The 4th 2011 Biomedical Engineering International Conference最新文献

筛选
英文 中文
Driver fatigue monitoring system using video face images & physiological information 利用视频人脸图像和生理信息的驾驶员疲劳监测系统
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172034
S. Anumas, Soo-chan Kim
{"title":"Driver fatigue monitoring system using video face images & physiological information","authors":"S. Anumas, Soo-chan Kim","doi":"10.1109/BMEICON.2012.6172034","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172034","url":null,"abstract":"This paper is focused on driving impairment, due to fatigue of a driver. Both face features and physiological signal were used to monitor the fatigue. Analyzing the images from the video, we applied Active Shape Models (ASM) algorithm to get the changes on the face, such as degrees of eye closure, eye closure duration, blink frequency, degrees of mount opening, yawn duration. We analyzed Heart Rate Variability to evaluate the driver's level of fatigue using photoplethysmography signal. These parameters were combined using a fuzzy classifier to infer the level of driver fatigue. The system has been tested with different environment both night and day by simulation in the laboratory and with different users.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115993546","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Development of electric field sensing system as a putative skin sensation sensor 电场传感系统作为一种假定的皮肤感觉传感器的发展
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172015
S. Suzuki, Y. Saegusa, T. Takahashi
{"title":"Development of electric field sensing system as a putative skin sensation sensor","authors":"S. Suzuki, Y. Saegusa, T. Takahashi","doi":"10.1109/BMEICON.2012.6172015","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172015","url":null,"abstract":"Some kinds of animals, such as sharks or catfish, has extra ordinary skin sensation system, mediated by electric field in aqueous solution. Such a sensation of animal is used for detection of pray creatures in water of low visibility. Mimicking this kind of detection mechanism, we developed a sensing system, mediated by electric field in aqueous gel. A contact detection system with a gel layer and electrodes was constructed and characteristics of the system was measured quantitatively.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123020840","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Experimental study of digital microfluidic biochip 数字微流控生物芯片的实验研究
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172053
K. Ugsornrat, T. Pogfai, T. Maturos, A. Wisitsoraat, A. Tuantranont
{"title":"Experimental study of digital microfluidic biochip","authors":"K. Ugsornrat, T. Pogfai, T. Maturos, A. Wisitsoraat, A. Tuantranont","doi":"10.1109/BMEICON.2012.6172053","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172053","url":null,"abstract":"Digital microfluidic biochip was fabricated with a single-plate EWOD device. The EWOD microfluidic system consists of 1.4 mm wide, 10 mm long. An enzyme and DNA was driven by moving droplet through each electrode (dimension of 2 mm width and 2 mm long) that control by digital operation. The digital microfluidic biochip has been successfully designed fabricated and tested. The fundamental fluidic operation (transporting and merging) were studied by controlling the wetting property of the droplet surface through electric potential, which can be used for lab-on-a-chip or micro total analysis system (μTAS). The tested results confirm that ionized droplet can be transported with fully controlled manner by applying voltage less than 60 V. Moreover, the droplet can be merged by applied voltage to generate digital signal for two control electrodes at the same condition.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"57 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123385299","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Counting number of sweat glands using image processing 利用图像处理计算汗腺数量
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172039
N. Pakkaselevat, S. Kiattisin, W. Wongseree, A. Leelasantitham
{"title":"Counting number of sweat glands using image processing","authors":"N. Pakkaselevat, S. Kiattisin, W. Wongseree, A. Leelasantitham","doi":"10.1109/BMEICON.2012.6172039","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172039","url":null,"abstract":"This paper presents counting number of the sweat glands using image processing. This method uses a process of image processing as follows. The cropped image of the sweat glands is resized for an extensive size and it is converted to gray image. Then, unsharp filter is used for this image to adjust clearly the sweat glands. Quality of the image will be improved for image enhancement using adaptive histogram equalization. Finally, extended minima transform, i.e. the regional minima of the H-minima transform, is used for counting number of the sweat glands. The experimental results show that the accuracy, sensitivity and precision are approximately at 70.31%, 77.38% and 88.89%, respectively. It saves time to analysis of the sweat glands.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114170659","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Alphabet matrix layout in P300 speller may alter its performance P300拼字器中的字母矩阵布局可能会改变其性能
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172025
Y. Sakai, T. Yagi
{"title":"Alphabet matrix layout in P300 speller may alter its performance","authors":"Y. Sakai, T. Yagi","doi":"10.1109/BMEICON.2012.6172025","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172025","url":null,"abstract":"The P300 speller is one of the brain-computer interfaces that uses the P300 event-related potential. The performance of the P300 speller is influenced by various parameters related to the matrix displayed. In addition, it is reported that letters in the corner or at the edge of the matrix can be concentrated on more easily, giving a higher accuracy rate for the P300 speller. In order to improve the performance of the P300 speller, we have focused on an alphabet layout on the matrix and evaluated P300 amplitude and system output in terms of inter-character distance. Experimental results revealed that the shorter the inter-character distance, the larger the P300 amplitude. However, this did not lead to better system performance. The results suggest that a classifier in the system should be improved to make good use of the characteristics of P300 amplitude observed in the experiment.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126449266","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Stability characteristics of patellofemoral prostheses: An in-vitro pilot study 髌股假体的稳定性特征:一项体外试点研究
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172063
W. Senavongse
{"title":"Stability characteristics of patellofemoral prostheses: An in-vitro pilot study","authors":"W. Senavongse","doi":"10.1109/BMEICON.2012.6172063","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172063","url":null,"abstract":"The patellofemoral joint prosthesis has been a topic of interest comparing to total knee joint replacements. In recent years, there have been more interests in the development of unicompartmental prostheses which is in line with minimally-invasive surgery used in modern days. Therefore, this research presents an in-vitro pilot study in the area of patellofemoral stability characteristics of unicompartmental prosthesis comparing to normal knees. The findings from this research show promising results which will give rise to more researches and interests in developing better unicompartmental knee prosthesis.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"27 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125683756","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
How to make an easy human thorax model 如何制作一个简单的人体胸腔模型
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172047
C. Thaijiam
{"title":"How to make an easy human thorax model","authors":"C. Thaijiam","doi":"10.1109/BMEICON.2012.6172047","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172047","url":null,"abstract":"Physical computer models are important in order to investigate simulation results. This paper presents how to make an easy human thorax model, combining a whole heart, left and right lungs, and a chest. Geometric approximation algorithms were employed to model the human thorax from raw geometric data. This human thorax model was constructed using commercial software. Results showed a whole human thorax model.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130987233","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A design of configurable ECG recorder module 一种可配置心电记录仪模块的设计
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172020
A. Punapung, S. Tretriluxana, K. Chitsakul
{"title":"A design of configurable ECG recorder module","authors":"A. Punapung, S. Tretriluxana, K. Chitsakul","doi":"10.1109/BMEICON.2012.6172020","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172020","url":null,"abstract":"A modular design of Electrocardiogram (ECG) acquisition system is presented. As a crucial part of the system, the Front-End module is made of a programmable, mixed-signal Application Specific Integrated Circuit (ASIC). This module is designed to satisfy the various forms of bioelectrical measurement with no hardware modification. Controlled by a 32-bit microcontroller, the prototype module recorded the simulated signal in two different standard ECG recording configurations, ten and six electrodes placements. Our study shows a good performance signal recording and the module is open to further developed.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114470928","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Sensor pillow system: Monitoring cardio-respiratory and posture movements during sleep 传感器枕头系统:监测睡眠时的心肺和姿势运动
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172021
S. Lokavee, N. Watthanawisuth, J. Mensing, T. Kerdcharoen
{"title":"Sensor pillow system: Monitoring cardio-respiratory and posture movements during sleep","authors":"S. Lokavee, N. Watthanawisuth, J. Mensing, T. Kerdcharoen","doi":"10.1109/BMEICON.2012.6172021","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172021","url":null,"abstract":"In this paper, we have developed a sleep monitoring and gesture recognition system for patient based on polysomnography which will be useful for patient communication with healthcare personals and/or relatives. In particular, we present the sensor pillow system that employs wireless networks based on low-cost ZigBee technology and a sensor array of force sensitive resistors (FSR) based on polymer thick film (PTF) device for classifying and recognizing sleep posture. This paper also proposes a simple motion model that explains the change of the head pressure distribution. In addition, we can detect some physiological parameters during the sleep stages and wakefulness as well as record cardio-respiratory activity as related to different physiological factors. The integration of the sensor system and wireless technology with a computer software could make this healthcare monitoring system a commercial product valuable for point-of-care applications.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121989905","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Investigation of the ion concentration effect on Eucalyptus root growth in a.c. electric field 交流电场条件下离子浓度对桉树根系生长影响的研究
The 4th 2011 Biomedical Engineering International Conference Pub Date : 2012-03-22 DOI: 10.1109/BMEICON.2012.6172018
T. Hotta, S. Suzuki, T. Takahashi
{"title":"Investigation of the ion concentration effect on Eucalyptus root growth in a.c. electric field","authors":"T. Hotta, S. Suzuki, T. Takahashi","doi":"10.1109/BMEICON.2012.6172018","DOIUrl":"https://doi.org/10.1109/BMEICON.2012.6172018","url":null,"abstract":"Electric stimulation of animal tissues, such as nerve fiber or muscle, has prominent effects of strong sensation or contraction of limbs. On the other hand, electric stimulation of plants has been reported to have rather depressing effects on plant growth. It seems to be caused by damages of cells by the electric stimulation. However some plant species showed increased growth rate by application of a.c. electric field in specific field intensity range. In this study, root growth enhancement of Eucalyptus seedling by electric field stimulation was precisely investigated. Especially the effects of soluble factors in culture medium, to the growth rate of Eucalyptus seedling in water, was measured. Eucalyptus seedlings were cultured in diluted M.S. medium. The seedlings in a vessel was exposed to 50 [Hz] a.c. electric field of 0 to 100 [V/m]. In some cases, the seedlings showed enhanced growth rate in 40-60 [V/m], but in some cases, however, growth rate was enhanced in higher intensities. These discrepancy may come from the large growth rate diversity of seedlings in a culture. Ion concentration of medium was investigated by measuring the electric conductivity. Within some 10 [mS/cm] fluctuation, ion concentration showed no specific effects on growth rate. To eliminate the effect of other unknown bioactive factors, culture system with medium circulation is utilized and field effects was measured. From the results, involvement of H+ ion in root growth control was expected, which suggests homologous system with nerve stimulation of animal in plant growth control.","PeriodicalId":122776,"journal":{"name":"The 4th 2011 Biomedical Engineering International Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132401634","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书