Eye & Contact Lens: Science & Clinical Practice最新文献

筛选
英文 中文
Thank You to Our 2018 Reviewers. 感谢我们2018年的评审员。
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2019-03-01 DOI: 10.1097/ICL.0000000000000588
P. Asbell
{"title":"Thank You to Our 2018 Reviewers.","authors":"P. Asbell","doi":"10.1097/ICL.0000000000000588","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000588","url":null,"abstract":"","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"275 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73381454","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Absorption and Extraction of Inflammatory Mediators From Contact Lens Materials. 隐形眼镜材料中炎症介质的吸收与提取。
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2019-01-29 DOI: 10.1097/ICL.0000000000000576
Cecilia Chao, K. Richdale, M. Willcox
{"title":"Absorption and Extraction of Inflammatory Mediators From Contact Lens Materials.","authors":"Cecilia Chao, K. Richdale, M. Willcox","doi":"10.1097/ICL.0000000000000576","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000576","url":null,"abstract":"OBJECTIVES\u0000This report aimed to explore whether certain inflammatory mediators were absorbed, extracted, or bound by various contact lens materials.\u0000\u0000\u0000METHODS\u0000Comfilcon A, balafilcon A, omafilcon A, and etafilcon A were soaked in 500 and 100 pg/mL of interleukin-8 (IL-8), matrix metalloproteinase-9 (MMP-9), or interleukin-1 receptor antagonist (IL-1Ra), and also in combined solutions of inflammatory mediators (500 pg/mL or 100 pg/mL) separately. Lenses were then extracted in 1:1 2% trifluoroacetic acid:acetonitrile. The extracted and residual concentrations of inflammatory mediators were determined using enzyme-linked immunosorbent assays. Absorbed (control-residual) and firmly bound (absorbed-extracted) concentrations were calculated for analysis.\u0000\u0000\u0000RESULTS\u0000More MMP-9 was absorbed by omafilcon A (466±9 pg/mL) than balafilcon A (P=0.006; 437±11 pg/mL) or etafilcon A (P=0.001; 428±13 pg/mL) when soaked in 500 pg/mL, but no differences in 100 pg/mL. More MMP-9 remained firmly bound to omafilcon A (P=0.03; 174±3 pg/mL), comfilcon A (P=0.049; 168±34 pg/mL), and balafilcon A (P=0.01; 186±14 pg/mL) than etafilcon A (128±22 pg/mL). There were no differences in IL-8 absorption between lenses; however, more IL-8 remained firmly bound to omafilcon A (P=0.01; 336±25 pg/mL) than etafilcon A (106±133 pg/mL) when soaked in 500 pg/mL. No differences were found in concentrations of absorbed or firmly bound IL-1Ra between materials. When the mediators were combined, IL-8 was absorbed more in etafilcon A (P=0.03) than in other lens materials, but the absorbed IL-8 did not remain firmly bound.\u0000\u0000\u0000CONCLUSIONS\u0000The uptake and extraction of inflammatory mediators from contact lenses was affected by competitive binding between the mediators.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"11 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86962799","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
The Effect of Ocular Demodex Colonization on Schirmer test and OSDI Scores in Newly Diagnosed Dry Eye Patients. 新诊断干眼症患者眼蠕形螨定殖对Schirmer试验和OSDI评分的影响。
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2019-01-01 DOI: 10.1097/ICL.0000000000000640
T. Ayyildiz, F. Sezgin
{"title":"The Effect of Ocular Demodex Colonization on Schirmer test and OSDI Scores in Newly Diagnosed Dry Eye Patients.","authors":"T. Ayyildiz, F. Sezgin","doi":"10.1097/ICL.0000000000000640","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000640","url":null,"abstract":"OBJECTIVE To determine whether ocular Demodex colonization results in differences in Schirmer test scores and Ocular Surface Disease Index (OSDI) questionnaire values in individuals with dry eye disease (DED) diagnosed for the first time. METHOD Eighty-eight adults aged 40 to 68 years who were admitted to Ophthalmology outpatient clinic for routine ophthalmological examination or presbyopia examination and diagnosed with DED for the first time and who do not have any chronic disease were included in the study. All the patients were asked to complete the OSDI, which is widely used for assessing dry eye symptom severity and vision-related functioning. The Schirmer test was performed, and then two eyelashes were taken from the inferior eyelids of each eyes. After saline (0.09% NaCl) was added to the sample, it was quickly taken to the microbiology laboratory, which is located next to the Ophthalmology policlinic. The sample was evaluated by a parasitologist experienced in Demodex. RESULTS One hundred sixty-eight eyes of 84 patients were included in the study. Average Schirmer test score was 2.1±0.5, the OSDI questionnaire score was 61.82±10.95, and the mean age was 55.36±8.74 years in patients who had Demodex colonization (n=30), whereas the average Schirmer test score was 6.6±0.9 score, OSDI questionnaire score was 40.96±12.73, and the mean age was 49.12±6.87 years in patients without Demodex colonization (n=58). It has been observed that dry eye patients with Demodex colonization had a higher mean age (P: 0.001), higher mean OSDI score (P: 0.001), and lower average Schirmer test score (P: 0.001) compared with those without Demodex. The significant relationship between lower Schirmer test score and higher OSDI rates and occurrence of Demodex infestation continued after adjusting for mean age values (P=0.012; P=0.035). CONCLUSION It was determined that the presence of ocular Demodex colonization was associated with the average Schirmer test scores, OSDI scores, and age values in patients with newly diagnosed DED. Demodex quantity was found increased in older aged patients, but the significant relationship between lower Schirmer test score and higher OSDI rates and Demodex infestation persisted even after controlling the mean age values. Supporting these findings with large-numbered and randomized-controlled studies will help in clarifying the association of the Demodex infestation with etiopathogenesis of dry eye.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"24 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83210656","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
Efficacy and Safety of OTX-101, a Novel Nanomicellar Formulation of Cyclosporine A, for the Treatment of Keratoconjunctivitis Sicca: Pooled Analysis of a Phase 2b/3 and Phase 3 Study. 新型环孢素a纳米胶束制剂OTX-101治疗Sicca角膜结膜炎的疗效和安全性:2b/3期和3期研究的汇总分析
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2019-01-01 DOI: 10.1097/ICL.0000000000000636
J. Sheppard, Shane R. Kannarr, J. Luchs, R. Malhotra, A. Justice, A. Ogundele, Charles Darby, J. Bacharach
{"title":"Efficacy and Safety of OTX-101, a Novel Nanomicellar Formulation of Cyclosporine A, for the Treatment of Keratoconjunctivitis Sicca: Pooled Analysis of a Phase 2b/3 and Phase 3 Study.","authors":"J. Sheppard, Shane R. Kannarr, J. Luchs, R. Malhotra, A. Justice, A. Ogundele, Charles Darby, J. Bacharach","doi":"10.1097/ICL.0000000000000636","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000636","url":null,"abstract":"BACKGROUND OTX-101 (CEQUA™) is approved in the United States for treatment of keratoconjunctivitis sicca (KCS). This pooled analysis of 2 studies (phase 2b/3 and phase 3) evaluates the efficacy and safety of OTX-101 0.09% in the intent-to-treat (ITT) population and the subgroup of patients with a baseline Schirmer score less than 10 mm. METHODS In these randomized, multicenter, double-masked, vehicle-controlled studies, patients received 1 drop of either OTX-101 or vehicle in both eyes twice daily. A Schirmer's test was performed at baseline and day 84/early discontinuation. Symptom Assessment iN Dry Eye (SANDE) scores and adverse events were monitored at each visit. RESULTS The pooled analysis included 523 and 525 patients randomized to OTX-101 0.09% and vehicle, respectively. In the ITT population, 16.6% of eyes receiving OTX-101 and 9.0% of eyes receiving vehicle showed a day 84 increase in Schirmer score ≥10 mm from baseline (P<0.0001). In the subgroup with Schirmer score less than 10 mm at baseline, 18.7% and 10.2% of eyes receiving OTX-101 and vehicle, respectively, exhibited this outcome (P=0.0001). The mean (SD) percent change from baseline in global SANDE scores on day 84 in the ITT population was -29.0% (39.0%) and -30.4% (39.5%) for OTX-101 and vehicle groups, respectively. In the subgroup, the mean (SD) percent change was -27.3% (39.7%) and -31.4% (38.3%) for OTX-101 and vehicle groups, respectively. Adverse events were mostly mild to moderate. CONCLUSIONS OTX-101 improved tear production compared with vehicle. Both OTX-101 and vehicle showed improved SANDE scores over baseline. OTX-101 was well tolerated in patients with KCS.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"123 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85613522","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
The Presence of Conjunctivochalasis in Obstructive Sleep Apnea Patients 阻塞性睡眠呼吸暂停患者结膜松弛的存在
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2018-09-01 DOI: 10.1097/ICL.0000000000000361
M. Acar, H. Fırat, Melike Yüceege, Aysun Sanal Dogan, S. Çalışkan, C. Gürdal
{"title":"The Presence of Conjunctivochalasis in Obstructive Sleep Apnea Patients","authors":"M. Acar, H. Fırat, Melike Yüceege, Aysun Sanal Dogan, S. Çalışkan, C. Gürdal","doi":"10.1097/ICL.0000000000000361","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000361","url":null,"abstract":"Objectives: The aim of our study was to detect the presence of conjunctivochalasis (CCh) in obstructive sleep apnea (OSA) patients. Methods: We included 54 subjects (41 OSA patients and 14 control subjects) in the study. All the patients were assessed regarding the presence and stage of CCh. Results: The patients were grouped according to their apnea-hypopnea index as determined during nocturnal polysomnography in our laboratory as mild (12 patients), moderate (16 patients), and severe (13 patients) OSA. The CCh rate was 87.8% in the OSA group and 57.1% in the control group (P=0.022). Mean CCh stage was 1.58±1.24, 2.38±0.88, and 2.15±0.98 in the mild, moderate, and severe OSA groups, respectively, and 0.71±0.72 in the control group (P=0.0001). Conclusions: The moderate and severe OSA groups were associated with higher rates and more advanced stages of CCh. We believe that detailed conjunctival assessment is necessary for patients with complaints such as burning, stinging, and foreign body sensation, which we frequently confront in daily practice. In particular, young patients diagnosed with CCh must be carefully assessed regarding sleep apnea. In light of the above findings, we suggest that patients with ocular surface symptoms that are not relieved by topical medical treatment should be assessed for CCh and OSA. Longitudinal studies monitoring the response of CCh to OSA treatment are needed to clarify the relationship between CCh and OSA.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"50 1","pages":"S163–S166"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83181052","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
The Characteristics of Excimer Laser Refractive Surgery Candidates 准分子激光屈光手术候选者的特点
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2018-09-01 DOI: 10.1097/ICL.0000000000000360
H. Hashemi, M. Khabazkhoob, R. Pakzad, A. Yekta, M. Nojomi, Payam Nabovati
{"title":"The Characteristics of Excimer Laser Refractive Surgery Candidates","authors":"H. Hashemi, M. Khabazkhoob, R. Pakzad, A. Yekta, M. Nojomi, Payam Nabovati","doi":"10.1097/ICL.0000000000000360","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000360","url":null,"abstract":"Purpose: To determine the demographic and refractive characteristics of excimer laser refractive surgery candidates in Iran. Methods: This was a cross-sectional study between 2010 and 2014. All information was collected from 28 centers randomly selected from 12 provinces. Then, for each season of the year, one week was chosen through simple random selection, and within each week, 3 days were again chosen randomly. All excimer laser surgical procedures performed during these 3 days were identified by training staff, and data were extracted from patient charts. Results: A total of 14,569 charts were reviewed; 67.5% of the subjects were female and the rest were male. Of the total surgeries, 18.6% had been done in 2010 which reached to 19.1% in 2014. The mean age of people receiving refractive surgery showed an upward trend (P<0.001) and female patients were significantly younger than male patients (P<0.001). The 25 to 39 years age group received the highest number of surgeries (31.9% of the total) and there was a significant association with gender (P<0.001). The most common refractive error was compound myopic astigmatism with a prevalence of 79.3%. In 2010, 33.3% of the performed surgeries were covered by insurance policies, and this decreased to 30.2% in 2014 (P<0.001). Conclusion: Women with compound myopic astigmatism in the age range of 25 and 35 years are the most frequent users of excimer laser refractive surgery. Less than one-third of laser refractive surgeries are covered by insurance policies. Therefore, proper planning for improving services to this group must be given priority.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"4 1","pages":"S158–S162"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79507150","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
The Association of Dry Eye Symptom Severity and Comorbid Insomnia in US Veterans 美国退伍军人干眼症状严重程度与合并症失眠的关系
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2018-09-01 DOI: 10.1097/ICL.0000000000000349
A. Galor, Benjamin Seiden, Jasmine J. Park, W. Feuer, Allison L. McClellan, Elizabeth R. Felix, R. Levitt, C. Sarantopoulos, D M Wallace
{"title":"The Association of Dry Eye Symptom Severity and Comorbid Insomnia in US Veterans","authors":"A. Galor, Benjamin Seiden, Jasmine J. Park, W. Feuer, Allison L. McClellan, Elizabeth R. Felix, R. Levitt, C. Sarantopoulos, D M Wallace","doi":"10.1097/ICL.0000000000000349","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000349","url":null,"abstract":"Purpose: To investigate the association between dry eye (DE) and insomnia symptom severity. Methods: Cross-sectional study of 187 individuals seen in the Miami Veterans Affairs eye clinic. An evaluation was performed consisting of questionnaires regarding insomnia (insomnia severity index [ISI]) and DE symptoms, including ocular pain, followed by a comprehensive ocular surface examination. Using a two-step cluster analysis based on intensity ratings of ocular pain, the patient population was divided into two groups (high and low ocular pain groups: HOP and LOP). A control group was ascertained at the same time from the same clinic as defined by no symptoms of DE (Dry Eye Questionnaire 5 [DEQ5], <6). The main outcome measure was the frequency of moderate or greater insomnia in the DE groups. Results: The mean age of the study sample was 63 years, and 93% were male. All insomnia complaints were rated higher in the HOP group compared with the LOP and control groups (P<0.0005). Most (61%) individuals in the HOP group experienced insomnia of at least moderate severity (ISI≥15) compared with the LOP (41%) and control groups (18%) (P<0.0005). Black race (odds ratio [OR], 2.7; 95% confidence interval [CI], 1.2–6.0; P=0.02), depression severity (OR, 1.2; 95% CI, 1.1–1.3; P<0.0005), and DE symptom severity (DEQ5; OR, 1.1; 95% CI, 1.01–1.2; P=0.03) were significantly associated with clinical insomnia (ISI≥15) after controlling for potential confounders. Conclusions: After adjusting for demographics and medical comorbidities, we show that DE symptom severity is positively associated with insomnia severity.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"31 1","pages":"S118–S124"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81081737","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 35
Comparison of Hospital Cornea Retrieval and Voluntary Eye Donation Program in Eye Banking 眼库中医院角膜摘取与自愿捐赠方案的比较
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2018-09-01 DOI: 10.1097/ICL.0000000000000320
N. Sharma, N. Agrawal, P. Maharana, T. Agarwal, M. Vanathi, R. Vajpayee
{"title":"Comparison of Hospital Cornea Retrieval and Voluntary Eye Donation Program in Eye Banking","authors":"N. Sharma, N. Agrawal, P. Maharana, T. Agarwal, M. Vanathi, R. Vajpayee","doi":"10.1097/ICL.0000000000000320","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000320","url":null,"abstract":"Objectives: Comparison of demographic, clinical, microbiological, and utility profile of the corneas obtained through hospital corneal retrieval program (HCRP) and voluntary eye donation (VED) program. Methods: Donor corneas retrieved during a 14 months period at National eye bank, India were included in the study. The donor cornea grading was done according to the cornea donor study. The corneal swabs were taken from the donor eyes and were sent for microbiological evaluation. The quality of the donor corneas and their utility was assessed. Results: Out of 1,014 donor corneas collected (700 through HCRP, 314 through VED), 455 were of optical grade (91.2% [415/455] through the HCRP and 8.7% [40/455] through the VED). HCRP had a higher proportion of donors in younger age (81.6% vs. 21%, P<0.0001), clear lens (78.6% vs. 66.2%, P<0.0001), and endothelial cell counts of more than2,000 cells per squared millimeter (64.9% vs. 28%, P<0.0001). Higher proportions of corneas in HCRP were used for optical indications (Penetrating keratoplasty, 24.5% vs. 13.3%, P<0.0001 and endothelial keratoplasty, 18.14% vs. 4.14%, P<0.0001). VED had a greater number of corneas found unsuitable for keratoplasty (37.4% vs. 6.4%, P<0.001). Most of the donors in the HCRP belonged to lower socioeconomic status (59.4% vs. 17.9%, P<0.0001). No significant difference was found in the microbial contamination between the two groups. Conclusions: Most corneas retrieved through HCRP were of optical grade quality and efforts should be focused on HCRP to reduce the demand-supply deficit in cornea transplantation.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"99 1","pages":"S54–S58"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81079330","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Combined Effect of Ocular and Multifocal Contact Lens Induced Aberrations on Visual Performance: Center-Distance Versus Center-Near Design 眼和多焦隐形眼镜引起的像差对视觉表现的综合影响:中心距离与中心近距离设计
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2018-09-01 DOI: 10.1097/ICL.0000000000000355
D. Lopes-Ferreira, P. Fernandes, A. Queirós, J. González-Méijome
{"title":"Combined Effect of Ocular and Multifocal Contact Lens Induced Aberrations on Visual Performance: Center-Distance Versus Center-Near Design","authors":"D. Lopes-Ferreira, P. Fernandes, A. Queirós, J. González-Méijome","doi":"10.1097/ICL.0000000000000355","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000355","url":null,"abstract":"Purpose: To evaluate the combined effects of inherent ocular aberrations and induced aberrations with a multifocal soft contact lens (MFCL) after 15 days of lens wear in presbyopic participants and their influence on visual performance at distance and near under high and low contrast conditions. Methods: Forty presbyopic participants (mean age, 48.7±3.4) presenting a mean addition of 1.53±0.58 D were fitted with Biofinity Multifocal (CooperVision) and included in the study. Measurements comprised distance and near monocular high (100%) and low contrast (10%) logMAR visual acuity (VA). Ocular aberrations were obtained with Hartmann–Shack aberrometer (IRX3, Imagine Eyes) and analyzed for 2 mm and maximum round natural pupil. Results: Distance VA was significantly higher in dominant eye, whereas near VA was significantly better in the non-dominant eye (P<0.05 in all conditions). For a 2-mm pupil in the dominant eye fitted with MFCL, spherical-like aberration significantly increased (P=0.027) so as higher-order aberrations (HOA) (P=0.002). A significant increase was also observed in spherical-like aberrations (P=0.001), coma-like aberrations (P=0.006) and HOA (P=0.004) in non-dominant eye. For the maximum round natural pupil size, a significant decrease in vertical coma was observed (P=0.018) in dominant eye, whereas a significant increase in spherical-like (P<0.001) and coma-like aberrations (P=0.007) was observed in non-dominant eye. A negative significant correlation was found between vertical coma and high contrast VA (Rho=−0.405, P=0.011) in dominant eye; whereas in non-dominant eye, a significant correlation was found between induced secondary astigmatism and distance VA under high (Rho=0.556, P<0.001) and low contrast (Rho=0.448, P=0.005). Conclusions: On-eye visual performance of MFSCL is dependent on the high-order aberrations induced by dominant and non-dominant design coupled with the wearer's inherent aberrations.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"147 1","pages":"S131–S137"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72717605","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
Application of CASIA SS-1000 Optical Coherence Tomography Tear Meniscus Imaging in Testing the Efficacy of New Strip Meniscometry in Dry Eye Diagnosis CASIA SS-1000光学相干断层扫描撕裂半月板成像在检验新型条形半月板测量在干眼诊断中的应用
Eye & Contact Lens: Science & Clinical Practice Pub Date : 2018-09-01 DOI: 10.1097/ICL.0000000000000312
Megumi Shinzawa, M. Doğru, Keiichi Miyasaka, J. Shimazaki, T. Sekiryu
{"title":"Application of CASIA SS-1000 Optical Coherence Tomography Tear Meniscus Imaging in Testing the Efficacy of New Strip Meniscometry in Dry Eye Diagnosis","authors":"Megumi Shinzawa, M. Doğru, Keiichi Miyasaka, J. Shimazaki, T. Sekiryu","doi":"10.1097/ICL.0000000000000312","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000312","url":null,"abstract":"Purpose: To investigate the applicability of CASIA SS-1000 anterior-segment optical coherence tomography (AS-OCT) imaging parameters in testing the efficacy of the new strip meniscometry (SM) namely “Strip Meniscometry Tube” (SMTube) in the diagnosis of dry eyes. Methods: Forty-three eyes of 22 patients (4 men and 18 women) with definite dry eye disease (DED) and 49 eyes of 28 normal controls (6 men and 22 women) were studied. All subjects underwent symptom questionnaires, SMTube, the Schirmer-1 test, tear film break-up time measurement, vital staining examinations, as well as tear meniscus height (TMH) and TM area (TMA) measurements using an AS-OCT system. We evaluated the cutoff values for the diagnosis of DED, looked into the correlations between TMH, TMA, and SMTube scores and checked the sensitivity and specificity of these parameters in the diagnosis of DED. Results: The mean values of TMH, TMA, and SMTube scores in the patient group were 0.138±0.102 mm, 0.013±0.015 mm2 and 1.4±2.3 mm, whereas those for the control group were 0.27±0.10 mm, 0.033±0.025 mm2 and 5.8±2.8 mm, respectively. The differences between both groups were significant (P<0.001). The cutoff values of TMH, TMA, and SMTube for DED were 0.197 mm, 0.020 mm2 and 3.8 mm, respectively. SMTube had significant correlations with TMH (r=0.82, P<0.001) and TMA (r=0.86, P<0.001). Conclusions: The SMTube was useful in DED diagnosis, the validity of which could be effectively evaluated by the CASIA SS-1000 AS-OCT TM parameters.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"54 1","pages":"S44–S49"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83323934","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信