2009 14th National Biomedical Engineering Meeting最新文献

筛选
英文 中文
Coarray sampling methods for forward looking IVUS imaging 前瞻性IVUS成像的阵列采样方法
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130318
C. Tekes, M. Karaman
{"title":"Coarray sampling methods for forward looking IVUS imaging","authors":"C. Tekes, M. Karaman","doi":"10.1109/BIYOMUT.2009.5130318","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130318","url":null,"abstract":"Forward looking intravascular ultrasound (IVUS) imaging with ring arrays can produce real time volumetric imaging. Due to the limited catheter size, data acquisition and image reconstruction are based on synthetic phased array processing to reduce the motion artifacts. The number of signal firing/receivening steps must be kept small. This can be achieved by reducing the redundant spatial frequency components. For this purpose, we explore different sampling methods. We tested the imaging performance of coarrays with different sampling schemes on the simulated point spred functions of original and control coarray sets. Simulation results show equivalent performance in 40 dB for an annular ring array of 64 elements with 2049 original and 350 reduced sets.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116438851","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Multi-channel acoustic mapping of respiratory system based on adventitious sound source separation 基于非定声源分离的呼吸系统多通道声学映射
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130366
I. Sen, M. Saraçlar, Y. Kahya
{"title":"Multi-channel acoustic mapping of respiratory system based on adventitious sound source separation","authors":"I. Sen, M. Saraçlar, Y. Kahya","doi":"10.1109/BIYOMUT.2009.5130366","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130366","url":null,"abstract":"The aim of this study is to localize the pathological compartments of the lung based on the characteristics of the modified pulmonary sounds. Sound signals recorded simultaneously at more than one point on the posterior chest wall are subjected to source separation methods in order to separate sound components associated with the disease. For this study, Basic Independent Component Analysis (BICA), Separation By Autocovariances (SBA) and Convolutive Blind Source Separation (CBSS), out of various source separation methods, are adopted and used. The measure proposed to find the most similar among the extracted independent components to the true source is kurtosis and Kullback-Liebler (K-L) distance. After the similarities between measured signals and the chosen component are located as coefficients onto the recording points on the chest wall and thereby formed matrix is visually improved via interpolation, a two-dimensional map is obtained, although with low resolution, showing estimated pathology source location and audibility distribution of the adventitious sound component around this source. This study is intended to be a pioneer to studies on acoustic-based respiratory system imaging which can function as an alternative to computer chest tomography in some necessary circumstances, and complementary in others.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130726102","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of anxiety related changes in skin conductance and blood volume pulse signals during coronary angiography 冠状动脉造影时皮肤电导和血容量脉搏信号焦虑相关变化的评价
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130285
S. Okkesim, M. H. Asyali, S. Kara, M. Kaya, İdris Ardiç
{"title":"Evaluation of anxiety related changes in skin conductance and blood volume pulse signals during coronary angiography","authors":"S. Okkesim, M. H. Asyali, S. Kara, M. Kaya, İdris Ardiç","doi":"10.1109/BIYOMUT.2009.5130285","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130285","url":null,"abstract":"Although, stress, sleep deprivation, excessive fatigue and inattention are common health problem in advanced society, there are many methodological problems that make it difficult to measure these emotional states in clinical situations. The main goal of this study is to investigate whether variation of stress due to treatment techniques used in a hospital setting can be successfully assessed and/or quantized using physiological variables. To this end, blood volume pulse and skin conductance signals of 8 patients who underwent angiography operation at the Cardiology Center of Erciyes University (Kayseri, Turkey), are obtained. Recordings were done at three stages: one hour before, during, and one hour after the angiography test. Our preliminary results indicate that the changes in the physiological variables across different subjects are remarkably consistent. This promising result is motivating us to consider and include other possible physiological variables and/or signals in our recording scheme to quantitatively assess changes in the emotional state of subjects undergoing critical operations.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134259303","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Fiber tracking using recursive stack data structure 光纤跟踪采用递归堆栈数据结构
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130350
D. G. Duru, M. Ozkan
{"title":"Fiber tracking using recursive stack data structure","authors":"D. G. Duru, M. Ozkan","doi":"10.1109/BIYOMUT.2009.5130350","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130350","url":null,"abstract":"In diffusion tensor magnetic resonance imaging (DT-MRI), each voxel is assigned a tensor that describes local water diffusion. In this study, the eigenvectors of the diffusion tensor are analyzed based on stack linked list application. The aim of the study is to develop a reliable and rapid tractography algorithm. The analyzed image sample consists of 60 diffusion weighted human brain images and a null image namely the T2 image creating a set of intensity images of size 256×256×60×30. The eigenvectors of D is calculated in every pixel, apparent diffusion coefficient ADC is represented with respect to D. The idea of the proposed method is to accomplish the fiber pathway by starting from a single, selected node taking every node in other words all the information of the eigenvector of the whole brain into account. Via the proposed study, an elimination method for the main drawback in DTI literature namely the uncertainty regions are aimed.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134486632","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Serbest dalgiclarda iYKAS ile serebrovaskuler reaktivite olcumu
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130332
Deniz Nevsehirli, Ata Akin
{"title":"Serbest dalgiclarda iYKAS ile serebrovaskuler reaktivite olcumu","authors":"Deniz Nevsehirli, Ata Akin","doi":"10.1109/BIYOMUT.2009.5130332","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130332","url":null,"abstract":"Effect of consecutive maximal dry breath-holds was compared between two groups of free divers with different experience levels and a control group. Hemoglobin concentration ([Hb], by functional near infrared spectroscopy, fNIRS), heart rate and systemic oxygen saturation (SO2, by pulse oxymetry) measurements were performed during four consecutive maximal dry breath-holdsChange in [Hb] (Δ[Hb]), change in SO2 (ΔSO2) and breath-hold indices (BHI_Δ[Hb], BHI_ΔSO2) normalized to hold durations calculated for each breath-hold. Analyses over these indices showed statistical difference between groups (p≪5×10−5 for both indices). Free diver groups exhibited a higher slope of increase of the indices among consecutive breath holds compared to the control group elucidating an enhanced reactivity to hypoxia. Our results indicate that cerebrovascular reactivity to hypercapnia can be learned and trained and the level of reactivity can be reliably quantified by fNIRS.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130783548","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Image processing method for artificial sight systems based on contrast information 基于对比度信息的人工视觉系统图像处理方法
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130320
M. Ozden, Nergis Karadoruk, I. Karagoz
{"title":"Image processing method for artificial sight systems based on contrast information","authors":"M. Ozden, Nergis Karadoruk, I. Karagoz","doi":"10.1109/BIYOMUT.2009.5130320","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130320","url":null,"abstract":"In this study, an image processing algorithm is developed for epiretinal implants. In this algorithm, it is presented an approach for adaptive frequency control that is one of the important parameters to generate stimuli. Standard 240×320 pixels video images in RGB format are processed as 10×10 pixel blocks. Consequently, it is designed to activate 24×32 pixels electrode matrix. As a retinal filter Gabor filter is preferred to DoG filter that is usually used in literature. The changes in pixels are modeled by using temporal filter. The results that belong to study and forward opinions are also presented.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"546 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133497355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Monte Carlo Simulation for photon migration in non-homogeneous medium 非均匀介质中光子迁移的蒙特卡罗模拟
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130301
R. U. Tok, Tamer Olmez, A. Akın
{"title":"A Monte Carlo Simulation for photon migration in non-homogeneous medium","authors":"R. U. Tok, Tamer Olmez, A. Akın","doi":"10.1109/BIYOMUT.2009.5130301","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130301","url":null,"abstract":"In this study, we developed a Monte Carlo Simulation for forward problem of photon migration in non-homogeneous medium. We validated our program against tMCimg, developed by Boas and colleagues, for some simple geometries. Eventually our program gives reasonable results for mediums which are not too complex but for more complex mediums because of very long computational time, it's not practical although theoretically there is no problem.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133449188","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Extendable intramedullary nail with mechanical loading 带机械载荷的可伸缩髓内钉
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130323
B. Uzun, O. Baran, H. Havitcioglu
{"title":"Extendable intramedullary nail with mechanical loading","authors":"B. Uzun, O. Baran, H. Havitcioglu","doi":"10.1109/BIYOMUT.2009.5130323","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130323","url":null,"abstract":"There are various extremity lengthening methods in the literature. Lentghening with intramedullary nails is also important method which is emphasized recent years. In this study, in the light of previous studies, it is aimed to develop a new expandable intramedullary system providing lengthening in order to remove previous problems and complications and to annihilate leg length discrepancies at present and future without second surgical intervention as far as possibble by lenghtening the intramedullary nail.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"15 11-12","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114012220","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Tissue welding by Thulium laser system: Predosimetry studies 铥激光系统组织焊接:预剂量学研究
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130347
A. Sennaroğlu, M. Gulsoy, H. Kalaycıoğlu, N. Topaloglu, A. Kurt, A. Sennaroğlu, M. Gulsoy
{"title":"Tissue welding by Thulium laser system: Predosimetry studies","authors":"A. Sennaroğlu, M. Gulsoy, H. Kalaycıoğlu, N. Topaloglu, A. Kurt, A. Sennaroğlu, M. Gulsoy","doi":"10.1109/BIYOMUT.2009.5130347","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130347","url":null,"abstract":"Laser tissue welding predosimetry studies are performed on Wistar rat skin by using diode-pumped and fiber-coupled Thulium (Tm:YAP) laser system emitting at 1980-nm, which is developed for medical applications. The success of laser tissue welding at 100 mW ve 160 mW of Tm:YAP laser powers is analyzed by macroscopy and histology results. Tm:YAP laser dosimetry of 100 mW, 5 second (34,66 W/cm2) is found successful for tissue welding studies.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114900550","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Immobilization of thrombin to bio/chemically modified synthetic fabrics 凝血酶在生物/化学改性合成织物上的固定化
2009 14th National Biomedical Engineering Meeting Pub Date : 2009-05-20 DOI: 10.1109/BIYOMUT.2009.5130346
Alper Akkaya, N. Pazarlıoğlu
{"title":"Immobilization of thrombin to bio/chemically modified synthetic fabrics","authors":"Alper Akkaya, N. Pazarlıoğlu","doi":"10.1109/BIYOMUT.2009.5130346","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2009.5130346","url":null,"abstract":"Processed synthetic polymers used in medical textile are used directly or functionalized by immobilization of bioactive molecules. Textile products made by synthetic polymers are durable, resistant to chemical reactions and have inert structures. Textile products made by synthetic polymers usually have not functional groups for immobilization. So modification could be done for formation of functional groups. Immobilization of bioactive molecules could be done by functional groups. In this study, thrombin was immobilized to textile products made by synthetic polymers. So Textile products made by synthetic polymers was added a new character which was blood stopper. The product was reliable because of source.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128310858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信