{"title":"Simulation of multi-mode parallel hybrid electric vehicle using fuzzy logic","authors":"A. Benny, Liny Geevarghese Tharakan","doi":"10.1109/ICGT.2012.6477979","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477979","url":null,"abstract":"Petroleum resources are dwindling day by day and the atmospheric pollution created by gasoline vehicles force the researchers to develop new, eco-friendly, highly efficient vehicles. In this paper, the design of a new multimode parallel hybrid electric vehicle is considered. The design technique uses fuzzy logic for implementing various controlling actions. The vehicle is fitted with electric motors, generators and conventional internal combustion engines for higher power requirements and energy saving purpose. The simulation of the parallel hybrid electric vehicle is done using LabVIEW software. The simulation successfully shows the different configurations expected to be used by the automotive industry in the new phase of hybrid vehicles. LabVIEW simplifies the simulation by offering a robust Fuzzy Logic Controller Design Tool Kit and an interactive graphical user interface for easy controlling.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"258 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114466074","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Pollution of Ashtamudi estuary and ground water due to dumping of municipal solid wastes at Kureepuzha, Kollam, and its environmental impacts","authors":"M. Najee, M. Philipose","doi":"10.1109/ICGT.2012.6477968","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477968","url":null,"abstract":"This study is focused on the variation of physico-chemical parameters in water samples taken from two different sites of the lake and from five wells near the dumpsite. The Dissolved Oxygen (DO) content and Total Dissolved Solids(TDS) content of most of the samples are beyond the standard limits. The chloride content near the dumpsite is found to be very high compared to the non-polluted site of the lake.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122096680","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"One dimensional modelling of oxygen diffusion in a gas diffusion layer of PEM Fuel Cell","authors":"N. Rakesh, M. Shaneeth, S. Jayaraj","doi":"10.1109/ICGT.2012.6477997","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477997","url":null,"abstract":"In this paper, we present one dimensional single phase model of diffusion in a gas diffusion layer of PEM Fuel Cell. During the operation of a Fuel Cell, gas, water vapour and liquid water get transported at different rates through the porous structure of gas diffusion layer. Fick's law of diffusion, Knudsen diffusion, pressure driven flow and capillary pressure are considered to describe the flow under various circumstances within the layer,. Porosity and tortuosity of the layer play major roles in deciding the flow conditions. We are presenting results of studies on the flow of oxygen gas through the Gas Diffusion Layer (GDL). MATLAB/SIMULINK platform was used for this purpose.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"85 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124648972","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analytical and experimental analysis of optimal tilt angle of solar photovoltaic systems","authors":"Anu George, Robins Anto","doi":"10.1109/ICGT.2012.6477978","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477978","url":null,"abstract":"Performance of PV panel depends on the tilt angle of the panel with respect to the horizontal plane. The tilt angle determines the amount of solar insolation on panel surface and intern determines quantity of energy collected. Conventionally the best tilt angle is equivalent to latitude of the location at which panel is installed. The value of optimal tilt angle at defined location depends on local atmospheric condition, altitude of region, movement of sun etc. So the value of optimal tilt angle varies over each month. In this paper the values of optimal tilt angle over each month for a PV panel installed in Kerala, India (9.55°N, 76.81°E) was theoretically estimated using geographic factor method, clearness index method and declination angle method. The results showed that the gain in the amount of solar radiation throughout the year received by the PV panel mounted at monthly optimum tilt angles with respect to seasonal optimum angles and tilt angle equal to latitude were 3.4% and 7%, respectively. The theoretically estimated values of optimal tilt angles are used as a base for experimental investigation. Experimental investigation was done for three months and it is found that the geographic factor method is the best method among three methods.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124478970","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sensorless vector control of SVPWM inverter fed induction machine using MRAS-sliding mode","authors":"G. Nisha, Z. V. Lakaparampil, S. Ushakumari","doi":"10.1109/ICGT.2012.6477943","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477943","url":null,"abstract":"One of the most important technologies for electric vehicles is the drive control technology which does not require a position or speed sensor. In a sensorless vector controlled induction machine, the speed must be estimated from the system measurements. Model Reference Adaptive System (MRAS) based techniques are one of the best methods to estimate the rotor speed due to its performances and straight forward stability approach. The performance of the traditional rotor flux MRAS with PI controller deteriorates due to integrator drift and sensitivity to current measurement noise. Practically, system tuning is difficult and may yield under damped responses. In this paper, a new robust MRAS scheme based on sliding mode technique to estimate the rotor speed of a sensorless vector controlled induction machine is proposed. Further, a space vector pulse width modulated (SVPWM) voltage source inverter is used to feed the induction machine rather than the traditional sinusoidal PWM inverter for the simulation. The drive system with the proposed adaptive mechanism is simulated by MATLAB/Simulink to verify the principles of the technique and compared its performance with that of PI controller.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125445869","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Siddiqui, S. Khan, S. Ahsan, M. I. Khan, A. Annamalai
{"title":"Application of phase shifting transformer in Indian Network","authors":"A. Siddiqui, S. Khan, S. Ahsan, M. I. Khan, A. Annamalai","doi":"10.1109/ICGT.2012.6477970","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477970","url":null,"abstract":"This paper presents an integrated optimal power flow with phase shifter approach to enhance power system reliability, availability, loss optimization & system security. Overloading of sub system in a power system sometimes may pose stability issues, which may lead to unwanted Outages & Blackouts, equipment failure which will result long repair replacement cycle, cost of repair and heavy revenue losses. Under these conditions, to ensure economical and reliable operation of the grid, power through the lines should be controlled within their limits. To control power flow phase shifting transformer (PST) is one of the cheaper option. The application of phase shifting transformer will control the real power flow in transmission lines. To realize a variable phase angle shift, on load tap changers could be deployed to vary the control voltage there by change in the resultant phase angle. Simulation of One of the cases for Uttar Pradesh Network is described in this paper. The simulation work of network justifies the application of PST.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"159 12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128917006","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance analysis of cooperative wireless network with grouping based selection combining","authors":"S. Muthukumar, V. Nagarajan","doi":"10.1109/ICGT.2012.6477938","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477938","url":null,"abstract":"Cooperative diversity is one of the emerging areas in modern wireless network, where each user transmits their own data to the base station and also serves as a relay for other user. For the purpose of relay selection and cooperation, protocols are needed to form groups. Grouping is done based upon the instantaneous Signal to Noise Ratio (SNR) of user to base station channel and the corresponding target rate of the user. We use this strategy to perform grouping based selection combining scheme for a single relay cooperative system. The symbol error probability (SEP) for this scheme minimizes when incorporating the effect of the source relay link.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117099858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Scoping in EIA using Rapid Impact Assessment Matrix - A case study","authors":"J. Vivek, K. Shibu","doi":"10.1109/ICGT.2012.6477957","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477957","url":null,"abstract":"Solid waste arising from human and animal activities, comprises of countless different materials which are difficult to name them all. Sanitary landfills have been and continue to be an economical method for solid waste disposal especially in developing countries. The solid waste management problem is getting aggravated in the capital city of Kerala, Trivandrum with current generation of around 280-300 metric tons per day and disposing the same in low-lying areas without taking proper precautions which has led to breeding of rodents, flies and other domestic pests and also pollution of air, surface water and ground water. This paper reports the results of the scoping process in Environmental Impact Assessment (EIA) study that was conducted for the feasibility of converting the solid waste dumping site into a sanitary landfill. Scoping study was carried out using Rapid Impact Assessment Matrix (RIAM) method. The impacts of various activities were evaluated against the different environmental and socio-economic components and for each component a score was determined, which provides a measure of the impact expected from the component. It was found that most of the environmental components like Sociology and Culture, Biology and Ecology have scored positive values for the conversion option.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121467770","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Seismic damage assessment of exterior beam-column joint","authors":"S. Shyma, S. Sivakumar, K. R. Bindhu, P. V. Sudha","doi":"10.1109/ICGT.2012.6477973","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477973","url":null,"abstract":"In earthquake-resistant design of reinforced concrete structures, it is generally necessary to permit some degree of damage; otherwise the design would be too costly. In order to implement this philosophy properly, models for assessing structural damage within the context of a random earthquake environment are required. One objective of the seismic design process is to limit the locations of damage and to ensure that damage at these locations is within acceptable limits. To facilitate the quantification of damage in analysis and design, it is helpful to define damage in terms of a numerical `damage index'. Damage indices are potentially valuable design tools, since they provide a means by which different design or retrofit options can be compared objectively. Damage models are usually based on the maximum deformations, hysteretic energies and structural deteriorations. Damage indices are suitable tools for quantifying numerically the damage in structures sustained under earthquake loading. In this work damage index is calculated by Park - Ang model, Rao model, Meyer model and Sadeghi model for the exterior beam-column joint and were compared.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127804085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Green energy from Space Solar Power - A technical feasibility study","authors":"S. Joy, T. J. Apren, C. Venugopal","doi":"10.1109/ICGT.2012.6477989","DOIUrl":"https://doi.org/10.1109/ICGT.2012.6477989","url":null,"abstract":"This paper describes the importance, general principle and main factors that must be considered in the design of a system both onboard as well as the ground segment, for a Space Solar Power system. Also explained are the design and realization of a functional demonstration model of the system (microwave to DC), especially the detector circuit that is part of rectenna system, which converts microwave energy into electricity.","PeriodicalId":103634,"journal":{"name":"2012 International Conference on Green Technologies (ICGT)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132873000","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}