{"title":"Innovations in storage silo floor design and operation","authors":"C. Brule, R. Plant, L. Bartholomew","doi":"10.1109/CITCON.2011.5934559","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934559","url":null,"abstract":"Everything we see and read about today somehow relates to saving the environment. The new “buzz” phrase we hear is “Go Green” when developing new projects. The goal is to design systems to operate at reduced energy levels and reduced filtration requirements while simultaneously improving their performance. In 2005, Lafarge Canada Inc. installed two storage silos with innovative fluidized floor designs for material discharge at their Richmond, B.C. plant. These silos would store flyash and cement. The method of discharge would prove to reduce power, decrease vent requirements, allow material to discharge in a less fluid, well-regulated flow state and ensure complete repetitive emptying. In addition to reducing power consumption during plant operation, it was determined that flyash bulk-trailers were loaded to capacity in less time than with previous systems, thus improving the truck supply capacity for this product. Approximately 40% more capacity was able to be transported by each truck for both flyash and cement increasing throughput, but reducing the number of trucks required per day. Another tangible and unique result of this floor design is the improved homogeneity of these two products over any other types of storage in place on the market.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"118 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125108711","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Calciner design for lower CO and NOx using MI-CFD analysis to optimize “Hot-Reburn” Conditions","authors":"Gina Nance, T. Abbas, T. Lowes, J. Bretz","doi":"10.1109/CITCON.2011.5934552","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934552","url":null,"abstract":"In an effort to reduce production costs, the cement industry is using more and more alternative fuels and raw materials (AFRs) than ever before. Some successful examples show thermal substitution rate (TSR) as high as 90%. Generally, a higher than 20–30 TSR requires detailed analysis of not only combustion aspects of AFRs, but also their impact on emissions, kiln stability and clinker quality. Usually those conditions that provide a more optimum combustion environment both for plants using conventional fuels as well as those using AFRs or a combination of the two mean an increase in NOx emissions. Implementation of traditional low-NOx techniques can have a negative impact on CO/VOC emissions as well as increase deposit build-up potential and cause kiln instabilities. Several alternative NOx reduction methods are available and have been applied within the cement industry. These methods include Selective Non-Catalytic Reduction/Selective Catalytic Reduction (SNCR/SNR) and can provide NOx reduction efficiencies of 40–80% respectively, without significant negative impact on CO/VOC emissions, but at the same time add significant cost to clinker production.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128734764","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Energy efficiency strategies for the cement industry","authors":"F. Mielli","doi":"10.1109/CITCON.2011.5934572","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934572","url":null,"abstract":"The cement manufacturing process is energy intensive. Energy can account for up to 40% of production costs. Energy efficiency initiatives cut these costs by reducing consumption and improving operational output. The objective of this paper is to describe the energy efficiency challenges for the cement industry and present key strategies to tackle these challenges.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129537501","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Continuous X-ray diffraction at the buzzi unicem festus plant","authors":"Alexandra Bequette, S. Dhanjal","doi":"10.1109/CITCON.2011.5934541","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934541","url":null,"abstract":"Mineralogy directly indicates quality of material as well as performance of a cement plant. For example cement alite and belite (together with particle size) give an indication of strength development. The gypsum de-hydration states, e.g. hemi-hydrate and anhydrite ratio indicate cement set times. Cement standards are also mineral dependant as some limit additive levels, such as calcite or cementitious materials such as slag, ash and pozzolans.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123197794","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PLC based enterprise energy management solutions","authors":"Jeffery MacKinnon, S. Warnick, Jesse McDaniel","doi":"10.1109/CITCON.2011.5934568","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934568","url":null,"abstract":"Modern production facilities can potentially have very large electrical loads which translate to expensive production costs. It is recognized that there is value in understanding the primary cost contributions so that a facility can properly manage these resources and refine the operations.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"275 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121316310","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Blending and control systems technologies for cement raw materials revisited - PGNA analyzer application review - An example from Lafarge's Davenport plant in Buffalo, Iowa Usa","authors":"J. Bond, S. Wintz","doi":"10.1109/CITCON.2011.5934557","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934557","url":null,"abstract":"During the past 10 years, the cement-industry application of PGNA on-line analysis in the raw-mix logic of both new plants and as a retrofit has grown from a recent innovation to an industry standard practice. The variety of applications has grown and presents a challenge to designers to choose the optimum raw-mix logic. This paper briefly reviews the applications of analyzers and highlights some applications yet to come. The paper includes an in-depth discussion of one such application at Lafarge's Davenport plant where an analyzer and software substitute for further investment in feed equipment while enabling effective raw-mix control.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124268909","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Clinker kiln optimization: Pushing your equipment to the limit","authors":"William J. Jurado, Tomas Restrepo","doi":"10.1109/CITCON.2011.5934554","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934554","url":null,"abstract":"A methodology for clinker kiln optimization in cement plants is presented in this paper. Mass and energy balances are described as the fundamental optimization tool for the cement industry. Several case studies for specific applications of the proposed methodology are shown.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125800951","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"ARC flash protection enhancements and mitigation","authors":"D. E. Scherry","doi":"10.1109/CITCON.2011.5934571","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934571","url":null,"abstract":"An arc flash is a serious workplace hazard. OSHA requires a workplace free of recognized hazards, of which electricity is a recognized hazard, so OSHA requires electrical work to be done in the deenergized state. The need for an arc flash assessment is in response to the number of injuries from electrical arc flash. Arc flash studies relate energy to current, time, and distance for maintained equipment which reacts to a circuit overcurrent in a timely manner. Benefits of an arc flash assessment are to identify safety hazards, determine appropriate PPE, and determine possible means to reduce the energy by affecting time and/or distance.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128331749","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Online condition monitoring network for critical equipment at Holcim's STE. genevieve plant","authors":"M. Loutfi","doi":"10.1109/CITCON.2011.5934563","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934563","url":null,"abstract":"This paper describes a network architecture for remote monitoring and fault detection of critical rotating equipment. Holcim's Sphinx Monitoring System (SMS) is intended for equipment protection and early prediction of machine defects. SMS is based on a server-client model, where the server maintains a database of equipment configurations and evaluates each target with a unique set of rules that monitor the equipment's function and its integrated components' failure modes. Adaptive software algorithms monitor process and operational changes to tune the analysis criteria for evaluating vibration signals and detecting common machine faults. Network structure, software algorithms and other aspects of the system are further discussed and evaluated against samples of collected data, generated analysis results and physical inspections' outcomes.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130400766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Lubrication and maintenance for key machines in the cement industry","authors":"K. Holz, Renko Balders","doi":"10.1109/CITCON.2011.5934562","DOIUrl":"https://doi.org/10.1109/CITCON.2011.5934562","url":null,"abstract":"Key machines in the cement industry are kilns, grinding equipment like raw and cement mills, roller presses, crushers and clinker cooler.","PeriodicalId":136989,"journal":{"name":"2011 IEEE-IAS/PCA 53rd Cement Industry Technical Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121772345","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}