{"title":"Multi-fault diagnosis method for insulation condition of power transformer based upon cloud model","authors":"Jiyu Wang, R. Liao, Yiyi Zhang","doi":"10.1109/ICPADM.2015.7295334","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295334","url":null,"abstract":"Power transformer constitutes the core component of power system for energy transmission and distribution. The operation status of power transformer directly affects the security and stability of the power grid operation. Any faults of power transformer can result in significant economic losses. Monitoring and diagnosis provide an effective way to detect the potential fault. However, the traditional approach is often limited for the concurrent potential multi-fault, and is also prone to make serious diagnostic deviation due to its definite thresholds. Predicated on this background, this paper is inspired by the innovative engineering model and then proposes an improved model to diagnose the multi-fault of power transformer accurately. Through this way, it aims to present a more efficient approach than the previous ones. Specifically, the new multi-fault diagnosis method can realize the transition from the precise quantitative numerical value to the qualitative evaluation concept, which is described as digital characteristics. Consequently, the collected data can be analyzed by the reasoning rules in the perspective of qualitative cloud concept. Once the relationship between the fault type and the cloud concept is determined, the diagnosis results can be deduced from the characteristic gas with different contents which has already been converted to the qualitative concept. A case study proves the feasibility and validity of the proposed model, and offers a new way for the multi-fault diagnosis of power transformer.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114687875","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Comparative studies of partial discharge using acoustic emission method and optical spectroscopy","authors":"T. Boczar, D. Zmarzły, P. Fracz","doi":"10.1109/ICPADM.2015.7295378","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295378","url":null,"abstract":"This paper concerns improvement of evaluation methods of partial discharge (PD), which may occur in the power transformer insulation systems. This particular study regards the next stage of research works, which aim to determine the energy share of particular physical phenomena accompanying generation of PD. The performed works were connected to comparative analysis of PDs, which were measured with the acoustic emission (AE) method and with optical spectroscopy. The applied measurement setup was specially designed for generation of surface partial discharges (SPDs) in transformer oil as insulation medium. In the introduction section elements of the experimental setup, i.e. the spark gap for modeling of SPDs and the transformer tank model filled with insulation oil will be characterized. Further the measurement equipment and the metrological parameters for both applied PDs registration methods will be described in detail. In the following sections the achieved results will be presented and discussed. In particular spectra of optical signals registered in the range from 200 to 1100 nm and frequency spectra of AE signals registered in the range from 0 to 500 kHz will be presented. In order to determine the effect of voltage value, which was used for generation of SPD, on the registered optical and AE signals, the results will be presented for three relative values: 0.6, 0.7 and 0.8 times the value of breakdown voltage of the applied test system. In addition, results of time-frequency analysis of EA signals, in the form of two dimensional spectrograms calculated using the short time Fourier transform will be presented. In the following section the achieved results of performed comparative analysis will be presented and discussed.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"7 12","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120841228","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"HDPE nanocomposites using nanoclay, MWCNT and intumescent flame retardant characteristics","authors":"B. N. Rao, T. Praveen, R. Sailaja, M. Khan","doi":"10.1109/ICPADM.2015.7295396","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295396","url":null,"abstract":"Nanocomposites of high density polyethylene (HDPE) along with nanoclay (NC), acid functionalized multiwalled carbon nanotubes (MWCNT) and pentaerythritol phosphate (PEPA) have been developed. In order to enhance the interfacial adhesion, HDPE grafted glycidyl methacrylate has been added to the composites. An improvement in mechanical properties and flammable characteristic for the nanocomposites has been observed using both nanoclay and MWCNT and was further analysed using micromechanical models.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134166133","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of leakage current on the residual resistance of an ice surface","authors":"B. Porkar, M. Farzaneh","doi":"10.1109/ICPADM.2015.7295354","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295354","url":null,"abstract":"In static and dynamic arc models to predict AC and DC critical flashover voltages of an ice-covered insulator, residual resistance for a given value of the length of the arc and feeding water conductivity is assumed to be constant. For this hypothesis, however, the thermal effects on an ice surface are not taken into consideration. In this paper an accurate model to figure out joule heating effect over an ice-covered insulator is presented where (a) water film layers are assumed to have different conductivities, and (b) Joule heating due to leakage current and liquid falling off the water film due to gravity are considered with the first effect increasing water film thickness and the second one decreasing it.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"89 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122691371","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of absorbed moisture on the dielectric properties of epoxy resin impregnated paper composites","authors":"Hongliang Zhang, X. Ning, Hua Feng, Peng Liu, Chuang Wang, Zongren Peng","doi":"10.1109/ICPADM.2015.7295361","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295361","url":null,"abstract":"The absorbed moisture of epoxy resins (ER) and epoxy resin impregnated paper (ERIP) composites have a great influence on the insulation of ultra-high voltage direct current (UHVDC) bushings. The ER and ERIP samples were prepared according to a certain formulation. The moisture absorption behaviors of ER and ERIP in deionized water were determined by measuring periodically the change of weight. Through comparing the absorption behaviors, it is found that ERIP samples absorbed more moisture than ER samples, and the moisture diffusion in ERIP samples can't be described by one dimensional Fickian or Langmuir-type model. The dielectric spectra of ER and ERIP samples were measured over the frequency range of 10-2 to 106 Hz at five different temperatures. As measurement temperatures were below the glass transition temperature of ER, the low frequency dispersion wasn't observed in dielectric spectra of ER and ERIP samples within absorbed moisture in this work. The results show that the absorbed moisture has a much greater influence on dielectric properties of ERIP samples than ER samples. The absorbed moisture in ER samples only slightly increases imaginary parts of relative permittivity of ER samples and shift the spectra to right, while the absorbed moisture greatly increase both real and imaginary parts of relative permittivity of ERIP samples. The near-Debye relaxations occurred in middle frequency ranges in ERIP samples within absorbed moisture, which may be caused by Maxwell-Wagner interfacial polarization or dipole polarization of water molecular.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122837009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Understanding impact of copper sulphide diffusion into pressboard insulation in transformers","authors":"K. S. Yaday, R. Sarathi, M. Danikas","doi":"10.1109/ICPADM.2015.7295306","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295306","url":null,"abstract":"Surface discharge inception voltage (SDIV) in copper sulphide diffused Oil Impregnated Pressboard (OIP) material reduces with increases in harmonic content in the supply voltage, irrespective of Total Harmonic Distortion (THD). The rise time of current signal injected during Surface discharge process is about few ns and the Fast Fourier transform (FFT) analysis of Ultra High Frequency (UHF) signal formed due to surface discharge process have dominant frequency of 0.9 GHz. The characteristics are the same irrespective of level of thermal aging of OIP and amount of DBDS present in transformer oil. The amplitude and width of the current pulse increases with increases due to aging. Atomic Absorption Spectroscopy (AAS) studies results indicate that the amount of copper content in pressboard material have increased with increasing in concentration level of DBDS. Energy dispersive spectroscopy (EDS) conform the amount of copper and sulphur is high with thermally aged OIP due to aging of OIP in transformer oil with DBDS concentration. Attenuated Total Reflectance - Fourier Transform Infrared (ATR-FTIR) spectroscopy studies indicates the formation of aldehydes and carboxylic acids, caused due to degradation of cellulose structure. Phase Resolved Partial Discharge (PRPD) analysis indicates that the surface discharge activity occurs near the peak of the applied AC/harmonic AC voltages at inception voltage and at rising portion of the applied AC/harmonic AC voltage at higher voltages. The tensile and flexural strength of the material reduces with thermal aging of OIP material, irrespective of concentration of DBDS in oil.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115640474","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yan Pei, Z. Qian, Jixi Lu, Fengtao Liu, Xiao-Dong Zhao
{"title":"Development of UHF PD monitoring system based on FPGA","authors":"Yan Pei, Z. Qian, Jixi Lu, Fengtao Liu, Xiao-Dong Zhao","doi":"10.1109/ICPADM.2015.7295443","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295443","url":null,"abstract":"Gas insulated switchgear (GIS) is widely used in high voltage power transmission systems. Condition of GIS is crucial for the whole transmission system. PD (Partial discharge) signal, which contains information about the state of GIS, is important for GIS condition monitoring. An ultra-high frequency (UHF) PD on-site monitoring system of 10 channels, including PD detection system and supervisory system, is designed in this paper. The PD detection system is designed based on field-programmable gate array (FPGA). Supervisory system configures PD detection system and recognizes PD patterns. Laboratory GIS defect models are developed in this paper. Experiment result shows that the system can recognize four common patterns of PD. Furthermore, a monitoring network could be built by several PD detection systems and a supervisory system.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"85 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122206763","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Yao, Z. Chang, H. Mu, Jun-bo Deng, Guanjun Zhang
{"title":"Two-dimension simulation of small scale dielectric barrier discharge in argon","authors":"C. Yao, Z. Chang, H. Mu, Jun-bo Deng, Guanjun Zhang","doi":"10.1109/ICPADM.2015.7295289","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295289","url":null,"abstract":"Low temperature plasma generated by dielectric barrier discharge (DBD) has been paid more and more attention in recent years for its wide range of potential applications. In this paper, atmospheric argon DBD is ignited in a small gas gap of 0.1mm between two parallel glass plates covered by circular copper electrodes with a radius of 0.7 mm. A two-dimension axisymmetric numeric model, coupled with fluid and Poisson equations, is built to clarify the discharge evolution. The basic process of discharge, mainly controlled by electron energy and electric field, is analyzed, which is divided into three stages including Townsend-like discharge, streamer development and discharge extinction. Through the simulation, the spatial-temporal distribution of electron, space charge, surface charge and electric field are investigated, which indicates that the space charge plays a key role in the development of discharge. When the DBD is driven by applied voltage, five discharge channels can be found at the end of the discharge current pulse. The electric field distorted by space charge is expected to be responsible for movement of ionization wave. The surface charge is believed to be the main factor affecting the distribution of five discharge channels.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114518287","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Komatsu, Tomoyuki Izutsu, Y. Ohki, M. Mizuno, K. Fukunaga
{"title":"Terahertz spectroscopic observation of oxidation of ethylene-propylene-diene-copolymer","authors":"M. Komatsu, Tomoyuki Izutsu, Y. Ohki, M. Mizuno, K. Fukunaga","doi":"10.1109/ICPADM.2015.7295329","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295329","url":null,"abstract":"Flame-retardant ethylene-propylene-diene copolymer, which is the polymer insulating material most abundantly used for safety-related electric cables in nuclear power plants, was irradiated with gamma-rays to certain designated doses from 500 to 1500 kGy at room temperature or 100 °C in air, and absorption spectra were measured at terahertz frequencies. A broad absorption is induced by the irradiation in a range from 0.5 to 3.1 THz. It is confirmed that this absorption is induced by oxidation, by comparing its frequency spectrum with spectra of polyethylene obtained numerically by doing quantum chemical calculations and experimentally by measuring its absorption at THz frequencies. Therefore, the degree of oxidation of this copolymer can be estimated by the intensity of the broad absorption at these THz frequencies.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"81 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123609852","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Chuanyang Li, Jinliang He, Jun Hu, Boya Zhang, Guixin Zhang
{"title":"Dynamic observation of dc surface charge dissipation for epoxy-resin/alumina composite","authors":"Chuanyang Li, Jinliang He, Jun Hu, Boya Zhang, Guixin Zhang","doi":"10.1109/ICPADM.2015.7295283","DOIUrl":"https://doi.org/10.1109/ICPADM.2015.7295283","url":null,"abstract":"The low surface DC flashover voltage for the cone-type insulator has restrained the industrial application of high voltage apparatus especially for gas-insulated substation and gas-insulated transmission lines. However, the surface charge under DC, which produces uniform electric fields resulting in surface flashover under low direct voltage, are still not investigated clearly. In this paper, the dissipation characteristics of the surface charges are studied and the mechanism of the dissipation for surface voltage potential is discussed. The experiment sample is from a 550kV cone-type insulator of GIS with the surface shined by 220# sandpaper, and cut into the size of 140mm×40mm×4mm. 30kV was applied by a cylinder electrode for 10 minutes in atmosphere. To gain the dissipation characteristics of the surface voltage potential, several consecutive points along the insulator surface were chosen, and the voltage potential was detected continuously with an electrostatic probe after the voltage being removed. In addition, the overall surface potential was detected by sliding the probe along the surface of the insulator. The results showed that only negative voltage potential appeared along the surface when the voltage was applied. After the voltage was removed, the surface potential suffered great changes and positive charges were found “flooding” suddenly from both electrodes and moving towards the middle of the insulator surface with time. Only positive voltage potential was detected on the surface after more than 6 hours.","PeriodicalId":110155,"journal":{"name":"2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115358086","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}