{"title":"2-D Branching Components Array with Distributed-Index Planar Microlens","authors":"M. Oikawa, K. Iga, S. Misawa","doi":"10.1364/giois.1984.thed3","DOIUrl":"https://doi.org/10.1364/giois.1984.thed3","url":null,"abstract":"Optical fiber communication and electro-optic systems require wide variety of mass-producible lightwave components. However, the fact that conventional micro-optics or even guided-wave planar components need high precision optical alignment prevents us from easy production. In order to avoid this difficulty we proposed stacked planar optics1, where 2-D planar microlens array and optical components are integrated to form 2-D integrated lightwave components. In this paper we present perfomances of improved microlens array and its application to 2-D arrayed branching components.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130560466","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement of Numerical Aperture of Planar Microlens by Far Field Pattern Method","authors":"S. Misawa, M. Oikawa, K. Iga","doi":"10.1364/giois.1984.thed4","DOIUrl":"https://doi.org/10.1364/giois.1984.thed4","url":null,"abstract":"The measurement of the Numerical Aperture (N.A.) of a distributed index (DI) planar microlens1) is important for its evaluation of focusing power. There have been some methods of measuring the N.A. of conventional lenses, e.g., the ratio of aperture diameter and focal length is easily determined and sometimes, the Apertmeter2) has been utilized. The planar microlens, on the other hand, has some situations different from conventional spherical lens; i.e., the size of its diameter is smaller than 1 mm and the focal length is 1.5 mm~2 mm. Moreover, the physical edge of DI microlens does not necessarily indicate the effective lens size, if the index distribution near the periphery does not suitably contribute to focusing. We must, therefore, introduce some new method for measuring N.A. of planar microlens.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126458622","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Fuhs, Herbert M. Carr, O. Amichai, James M. Terrell
{"title":"Spike Gradient Refractive Index Missile Seeker Lens","authors":"A. Fuhs, Herbert M. Carr, O. Amichai, James M. Terrell","doi":"10.1364/giois.1984.thea4","DOIUrl":"https://doi.org/10.1364/giois.1984.thea4","url":null,"abstract":"A missile design problem which has evaded solution for a long time is the conflict in shape of the seeker lens. For efficient aerodynamics (i.e. low drag) a sharp conical or ogival shape is designed; for good optics, a hemispherical shape is best. A spike lens has poor optical performance, and a blunt lens has very large wave drag at supersonic speeds.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116194073","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An Imaging Device Using a Micro Roof Mirror Lens Array and Its Imaging Properties","authors":"M. Kawazu, T. Inokuchi","doi":"10.1364/giois.1984.thee3","DOIUrl":"https://doi.org/10.1364/giois.1984.thee3","url":null,"abstract":"The gradient index rod lens array (1) and the strip lens (2) have been developed as unit magnification imaging devices. These devices are used widely in copiers and like systems.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"28 33","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120836080","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design of Medical Endoscopes Using GRIN Optics","authors":"D. Leiner","doi":"10.1364/giois.1984.feb1","DOIUrl":"https://doi.org/10.1364/giois.1984.feb1","url":null,"abstract":"Rigid endoscopes are widely used instruments for least invasive surgery of various parts of the body, including the abdomen, urinary system, and knee. The rigid endoscope should be distinguished from the flexible fiberoptic endoscope which is generally of larger diameter and is comprised of a two-dimensional array of closely-packed optical fibers. Medical endoscopes using GRIN optics are always rigid endoscopes. The diameter of rigid endoscopes generally range between 1.7mm and 5mm. A typical rigid endoscope may contain up to 50 spherical surfaces. Because of the difficulty in fabricating very small lenses, gradient-index lenses are preferred for the smaller diameter endoscopes.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125446455","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Raytracing through decentered and tilted graded-index optical systems.","authors":"Anurag Sharma, M. Jeyaprakash, A. Ghatak","doi":"10.1364/giois.1984.thec2","DOIUrl":"https://doi.org/10.1364/giois.1984.thec2","url":null,"abstract":"We had earlier reported a method1 for tracing finite rays through graded index media and had shown that for a given accuracy our method is faster than existing methods. In this paper we extend this method to trace rays through decentered and tilted graded-index optical systems. In existing literature on this subject, the shift of the centre and the till of a component have generally been taken in the same plane2. Using our method, we consider general cases of tilt and decentering and discuss the effect of these defects on various total aberrations. In particular, we discuss the effect of decentering and tilts of surfaces and gradient on the imaging properties of photographic singlet designs reported by Marchand3.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132661194","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ray Tracing In Inhomogenous Media1","authors":"M. Rimmer","doi":"10.1364/giois.1984.thec1","DOIUrl":"https://doi.org/10.1364/giois.1984.thec1","url":null,"abstract":"Gradient index materials, in which the index of refraction varies as a function of position, are being used commercially in high volume.2,3 Thus, the ability to easily evaluate systems using such materials is becoming more important. Since the ray paths are typically curved trajectories, ray tracing is more complicated than for homogeneous materials.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128707149","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Monte Carlo study of the dependence of the image quality of a Wood lens on refractive index profile fluctuations and mounting errors","authors":"A. Boardman, D. Horncastle","doi":"10.1364/giois.1984.fea5","DOIUrl":"https://doi.org/10.1364/giois.1984.fea5","url":null,"abstract":"Minimum aberration optical systems can be designed by trading off the adjustable parameters against each other. Some of these parameters are intrinsic and may relate, in the case of gradient index lenses, to the refractive index profile while others may be mechanical in origin, relating, for example, to the degree of tilt and decentration the optical system can tolerate.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114594487","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Grating Lenses for Optical Components","authors":"G. Hatakoshi, K. Goto","doi":"10.1364/giois.1984.thee1","DOIUrl":"https://doi.org/10.1364/giois.1984.thee1","url":null,"abstract":"Grating lenses will have wide applications in optical communication and optical information processing. Utilizing their focusing, imaging and Fourier transforming functions, they are applied, for example, to couplers for fiber optics1,2), optical heads in optical disk systems3), X-ray imaging elements4) and Fourier transforming lenses for optical processors5). Applications to waveguide devices6-8) are also reported.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128120932","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Gradient Index Lenses Made by Porous Glass Process","authors":"Y. Asahara, S. Ohmi","doi":"10.1364/giois.1984.theb1","DOIUrl":"https://doi.org/10.1364/giois.1984.theb1","url":null,"abstract":"Recently there has been interest in the development of processes for fabricating gradient index (GRIN) lenses, the profile of which is expressed by Here, n0 is the index on the center axis, r is the distance from the center axis and g is the focusing factor. New process, termed \"molecular stuffing process\" was currently developed for fabricating radially distributed index profiles.[1,2]. This process offers a possibility of making large sized lenses, but there have been no accurate measurements and analyses of their index profiles and aberration characteristics. The purpose of this study is to find the optimum fabrication conditions for parabolic profiles and to evaluate the optical characteristics of lenses made by the molecular stuffing technique.","PeriodicalId":122604,"journal":{"name":"Fourth Topical Meeting on Gradient-Index Optical Imaging Systems","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134016755","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}