Energy eJournalPub Date : 2022-08-01DOI: 10.2139/ssrn.3933570
Simen Gaure, R. Golombek
{"title":"True or Not True CO2 Free Electricity Generation is Possible","authors":"Simen Gaure, R. Golombek","doi":"10.2139/ssrn.3933570","DOIUrl":"https://doi.org/10.2139/ssrn.3933570","url":null,"abstract":"Transition to a low-emission society requires radical emissions reductions in the electricity generation sector. Imposing that hourly load has to be served solely by wind power, solar PV and an energy storage technology, it is shown, using optimization and simulations of re-analysis data, how the EU can design a completely CO 2 emission-free electricity generation sector. For such a system, the optimal battery energy capacity should be 32 times of average hourly consumption of electricity in the EU. However, total production of electricity over a 10 year period is as much as 43 percent above total consumption of electricity.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115248827","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2022-07-01DOI: 10.2139/ssrn.3946172
F. Kara
{"title":"Effects of a Vertical Wall on Wave Power Absorptions with Wave Energy Converters Arrays","authors":"F. Kara","doi":"10.2139/ssrn.3946172","DOIUrl":"https://doi.org/10.2139/ssrn.3946172","url":null,"abstract":"The application of in-house transient wave-body interaction ITU-WAVE computational tool is extended to predict the wave power absorption with Wave Energy Converters (WECs) arrays in front of a vertical wall using time dependent boundary integral equation method. The vertical wall effect is considered with method of images which considers the perfect reflection from a vertical wall. The effects of separation distance between WECs as well as a vertical wall and WECs, and heading angles are studied for the prediction of wave power absorption, mean and individual interaction factors which determine the performances of WECs in an array system. The numerical results of WECs arrays in front of vertical wall show that both time and frequency dependent radiation and exciting force parameters are quite different from those of without vertical wall. The numerical investigations also demonstrate that wave power absorptions with an array system in front of a vertical wall are significantly greater than those of without vertical wall. This is due to nearly trapped and standing waves between a vertical wall and WECs. The prediction of hydrodynamic parameters in front of a vertical wall with present ITU-WAVE are validated against other published numerical and analytical results which show satisfactory agreements.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115065991","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2022-06-01DOI: 10.2139/ssrn.3908403
Raymond Li, C. Woo, A. Tishler, J. Zarnikau
{"title":"Price Responsiveness of Commercial Demand for Natural Gas in the US","authors":"Raymond Li, C. Woo, A. Tishler, J. Zarnikau","doi":"10.2139/ssrn.3908403","DOIUrl":"https://doi.org/10.2139/ssrn.3908403","url":null,"abstract":"To estimate price responsiveness of commercial demand for natural gas in the US, our panel data analysis uses five parametric specifications and monthly data for the lower 48 states in 1991-2020, finding (1) the statistically significant ( p -value ≤ 0.05) static own-price elasticity estimates are -0.137 to -0.245, short-run -0.152 to -0.261 and long-run -0.281 to -0.463; (2) these estimates varies by elasticity type, sample period, parametric specification, treatment of cross-section dependence (CD), and assumption of partial adjustment; (3) erroneously ignoring the highly significant ( p -value < 0.01) CD shrinks these elasticity estimates; (4) these elasticity estimates vary by season and region and their small size has been slowly declining over time; and (5) commercial natural gas shortage costs decline with the size of own-price elasticity estimates. The policy implications of these findings are: (a) price-induced conservation’s foreword looking effect on the US commercial natural gas demand is likely negligible, justifying continuation of standards for energy efficiency and CO 2 emissions and DSM programs for deep decarbonization; and (b) reducing an economy’s aggregate natural gas shortage cost may use critical peak pricing and/or forward contracts for firm and non-firm services.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"388 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116393197","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Experimental and Dft Studies of Oxygen Reduction Reaction Promoted by Binary Site Fe/Co-N-C Catalyst in Acid","authors":"Yu Han, Shuhu Yin, Youhu Chen, Chi Chen, Wei Yan, Xiao-Yue Cheng, Yanrong Li, Tianen Zhang, Jian Yang, Yanxia Jiang, Shigang Sun","doi":"10.2139/ssrn.3946129","DOIUrl":"https://doi.org/10.2139/ssrn.3946129","url":null,"abstract":"The cost and efficiency issues of cathodic electrocatalyst for oxygen reduction reaction (ORR) hinder a broad application of fuel cells. Therefore, it is necessary to develop highly efficient and sustainable ORR electrocatalysts of platinum group metal-free (PGM-free). The atomically dispersed FeCoNC-10 electrocatalysts were constructed by incorporating Fe phthalocyanine (FePc) molecules into bimetallic metal-organic frameworks (BMOF) followed by one-step pyrolysis. It showed remarkable ORR activity in acidic medium compared with FeNC and CoNC catalysts. The Fe-Co bimetallic sites were confirmed in FeCo-N-C, together with abundant isolated FeN 4 and CoN 4 sites. Theoretical study revealed that the bimetallic site can enhance O 2 adsorption and elongate O-O bond length rather than FeN 4 and CoN 4 . This can result in facile cleavage of the O-O bond and thus a direct 4e - ORR process. FeCoNC-10 catalyst showed enhanced ORR stability, due to very weak Fenton-type reaction related to Co species. Membrane electrode assemblies (MEAs) consisted of the FeCoNC-10 was applied in the cathode. It showed a peak power density of 100 mW cm -2 in a direct methanol fuel cells (DMFCs) with superior methanol tolerance. This work sheds light on the mechanism of atomically dispersed Fe/Co dual-doped carbon in enhancing ORR activity and stability, which enables the cost-effective ORR electrocatalyst design to achieve robust fuel cell performance.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115581987","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2021-04-07DOI: 10.2139/ssrn.3821572
J. Blackford, G. Alendal, S. Carpentier, H. Cremer, D. Dankel, M. Dewar, Bjarte Fargeras, S. Gasda, R. Heffron, M. Lien, A. Oleynik, A. Omar, R. Pawar, K. Romanak, Darren Snee, Sigrid Schutz, P. Torabi
{"title":"A Toolbox to Assist in Designing Marine Monitoring Programs for Offshore Storage Sites","authors":"J. Blackford, G. Alendal, S. Carpentier, H. Cremer, D. Dankel, M. Dewar, Bjarte Fargeras, S. Gasda, R. Heffron, M. Lien, A. Oleynik, A. Omar, R. Pawar, K. Romanak, Darren Snee, Sigrid Schutz, P. Torabi","doi":"10.2139/ssrn.3821572","DOIUrl":"https://doi.org/10.2139/ssrn.3821572","url":null,"abstract":"Over the last few years a number of computational approaches have been developed that enable the optimisation of marine monitoring strategies for CCS. These include methods to: simulate and quantify hypothetical release events, identify highly sensitive criteria by which to distinguish anomalous biogeochemistry which may indicate a seep and define minimum deployments of monitoring platforms which guarantee an acceptable chance of detection. In order for these tools to be operationally useful it is necessary to place them in an accessible and integrated digital format that allows the methodologies to be applied coherently to multiple offshore storage sites and to answer specific stakeholder led questions around required sensitivity, cost and assurance levels. In this work we describe progress towards achieving this integration as well as the site specific data necessary to generate bespoke monitoring guidance.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129441554","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2021-04-07DOI: 10.2139/ssrn.3821716
Francesco Magli, Maurizio Spinelli, M. Fantini, M. Romano, M. Gatti
{"title":"Techno-Economic and Off-Design Analysis of Two CO2 Purification Units for Low-Carbon Cement Plants with Oxy-Fuel Calcination","authors":"Francesco Magli, Maurizio Spinelli, M. Fantini, M. Romano, M. Gatti","doi":"10.2139/ssrn.3821716","DOIUrl":"https://doi.org/10.2139/ssrn.3821716","url":null,"abstract":"This paper presents the techno-economic assessment of the CO2 Purification Unit (CPU) included in cement plants based on CO2 capture via oxy-fuel calcination. Two configurations, targeting two different outlet CO2 specifications (‘moderate’ and ‘high’ purity), have been optimized in order to minimize the increase in the clinker production cost due to this process unit. Air infiltration rate is the parameter with the highest impact on the operational conditions (e.g. separation pressure) and on the incremental cost of clinker due to the CPU (up to 20% for the worst case considered). The work has been carried out within the framework of the CLEANKER project.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134014336","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2021-04-05DOI: 10.2139/ssrn.3819867
M. Masoudi, H. Fazeli, R. Miri, H. Hellevang
{"title":"Toward Probabilistic Modeling of Halite Nucleation and Growth during Carbon Storage Process: Pore Scale Modeling","authors":"M. Masoudi, H. Fazeli, R. Miri, H. Hellevang","doi":"10.2139/ssrn.3819867","DOIUrl":"https://doi.org/10.2139/ssrn.3819867","url":null,"abstract":"To maximize safety and cost-efficiency of CO2 storage, it is necessary to understand how a high permeability in the near-well region is maintained. Nucleation and growth of salt crystals driven by the evaporation of formation water into under-saturated (dry) super-critical CO2 stream results in the changes in the porosity and permeability of the near well-bore area. Permeability reduction is the main reason of the injectivity loss in the context of CO2 storage in saline aquifers. According to recent studies, during CO2 storage, salt crystals form in two different forms: 1) single, large crystals in the aqueous phase, and 2) aggregates of micrometer size salt crystals in the gas phase. All the previous numerical studies at pore-scale addressed the formation of single, large crystals in the aqueous phase. In this work, we developed a 3D pore-scale reactive transport solver (a D3Q19 advection-diffusion Lattice-Boltzmann model) and took nucleation process into account via a new probabilistic approach to simulate the formation of micro-meter size salt crystals in the gas phase and their effect on changes in pore morphology and permeability for the first time. Comparing the results of porosity-permeability relation with some of the well-known clogging models, confirms the need for a new clogging model to capture the permeability reduction caused by salt aggregates.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125749729","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2021-04-02DOI: 10.2139/ssrn.3768026
Nicolas Boccard
{"title":"Nuclear Power vs. Renewables: a scale perspective","authors":"Nicolas Boccard","doi":"10.2139/ssrn.3768026","DOIUrl":"https://doi.org/10.2139/ssrn.3768026","url":null,"abstract":"A low carbon electricity generating technology will contribute to the energy transition only if it is able to scale up. From that perspective, we compare nuclear, wind and solar power with respect to the size of a typical power plant, across the criteria of physical scalability, build- ing experience and financial lumpiness. Because size differs by 3 orders of magnitude between these technologies, markedly different findings obtain, providing a convincing rationale for the relative successes and failures of the industries behind each. We conclude that smaller devices such as solar panels allow for more innovation, more financing and thus a faster diffusion. By the same token, we see no end in sight for the problems afflicting nuclear power. We make a modest case for the novel modular concept even though it falls pray to the same essential defects. The tendency toward gigantism afflicting wind power may brings forth the difficulties nuclear power has faced for long.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114971963","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2021-02-26DOI: 10.15587/1729-4061.2021.225327
V. Nerubatskyi, O. Plakhtii, D. Hordiienko, S. Mykhalkiv, Vasyl Ravluyk
{"title":"A Method for Calculating the Parameters of the Sine Filter of the Frequency Converter, Taking into Account the Criterion of Starting Current Limitation and Pulse-Width Modulation Frequency","authors":"V. Nerubatskyi, O. Plakhtii, D. Hordiienko, S. Mykhalkiv, Vasyl Ravluyk","doi":"10.15587/1729-4061.2021.225327","DOIUrl":"https://doi.org/10.15587/1729-4061.2021.225327","url":null,"abstract":"An analysis of the method for ensuring the sinusoidality of the output voltage in power generation systems with self-commutated voltage inverters under the requirements of the international standard IEEE-519 is presented.<br><br>In a number of programs, especially low-power generation systems, a low-cost solution is needed to provide the sinusoidal waveform of the output voltage with the total harmonic distortion of 5 %. This solution is to use two-level voltage inverters with an output sine LC filter. However, the feature of the sine filter with the frequency converter is that the PWM frequency affects the spectrum of higher harmonics of the output voltage. In addition, there is the starting current of the filter capacitor, which can disable the power switches of the voltage inverter.<br><br>The developed method for calculating the values of the LC filter with the two-level voltage inverter in the PWM mode is presented meeting the requirements of the international standard IEEE-519, taking into account the modulation frequency and limitation of the starting current of the filter capacitor.<br><br>To confirm the required quality of the output voltage of the two-level voltage inverter with the sine filter, an appropriate simulation model was created in the Matlab/Simulink computer simulation environment. The oscillograms and harmonic analysis of the input and output voltages of the sine filter, which showed the total harmonic distortion of 1.88 %, are presented.<br><br>A physical prototype of the investigated system was created on the basis of a 5.5 kW OVEN PChV203-5K5-V frequency converter (Ukraine). Using the SIGLENT SDS1104X-E oscilloscope (China), the real waveform and the results of the harmonic analysis of the sine filter output voltage, confirming the implementation of the necessary sinusoidality criteria, were obtained","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"223 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122900343","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Energy eJournalPub Date : 2021-01-06DOI: 10.2139/ssrn.3760958
Smruti Ranjan Panda, P. Behera
{"title":"Experimental Research on the Performance of Environmental Friendly Refrigerant Mixtures in a Vapour Compression Refrigeration System","authors":"Smruti Ranjan Panda, P. Behera","doi":"10.2139/ssrn.3760958","DOIUrl":"https://doi.org/10.2139/ssrn.3760958","url":null,"abstract":"Today's refrigeration and air-conditioning industry is adopting chlorine- and fluorine-free working fluids, because chlorine is the cause of depleting the ozone layer, and fluorine is the cause of global warming. CFC12 is a more suitable refrigerant recognized in vapor compression refrigeration systems. It was phased out in developed countries in 1996. It is recommended to use HFC134a for replacing CFC12 in vapor compression refrigeration systems. But HFCs have a high global warming potential. The \"Kyoto Protocol\" aims to reduce the whole GHG emissions by at least 5-times over the 1990 level during the commitment period from 2008 to 2012. Therefore, in the near future, the production and utilization of HFC134a will be ended. There are millions of heat pumps and air-conditioners in refrigeration systems that use CFC12 and HFC134a in the world that must be properly retrofitted under the aforementioned phase-out. However, there are few studies on the replacement of HFC134a refrigerant. This motivates the use of some available environmentally friendly fluids to replace the new product lines of CFC12 and HFC134a to study the performance of the new product line of vapor compression refrigeration systems. But none of them are environmentally acceptable substitutes. In the work of this project, refrigerant R290/R600a (68/32% by weight), R290/R600 (79/21% by weight) is used for the performance of vapor compression refrigeration system), LPG (R290/R600/R600a-33/53)/14 wt.%) and LPG/R134a (60/40 wt.%) have been experimentally studied as modifications of CFC12 and HFC134a. Finally try to predict system performance under the action of a magnetic field. Six magnets are placed on the full liquid pipeline at the outlet of the condenser, and each magnet has a level of 4000 Gauss. Due to the magnetic field, the power consumption of the compressor is decreased by 2.5%, and the COP is reduced by 2.4%. \u0000 \u0000The results of this study prove that the new alternative refrigerants R290/R600a (68/32 wt.%) and R290/R600 (79/21 wt.%) mixtures can well replace CFC12 and HFC134a, and can be used without any modification. It can be used to transform the old system. The refrigerants LPG and LPG/R134a (60/40% by weight) can be used for higher evaporation temperature applications.","PeriodicalId":111306,"journal":{"name":"Energy eJournal","volume":"84 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131909184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}