt-glass fibre reinforced polymer (BGFRP) bars was analyzed by laboratory experiments. Two stressed bars were submerged in aqueous solutions of acid and alkaline in two separate plastic tanks under constant strain. Stress reduction values were observed over a period of about 7 months. Bars immersed in acid bath had an average stress relaxation of 9.2% and that in the alkali bath was observed to be about 13.4%. These results support earlier assertions that exposure of GFRP bars to alkali media is likely to be detrimental to the long-term durability of the reinforced structure.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/3418596","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46108931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Synergistic Inhibition of Mild Steel Corrosion in Seawater and Acidic Medium by Cathodic Protection and Monodora myristica Using Zinc Anode 阴极保护和肉豆蔻酸锌阳极协同抑制软钢在海水和酸性介质中的腐蚀
IF 3.1
International Journal of Corrosion Pub Date : 2018-11-27 DOI: 10.1155/2018/5648907
I. Ukpong, O. Bamgboye, O. Soriyan
{"title":"Synergistic Inhibition of Mild Steel Corrosion in Seawater and Acidic Medium by Cathodic Protection and Monodora myristica Using Zinc Anode","authors":"I. Ukpong, O. Bamgboye, O. Soriyan","doi":"10.1155/2018/5648907","DOIUrl":"https://doi.org/10.1155/2018/5648907","url":null,"abstract":"The synergistic inhibition of mild steel corrosion in seawater and 0.1M sulphuric acid by the cathodic protection and Monodora myristica was carried out through the weight loss and the linear polarization resistance (LPR) measurement. The results showed that in seawater, the synergism was not too effective for the protection of steel, whereas in 0.1M sulphuric acid, there was a great synergism between cathodic protection and the oil extracts of Monodora myristica, having an efficiency (IE%) of 102.89% at 15 mL of the oil extracts. For the linear polarization resistance (LPR), in most of the cases, there was a slight shift of the corrosion potential (Ecorr) and the open circuit potential (OPC) toward the positive as the volume of the oil extracts increased, thereby causing a change in the cathodic and the anodic Tafel slopes, which showed that the inhibitor is a mixed- type inhibitor. The corrosion current density (icorr) decreases as the volumes of the oil extract increase. Langmuir adsorption isotherm fitted best with an R2 of 1 unit, indicating a good agreement with the experimental data and with Langmuir adsorption isotherm.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/5648907","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42307031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Experimental Assessment of Rebar Corrosion in Concrete Slab Using Ground Penetrating Radar (GPR) 用探地雷达对混凝土板中钢筋腐蚀的实验评估
IF 3.1
International Journal of Corrosion Pub Date : 2018-11-21 DOI: 10.1155/2018/5389829
A. Zaki, M. A. Megat Johari, Wan Muhd Aminuddin Wan Hussin, Y. Jusman
{"title":"Experimental Assessment of Rebar Corrosion in Concrete Slab Using Ground Penetrating Radar (GPR)","authors":"A. Zaki, M. A. Megat Johari, Wan Muhd Aminuddin Wan Hussin, Y. Jusman","doi":"10.1155/2018/5389829","DOIUrl":"https://doi.org/10.1155/2018/5389829","url":null,"abstract":"Corrosion of steel reinforcement is a major cause of structural damage that requires repair or replacement. Early detection of steel corrosion can limit the extent of necessary repairs or replacements and costs associated with the rehabilitation works. The ground penetrating radar (GPR) method has been found to be a useful method for evaluating reinforcement corrosion in existing concrete structures. In this paper, GPR was utilized to assess corrosion of steel reinforcement in a concrete slab. A technique for accelerating reinforcement bar corrosion using direct current (DC) power supply with 5% sodium chloride (NaCl) solution was used to induce corrosion to embedded reinforcement bars (rebars) in this concrete slab. A 2 GHz GPR was used to assess the corrosion of the rebars. The analysis of the results of the GPR data obtained shows that corrosion of the rebars could be effectively localized and assessed.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/5389829","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46009645","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 40
Study on the Electrochemical Performance of Sacrificial Anode Interfered by Alternating Current Voltage 交流电压干扰下牺牲阳极电化学性能的研究
IF 3.1
International Journal of Corrosion Pub Date : 2018-11-05 DOI: 10.1155/2018/1523626
Qing-Miao Ding, Xiao Chu, Tao Shen, Xiaoxiao Yu
{"title":"Study on the Electrochemical Performance of Sacrificial Anode Interfered by Alternating Current Voltage","authors":"Qing-Miao Ding, Xiao Chu, Tao Shen, Xiaoxiao Yu","doi":"10.1155/2018/1523626","DOIUrl":"https://doi.org/10.1155/2018/1523626","url":null,"abstract":"The effect of alternating current (AC) voltage of 0V, 1V, 3V, and 5V on magnesium alloy sacrificial anode electrochemical properties was studied by open circuit potential (OCP) analysis, electrochemical impedance spectroscopy (EIS), and polarization curve measurements. The results demonstrate that the AC voltage has a great effect on the magnesium alloy sacrificial anode. The corrosion control is anode control in the first two days with no AC interference. The stray current accelerates the transmission and diffusion of oxygen, so the corrosion rate under AC interference is higher than that with no AC interference. And the corrosion control becomes cathodic control under AC interference. The corrosion rate of the sacrificial anode is faster and faster as the AC interference voltage increases in the range of 0~5V, while the corrosion inclination is weakened.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/1523626","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47150839","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrochemical Properties of Oxide Scale on Steel Exposed in Saturated Calcium Hydroxide Solutions with or without Chlorides 钢在有或无氯化物的饱和氢氧化钙溶液中氧化皮的电化学性质
IF 3.1
International Journal of Corrosion Pub Date : 2018-10-08 DOI: 10.1155/2018/5623504
J. Ahlström, J. Tidblad, L. Tang, B. Sederholm, S. Leijonmarck
{"title":"Electrochemical Properties of Oxide Scale on Steel Exposed in Saturated Calcium Hydroxide Solutions with or without Chlorides","authors":"J. Ahlström, J. Tidblad, L. Tang, B. Sederholm, S. Leijonmarck","doi":"10.1155/2018/5623504","DOIUrl":"https://doi.org/10.1155/2018/5623504","url":null,"abstract":"The electrochemical properties of various iron oxide scales on steel exposed in saturated calcium hydroxide solutions were investigated. The iron oxide scales were manufactured by different heat treatments and grinding processes and characterized using X-ray diffraction and scanning electron microscope. The electrochemical properties of the scales were assessed by measuring the corrosion potential and using electrochemical impedance spectroscopy and potentiodynamic polarization curves. It was found that wustite and magnetite are less noble compared to hematite but are more effective as cathodic surfaces. The results show that the electrochemical properties of the mill scale can be an important contributing factor in the corrosion of steel in concrete.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/5623504","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44216766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Detection of Reinforcement Corrosion in Reinforced Concrete Structures by Potential Mapping: Theory and Practice 电位映射法检测钢筋混凝土结构中钢筋腐蚀的理论与实践
IF 3.1
International Journal of Corrosion Pub Date : 2018-09-30 DOI: 10.1155/2018/3027825
G. Ebell, A. Burkert, J. Mietz
{"title":"Detection of Reinforcement Corrosion in Reinforced Concrete Structures by Potential Mapping: Theory and Practice","authors":"G. Ebell, A. Burkert, J. Mietz","doi":"10.1155/2018/3027825","DOIUrl":"https://doi.org/10.1155/2018/3027825","url":null,"abstract":"Electrochemical potential mapping according to guideline B3 of DGZfP (German Society for Nondestructive Testing) is a recognized technique for the localization of corroding reinforcing steels. In reinforced concrete structures the measured potentials are not necessarily directly linked to the corrosion likelihood of the reinforcing steel. The measured values may be significantly affected, different from, e.g., stress measurement, by different influences on the potential formation at the phase boundary metal/concrete itself as well as the acquisition procedure. Due to the complexity of influencing factors there is a risk that the results are misinterpreted. Therefore, in a training concept firstly the theoretical basics of the test method should be imparted. Then, frequently occurring practical situations of various influencing factors will be made accessible to the participants by a model object specially designed for this purpose. The aim is to impart profound knowledge concerning the characteristics of potential mapping for detecting corrosion of reinforcing steel in order to apply this technique in practice as reliable and economical test method.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/3027825","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48957244","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Anticorrosion Performance of LDH Coating Prepared by CO2 Pressurization Method CO2加压法制备LDH涂层的防腐性能
IF 3.1
International Journal of Corrosion Pub Date : 2018-09-27 DOI: 10.1155/2018/9696549
Xiaochen Zhang, Peng Jiang, Chunyan Zhang, Bateer Buhe, B. Liu, Yang Zhao, Tao Zhang, G. Meng, Fu-hui Wang
{"title":"Anticorrosion Performance of LDH Coating Prepared by CO2 Pressurization Method","authors":"Xiaochen Zhang, Peng Jiang, Chunyan Zhang, Bateer Buhe, B. Liu, Yang Zhao, Tao Zhang, G. Meng, Fu-hui Wang","doi":"10.1155/2018/9696549","DOIUrl":"https://doi.org/10.1155/2018/9696549","url":null,"abstract":"Many surface treatment methods are used to improve the corrosion resistance of magnesium alloys. LDH (layered double hydroxides) conversion coatings are currently found in the most environmentally friendly and pollution-free coatings of magnesium alloy. In this study, the CO2 pressurization method was applied to the preparation of LDH coating on magnesium alloy for the first time. The effect of CO2 pressurization on the formation and corrosion resistance of LDH coating on AZ91D alloy was investigated. The hardness and adhesion were significantly higher on LDH coating in the case of CO2 pressurization than it is in atmospheric pressure. The surface and cross-sectional morphologies show that LDH coating is more compact in the case of CO2 pressurization than with atmospheric pressure. The results of the polarization curve, hydrogen evolution, and immersion tests indicate that the corrosion resistance of the LDH coating prepared by the CO2 pressurization method was significantly improved.","PeriodicalId":13893,"journal":{"name":"International Journal of Corrosion","volume":" ","pages":""},"PeriodicalIF":3.1,"publicationDate":"2018-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/9696549","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43010642","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信