{"title":"The new Method for Identifying Demand Consumers with a Reactive Power Consumption Outside the Scope set by the Ministry of Energy","authors":"Maryam Borzouei, M. Babaei","doi":"10.1109/EPDC.2018.8536300","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536300","url":null,"abstract":"With the installation and operation of smart meters in recent years and access to hourly data flow these meters, better understanding and management the Load profile of demand consumers is possible. In this paper, using this possibility, an indicator for identifying subscribers who, despite their reactive consumption and power factor less than 0.9 in different times, do not pay reactive cost, and for the joint distribution company, as a reactive consumer Not identifiable and occupy the power grid capacity, is provided. In this paper, two different scenarios are used to calculate the detriment factor based on the consumer's power factor, from which the consumers that need to be corrected or capacitors are introduced. The analytical results of this approach are presented in this paper for 715 consumers with the primary voltage connection at the level of Tehran's power distribution company.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124540846","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Increasing Redundancy and Cost Reduction to Improve Power Factor and Reduce Harmonic Using Parallel Connection of D-STATCOMs","authors":"Pourya Sarvghadi, A. Yazdian, R. Ghazi","doi":"10.1109/EPDC.2018.8536267","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536267","url":null,"abstract":"The existence of harmonics and low power factor in electrical networks is inevitable. These factors will reduce the network efficiency and service quality to consumers. One way of alleviating such effects is using the line conditioners such as D-STATCOM. As redundancy and cost reduction are important issues in the design of electrical apparatus and networks, in this paper a new scheme comprises two parallel D-STATCOMs is proposed. Hence redundancy and cost reduction are provided while power quality problem i.e. harmonics and power factor are greatly improved. Simulation results for non-linear and inductive loads in 220V voltage are reported and discussed. The obtained results show that the proposed scheme has a proper operation in improving harmonics and power factor of loads.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123792716","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. Ghasemkhani, R. Khalili, B. Zaker, G. Gharehpetian
{"title":"Effect of Synchronous Generator-Based Distributed Generation Resources on Power System Transient Stability Considering Critical Clearing Time Index","authors":"N. Ghasemkhani, R. Khalili, B. Zaker, G. Gharehpetian","doi":"10.1109/EPDC.2018.8536275","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536275","url":null,"abstract":"Due to the increase in demand and expansion of power grid, the role of distributed generations (DGs) is of interest in recent studies. Less environmental issues, less harmful emission, the high cost of centralized generation, and improving power quality indices are some of the lucrative points of DGs which makes them attractive. microgrids and active distribution networks are important topics regarding DGs in distribution networks. Although microgrids and active distribution networks have numerous advantages, they have some shortcomings. The presence of inertia-less or low inertia sources in these networks endangers the stability of the upstream network. The aim of this study is investigating the transient stability of the upstream power network by considering the critical clearing time (CCT) in the presence of synchronous generator-based DGs with different penetration levels. The overall behavior of the network in relation to the three-phase faults at different locations of the upstream network will be studied to examine the transient stability. In order to investigate the results, simulations will be carried out on IEEE 9-bus transmission system as the upstream network and the IEEE 33-bus distribution system as an active distribution network connected to it.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122077636","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Gholami, Ali Abbaspour Tehrani Fard, M. Moeini‐Aghtaie
{"title":"Linear Voltage Based State Estimator for Active Distribution System Including Phasor Measurement Unit (PMU)","authors":"M. Gholami, Ali Abbaspour Tehrani Fard, M. Moeini‐Aghtaie","doi":"10.1109/EPDC.2018.8536296","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536296","url":null,"abstract":"In recent years, vision of distribution networks has been changed from passive to highly complex active network. This change results in some challenges in monitoring, control and protection systems that are based on situation awareness of the network conditions. To address these challenges, distribution state estimation (DSE) is a key element. State estimation in traditional distribution systems are largely based on substation measurements and pseudo-measurements (historical data). However, in active distribution network data from phasor measurement units (PMUs) can be used in a cost-effective manner for accurate system state estimation with significant reporting rate. In this paper, traditional linear voltage based SE algorithm (in rectangular form) has been extended in term of inclusion of PMUs for providing accurate estimation in the active distribution network. To evaluate the performance of the proposed voltage based DSE in the active distribution network, the generic 77 -bus UK distribution network has been simulated in Open DSS software, and its power flow results feed to MATLAB software environment.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117012606","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Half-Bridge Power Quality Conditioner for Railway Traction Distribution System Based on a New Balancing Transformer","authors":"Hossein Mahdinia Roudsari, A. Jalilian, S. Jamali","doi":"10.1109/EPDC.2018.8536270","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536270","url":null,"abstract":"In this paper, a novel configuration for the railway traction substation (TSS) is proposed to mitigate the grid-side PQ indices. In order to overcome the mentioned drawbacks of the conventional traction transformer, a new balanced transformer is designed. The new balanced transformer is utilized in a TSS of electrified railway distribution system together with a half-bridge railway PQ conditioner (HBRPQC) to improve the grid-side power factor, and lower the grid-side total harmonic distortion and most importantly the grid-side NSC and NSV. The proposed configuration reduces the total kVA rating of the HBRPQC compared to the conventional TSS comprised of unbalanced traction transformers. The simulation results are presented to validate the performance of the proposed scheme.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129898343","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Identification of the Best Charging Time of Electric Vehicles in Fast Charging Stations Connected to Smart Grid Based on Q-Learning","authors":"Morteza Rahimi Shaarbaf, M. Ghayeni","doi":"10.1109/EPDC.2018.8536301","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536301","url":null,"abstract":"In this paper, a new method for identifying the best charging hours, proportional to providing discounts on energy sales prices, is suggested by using reinforcement learning techniques at fast charging stations for electric vehicles. Given the ever-increasing power of electric vehicles as an important consumer of smart grids for electric power distribution, charging of these vehicles in smart grids is very important. The waiting time in the queue as well as the owners' profits are two important parameters in design fast charging stations. In previous studies, when the vehicles arrival rate increases to busy hours, the waiting time in the vehicles queue is higher than the driver's satisfaction, causing a number of vehicles to leave the station and reduced the rental profits, but can be Providing discounts on energy sales prices during stand-by hours encourages drivers to charge at these hours. In the proposed method, three important parameters, waiting time in the queue, the amount of energy costs paid by the owners of the vehicles, as well as the profits of the owners of the station, were examined to determine the best hours of charge for vehicles, in proportion to the discounts provided by the owners of the stations. The simulation results show that with the proposed method, the owners of the stations increased by 4 %, and also the drivers would save from 10% to 40% at their own expense, according to the selected ones for charging, and less time in queue stand.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"111 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131258317","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
ValiAllah Naseri, B. Kashanizadeh, Farhad Varposhti
{"title":"Online Operational Budgeting of Electricity Distribution Network Based on Integration Strategic and Operational Planning by Swot & AHP Methods","authors":"ValiAllah Naseri, B. Kashanizadeh, Farhad Varposhti","doi":"10.1109/epdc.2018.8536274","DOIUrl":"https://doi.org/10.1109/epdc.2018.8536274","url":null,"abstract":"Regarding the priority of economic resistance programs for economic efficiency in the iran country's program and budget, operational budgeting is considered as an essential tool for achieving the objectives of the upstream documents of the country's strategic plan. In this paper, the online budgeting of the electricity distribution network based on the strategic and operational integration plan by SWOT method and the analysis hierarchical process (AHP), studied in Tehran Electric Power Distribution Company. The results of the new indicators are based on the strategic plan of the company based on the analysis of strengths, weaknesses, threats and opportunities based on the external and internal factors of SWOT. Also, how to weigh these indicators, The Integrated Management Information System (MIS) which are online from database is developed to improve the operational efficiency of the company through the AHP method. Outputs from the case study The proposed new operational budgeting has been added in comparison with conventional approaches.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"445 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124258020","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ali Arjomandi-Nezhad, M. Fotuhi‐Firuzabad, Hesam Mazaheri, M. Moeini‐Aghtaie
{"title":"Developing a MILP Method for Distribution System Reconfiguration After Natural Disasters","authors":"Ali Arjomandi-Nezhad, M. Fotuhi‐Firuzabad, Hesam Mazaheri, M. Moeini‐Aghtaie","doi":"10.1109/EPDC.2018.8536297","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536297","url":null,"abstract":"High consequence low probability (HCLP) events cause many interruptions in distribution systems. Reconfiguration is an efficient tool in distribution system restoration after natural disasters. This paper presents a novel method for distribution system reconfiguration taking into account loads restoration by means of switches and distribution generations (DGs) scheduling. In this method, configurations that contain more grid-connected buses, less islands and serve maximum amount of loads are preferred. To reach this goal, summation of restored load, number of grid connected bus and number of closed lines are maximized. The associated optimization problem is modeled as a mixed-integer linear programming (MILP) model; furthermore, presented framework is studied on IEEE 34-bus test network to verify its efficiency.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130115303","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mehran Hajiaghapour‐Moghimi, A. Moradnouri, M. Vakilian
{"title":"Feasibility of Amorphous Symmetric Core Transformer Under Distribution Network Planning","authors":"Mehran Hajiaghapour‐Moghimi, A. Moradnouri, M. Vakilian","doi":"10.1109/EPDC.2018.8536288","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536288","url":null,"abstract":"Employing efficient distribution transformers under distribution network planning, significant amounts of energy and expenses can be saved. In this paper the multiple design algorithm has been used for design of high efficiency 3D-wound core transformers. Amorphous and silicon steel used as ferromagnetic core materials in the design process of this work. Then an optimal transformer sizing (OTS) algorithm is implemented into optimal selection of transformer, through two case studies. A sample distribution transformer of AB’ energy efficiency class with a conventional type of core is designed and compared with the amorphous and silicon steel 3D-wound core transformers, respectively. The corresponding results showed that amorphous 3D-wound core transformers are the best choice under a long-term planning process, even in Iran where the electricity price rate is very low, i.e. with an average rate of 2.0 cents/kW.","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130488644","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Novel Strategy for Providing Visibility of Distributed Generators (DGs) in Dispatching Centers","authors":"A. Tashk, H. Omidi","doi":"10.1109/EPDC.2018.8536283","DOIUrl":"https://doi.org/10.1109/EPDC.2018.8536283","url":null,"abstract":"In recent years, employment of dispatching systems including SCADA in Iranian Regional Electric Companies for automation of power plants, sites and generators has become common and outspread. Such systems comprise of some specific equipments such as remote terminal unit (RTU), communication medium and computerized dispatching center. For connecting RTU to computer center, different telecommunication media are employed. These media can be power line carrier (PLC), fiber optic and other conventional communication methods. In some cases, there is no way to employ the named communication methods due to unavailability of essential media. In such cases, it is necessary that a new communication strategy be established. In this paper, two new strategies for providing possible data transmission are proposed. For the first solution, a two-way communication over serial to Ethernet conversion base on static IP is proposed. In the first strategy, the communication is provided through asynchronous digital subscriber line (ADSL) modem. The second strategy is proposed for data exchanging between distributed generators (DGs) and upstream electric power stations. The acquired and collected data are transmitted to dispatching center. The proposed telecommunication strategies are implemented practically with success and acceptable performance for DGs under supervision of Fars regional electric company (FREC).","PeriodicalId":127967,"journal":{"name":"2018 Electrical Power Distribution Conference (EPDC)","volume":"944 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127006848","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}