P. Landsmann, J. Jung, M. Kramkowski, P. Stolze, D. Paulus, R. Kennel
{"title":"Lowering injection amplitude in sensorless control by means of current oversampling","authors":"P. Landsmann, J. Jung, M. Kramkowski, P. Stolze, D. Paulus, R. Kennel","doi":"10.1109/SLED.2012.6422810","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422810","url":null,"abstract":"Sensorless control approaches for low and zero speed determine the rotor position by injecting high frequency voltage signals. Current measurement noise and quantization necessitate a minimum amount of injection amplitude, which implies an acoustic noise emission that for many applications is unacceptable. This paper proposes to sample the current with the maximum AD conversion frequency while processing the data with an FPGA. By means of a recursive least squares method and a theoretical extension, high precision current slopes are calculated from low injection voltage. Experimental results show that the injection magnitude could be reduced by factor 7 to 10 compared to standard PWM centered current measurement, but also that such weak excitation shifts the HF injection approach to a scale where normally negligible effects have to be taken into consideration.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122706984","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Efficiency optimization of a sensorless V/f control method for PMSM","authors":"S. H. Jafari, K. Corzine, Jing Huang","doi":"10.1109/SLED.2012.6422807","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422807","url":null,"abstract":"This paper presents a V/f control for permanent magnet synchronous machines which focuses on optimization by minimizing the d-axis current in order to reduce the motor losses, and supplied input power. The proposed sensorless method only needs machine terminal signals and does not require any additional motor parameter measurements. Minimization of the d-axis current is accomplished through computed reactive power.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122119876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis and tests of the sensorless rotor position detection of ringed-pole PM motor","authors":"L. Alberti, M. Morandin, N. Bianchi, S. Bolognani","doi":"10.1109/SLED.2012.6422800","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422800","url":null,"abstract":"A novel strategy is presented to compute the high-frequency signal injection response of a ringed-pole electrical machine. The self-sensing capability of the machine is evaluated by means of a small-signal model of the machine in the d-q reference frame and finite-element simulations. The proposed procedure is validated by the comparison with other simulation strategies and experimental results.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126808280","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of stator saturation on the differential inductances of PM-synchronous machines with concentrated winding","authors":"J. Graus, A. Boehm, I. Hahn","doi":"10.1109/SLED.2012.6422809","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422809","url":null,"abstract":"For sensorless position detection of permanent magnet synchronous machines at very low speed and standstill, signal injection methods are commonly used. As a prerequisite these so called saliency-tracking methods require a differential magnetic anisotropy of the machine, which is both position and load dependent and thus varying during operation. So the performance of sensorless operation strongly depends on the machine design. To investigate the influence of the stator saturation a machine model based on a magnetic equivalent circuit is presented in this document. This model is then used to analyze the differential inductances of a machine with concentrated windings. The results show that for some angles of the current vector the inductances do not vanish even for high currents. This phenomenon is explained by analyzing the flux paths.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125674898","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Accuracy and robustness improvement in sensorless PMSM drives at low-speed by direct-axis current injection","authors":"S. Calligaro, R. Petrella","doi":"10.1109/SLED.2012.6422798","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422798","url":null,"abstract":"Speed control accuracy and robustness in sensorless drives based on non-salient PMSMs, especially in the low-speed region, are critical issues mainly due to the low amplitude of the back-EMF, being the main information that state observers are normally exploiting, [1]-[4]. Open-loop control (e.g. constant amplitude rotating current space vector), is normally employed to start the motor up to an enough high speed, where sensorless closed-loop control is possible. Extension of the closed-loop control range towards zero is however strongly desired. Besides the adopted estimation techniques, it has been shown experimentally that adding an arbitrary direct-axis current component to the current reference leads to an important improvement in the feedback control capability, [2][5]. This phenomenon can be intuitively explained by considering that the rotor magnetic axis tends to align to the current vector angle, then the estimated direct-axis current forces convergence of estimated and actual position. In this paper, an unpublished analytical explanation of this effect is presented, while extensive simulation and experimental investigations demonstrate the effectiveness of the adopted approach and the resulting advantages in an actual sensorless industrial drive system.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"126 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116475854","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sensorless quasi-standstill and very low-speed position detection in non-salient PMSMs based on current injection and back-EMF observer","authors":"S. Bolognani, S. Calligaro, R. Petrella","doi":"10.1109/SLED.2012.6422813","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422813","url":null,"abstract":"Accuracy and robustness of sensorless speed control of non-salient PMSMs in the low-speed region and at start-up is a critical issue, due to the low amplitude of the back-EMF which prevents estimation and then closed-loop control in the zero speed range. This problem is usually overcome by adopting an open-loop control (e.g. constant amplitude rotating current space vector), which is normally able to start the motor up to an enough high speed, where sensorless closed-loop control is possible. Open-loop startup is however not robust against load torque and inertia variations and random initial rotor position conditions. Also the extension of the closed-loop operating range towards zero is strongly desired. Standard techniques relying on magnetic saliency are not applicable (i.e. no relevant anisotropy is present in the considered machine), and some methods based on the detection of torque production by signal injection can be adopted. The methods proposed and studied in this paper belongs to this last class. Two different application cases will be considered: an initial high-accuracy position detection at quasi-standstill and a position and speed tracking for closed-loop sensorless speed control. A complete theoretical analysis is reported to demonstrate the features of the proposal and highlight the dependence on certain design parameters. Then extensive simulation and experimental investigations based on an industrial drive system are included to prove the feasibility of the method and validity of the theoretical analysis.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124726104","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Self-sensing control of PM synchronous machines including online system identification based on a novel MRAS approach","authors":"K. Wiedmann, Axel Mertens","doi":"10.1109/SLED.2012.6422822","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422822","url":null,"abstract":"Some of the remaining challenges of self-sensing control for permanent magnet synchronous machines (PMSM) are: combination of EMF-based and magnetic saliency-based methods, influence of the fundamental current control on saliency-based methods, position-transducerless system identification of key parameters or mitigation of distortion effects, respectively, and reduction of computational effort. The authors present a novel Model Reference Adaptive System (MRAS) approach which takes these demands into account. In this paper, the focus is set on identification of saturation-dependent inductances and mitigation of harmonic estimation errors. A linear approximation of saturation effects is achieved within an auto-commissioning process. Furthermore an adaptive filter is presented mitigating harmonic estimation errors which are caused by multiple saliencies e.g. Thus in contrast to passive filter structures a good bandwidth of the self-sensing control is achieved. Experimental results demonstrate a good performance of self-sensing control for the entire speed range including dynamic operation (with maximal loading), although no offline measurements/identification of the drive system was applied.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"118 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133130532","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Thiemann, C. Mantala, T. Mueller, R. Strothmann, E. Zhou
{"title":"PMSM sensorless control with Direct Flux Control for all speeds","authors":"P. Thiemann, C. Mantala, T. Mueller, R. Strothmann, E. Zhou","doi":"10.1109/SLED.2012.6422812","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422812","url":null,"abstract":"A sensorless method named Direct Flux Control (DFC), which only requires the different voltages between a neutral point of permanent magnet synchronous machine (PMSM) and an artificial neutral point during switching states of pulse width modulation (PWM) signals, is implemented on a real time system with a PMSM. The DFC method is a continuous excitation method and can attain the estimated rotor position for all speeds. Moreover, in this paper the estimated position is assured as the exact rotor flux position, which is strongly needed in almost of the motor control schemes. The investigation of the DFC structure has been proposed and achieved, which allows for the frame conversion calculation. The derivation of the frame conversion is included. Furthermore, the closed loop sensorless speed control with DFC is also proposed and implemented. The proposed scheme can accurately perform with high robustness. All experiments and results of each part are elaborated, discussed and analyzed.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115621889","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"LPV observer for PMSM with systematic gain design via convex optimization, and its extension for standstill estimation of the position without saliency","authors":"A. Zgorski, B. Bayon, G. Scorletti, X. Lin-Shi","doi":"10.1109/SLED.2012.6422818","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422818","url":null,"abstract":"This paper presents a new efficient and systematic method to optimize the gain of the Linear Parameter-Varying (LPV) observer for a surface-mounted Permanent Magnet Synchronous Motor (PMSM). The said gain will be calculated by convex optimization to induce a convergence of the observer in a predetermined speed range. An extension of the observer to zero-speed estimation of position is also proposed, using a new model of the machine taking an injection signal into account, and without the use of saliency.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115422564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Compensating angle estimation errors caused by magnetic saturation in anisotropy-based sensorless control schemes","authors":"S. Kuehl, P. Landsmann, R. Kennel","doi":"10.1109/SLED.2012.6422803","DOIUrl":"https://doi.org/10.1109/SLED.2012.6422803","url":null,"abstract":"In anisotropy-based sensorless control schemes, the influence of magnetic saturation is usually neglected. This causes angle estimation errors, especially under high-load conditions. By applying a more accurate machine model, this error can be effectively compensated. The present work gives a short introduction to the non-linear model applied and analyzes the angle errors in both, open-loop and closed-loop sensorless operation. Additionally, an algorithm is proposed, that uses the model information to compensate the angle estimation error. The effectiveness of this approach is verified by measurements on a synchronous reluctance machine.","PeriodicalId":104196,"journal":{"name":"3rd IEEE International Symposium on Sensorless Control for Electrical Drives (SLED 2012)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124813872","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}