Smaller, More Efficient Power Supplies - But how 更小、更高效的电源——但如何做到呢
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794531
B. Assow
{"title":"Smaller, More Efficient Power Supplies - But how","authors":"B. Assow","doi":"10.1109/INTLEC.1987.4794531","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794531","url":null,"abstract":"Power supply manufacturers try to make smaller and more efficient power supplies by increasing the switching frequency. Is this necessary? In all known switchmode technologies the flyback is the technology which uses the fewest number of components. By this technique it is possible to make very compact power supplies without using very high switching frequencies. This article is more written after practical design experiences than theoretical calculations.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128321013","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Integrated Load Shedding Project 综合减载项目
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794546
P. Ashar, B.I. Wallner, J. S. Hill, A.Q. Quang
{"title":"Integrated Load Shedding Project","authors":"P. Ashar, B.I. Wallner, J. S. Hill, A.Q. Quang","doi":"10.1109/INTLEC.1987.4794546","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794546","url":null,"abstract":"With the impending energy shortages and the steeply rising costs of constructing new power generation facilities, the electric utilities in the US have found it economically advantageous to encourage major consumers of electricity to curtail usage, mainly during the peak consumption hours between 10 a.m. and 3 p.m. in the summer months. The local telephone companies, while not a very big user of utility power, have a built-in advantage with the availability of standby engine-alternator set in most central offices. The Pacific Bell engineers and the staff of Southern California Edison (SCE-the local electric utility serving a major portion of Southern California) have been negotiating over the ligistics and the economic incentives for implementing this Load Shed Project. This paper attempts to describe the Load Shed Project in terms of its economic merits and the computer-based network which centralizes the control and monitoring process for more than 200 stations.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128472246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Photovoltaic System for Remote Antennas in Satellite Telecommunication 卫星通信远程天线光伏系统
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794575
E. Canuzzi, C. Proietti, C. Fareri
{"title":"Photovoltaic System for Remote Antennas in Satellite Telecommunication","authors":"E. Canuzzi, C. Proietti, C. Fareri","doi":"10.1109/INTLEC.1987.4794575","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794575","url":null,"abstract":"This work, organized from a joint-research between Telespazio S.p.A. and Pragma S.p.A., deals with a photovoltaic energy system installed on the platform roof of Telespazio's building in Rome. The purpose of this experiment is to supply the receiving equipment of a television antenna; this feature is particularly interesting for many other applications too. After a brief description of the photovoltaic system the paper examines, in detail, each component such as: photovoltaic modul, battery, charge regulators. Moreover the authors give some considerations on recording data of most important parameters such as: field current, load voltage and current, insolation, and describes the design procedures of a photovoltaic system for similar purposes.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"113 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124057243","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Initial Results of a New Ongoing Study to Monitor Power Line Disturbances and their Affect on Telephone and Computer Systems of the 1980's 一项正在进行的监测电力线干扰及其对1980年代电话和计算机系统影响的新研究的初步结果
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794603
T. Chandler, D. P. Contostavios
{"title":"Initial Results of a New Ongoing Study to Monitor Power Line Disturbances and their Affect on Telephone and Computer Systems of the 1980's","authors":"T. Chandler, D. P. Contostavios","doi":"10.1109/INTLEC.1987.4794603","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794603","url":null,"abstract":"Voltage disturbances of all types occur in different geographic areas of the United States. The effects of these disturbances on large computers and data processing centers have been published in studies over the last two decades. This paper will evaluate power line disturbances as they affect today's trends toward distributed power, the proliferation smaller computers and lower operating voltages. The effect of line disturbances upon high-speed, low voltage computers will be studied in selected high-technology sites geographically based toward the west with emphasis on Areas not studied before. The preliminary findings of the first 6 sites will be presented during the 1987 Intelec. The study will continue through 1987 and will monitor additional sites. It is anticipated that first results may be inconclusive, and that data from more sites over a longer period will be needed. The final results of the ongoing study will be presented during the 1988 Intelec meeting if acceptable. Using the BMI 4800 Powersope, the latest technology in power line monitors, the initial results on first 6 sites indicate the primary source of power line disturbance that affect telephone and computer system operation are generated internally to the building. These disturbances may be as high as 70% of the overall power line related disruptions to the telephone and computer systems. The BMI data shows actual pictures and graphs of severe waveshape distortion normal mode (line to neutral) and common mode (neutral to ground) impulses and high frequency noise the power line internal to the building.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128941375","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Energy Policy of the French Telecommunications Results of the 1980 - 1985 Plan 法国电信的能源政策是1980 - 1985年计划的结果
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794545
M. Chappey
{"title":"The Energy Policy of the French Telecommunications Results of the 1980 - 1985 Plan","authors":"M. Chappey","doi":"10.1109/INTLEC.1987.4794545","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794545","url":null,"abstract":"The energy policy of the French Télécommunications was defined in 1979. One of it aims was a saving of 171 103 BOE on the 1985 consumption trend. The saving, in fact, was well above the targeted figure and reached 243 103 BOE. The subject of this lecture is to present an analysis of the performances achieved in the 3 classical fields : the transport field, the tertiary field and the industrial field. We will also specify the amount of the investments made and describe some of the technical actions which obtained the best results.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129151568","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Equipment for Attenuation of Mains Transients 市电瞬变衰减设备
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794602
R. Storrs
{"title":"Equipment for Attenuation of Mains Transients","authors":"R. Storrs","doi":"10.1109/INTLEC.1987.4794602","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794602","url":null,"abstract":"","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117215993","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quality of Low-Antimonic Lead Batteries 低锑铅电池的质量
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794627
S. Bråten, H. Raphael, B. Aspmo
{"title":"Quality of Low-Antimonic Lead Batteries","authors":"S. Bråten, H. Raphael, B. Aspmo","doi":"10.1109/INTLEC.1987.4794627","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794627","url":null,"abstract":"Research and experience have shown that cell voltage plays a significant role for the service lifetime of constantly charged high-antimonic lead batteries. It is generally believed that this also occures for newer types low-antimonic lead batteries. Since a battery charger keeps the total voltage at a constant level there will excist deviations between the individual cells. As a consequence of this the Swedish Union of Electricity Boards gives recommendations for tolerable cell voltage deviation within and after the warranty period. Some results of a long time (1976-1981) laboratory test of low-antimonic cells are reported. Late 1981 a series of measurements were performed on a great number of relative new batteries belonging to the Norwegian Telecommunication Administration. These measurements had to be performed with the batteries at normal working conditions. Consequently an automatic measuring technique with a statistical approach had to be used. During the last months of 1986 the measurements of the most interesting batteries were repeated, and capacity-tests on some of the cells were made. This paper presents the measuring method which had to be used due to the pulsating load of the batteries, and gives the results of the two series of measurements. The results are evaluated and some conclusions are drawn.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115653760","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Modular Redundant SMPS System Easy to Expand and Service 模块化冗余SMPS系统,易于扩展和维护
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794568
A. Andersson, Lars Riback
{"title":"A Modular Redundant SMPS System Easy to Expand and Service","authors":"A. Andersson, Lars Riback","doi":"10.1109/INTLEC.1987.4794568","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794568","url":null,"abstract":"The ever increasing complexity of electronic systems together with higher requirements on availability is continuously increasing the interest in redundant power supplies. This paper will describe the system design considerations for a Modular Multiple Output Redundant SMPS System.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115166906","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Monitoring and diagnostics for UPS systems 监测和诊断UPS系统
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794578
H. Gaul, S. Lingaya, H. Mickal
{"title":"Monitoring and diagnostics for UPS systems","authors":"H. Gaul, S. Lingaya, H. Mickal","doi":"10.1109/INTLEC.1987.4794578","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794578","url":null,"abstract":"A description is given of a monitoring and diagnostics system for UPS systems. The process data of the individual units are acquired and condensed by local computers. These data are transmitted via a serial bus to a central PC which displays them in the form of a block diagram and, in the event of a fault, analyses the cause of the trouble.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125729336","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Optimum Sized Air Channels for Natural Convection Cooling 自然对流冷却的最佳尺寸空气通道
INTELEC '87 - The Ninth International Telecommunications Energy Conference Pub Date : 1987-06-14 DOI: 10.1109/INTLEC.1987.4794618
A. Malhammar
{"title":"Optimum Sized Air Channels for Natural Convection Cooling","authors":"A. Malhammar","doi":"10.1109/INTLEC.1987.4794618","DOIUrl":"https://doi.org/10.1109/INTLEC.1987.4794618","url":null,"abstract":"Natural convection cooling is widely used for temperature control in electronic equipment. The amount of heat that can be removed is determined by three factors: the temperature difference, the cooling area and the heat transfer coefficient. Heat transfer calculations for idealized cases are relatively easy and the results of these often give a good lead for the mechanical design of electronic equipment. As it is a general desire to keep the volume of an equipment at a minimum, one of the most important aims is to maximize the heat dissipation in a volume for a given temperature difference. The optimum spacing for PCB:s in cabinets cooled by natural convection will depend on the pattern of air flow through the cabinet. The air flow pattern is also very important for the possibilities to improve heat dissipation with component coolers. The optimum fin spacing for component coolers used with natural convection will vary with many factors but is generally between 5-15 mm.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124393563","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信