Chemia Analityczna最新文献

筛选
英文 中文
The Macrophage in Wound Healing Surrounding Implanted Devices 巨噬细胞在植入装置周围伤口愈合中的作用
Chemia Analityczna Pub Date : 2009-12-07 DOI: 10.1002/9780470567319.CH2
M. Godek, D. Grainger
{"title":"The Macrophage in Wound Healing Surrounding Implanted Devices","authors":"M. Godek, D. Grainger","doi":"10.1002/9780470567319.CH2","DOIUrl":"https://doi.org/10.1002/9780470567319.CH2","url":null,"abstract":"","PeriodicalId":9751,"journal":{"name":"Chemia Analityczna","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2009-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"50659589","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Nitric Oxide-Releasing Subcutaneous Glucose Sensors 一氧化氮释放皮下葡萄糖传感器
Chemia Analityczna Pub Date : 2009-12-07 DOI: 10.1002/9780470567319.CH9
H. S. Paul, M. Schoenfisch
{"title":"Nitric Oxide-Releasing Subcutaneous Glucose Sensors","authors":"H. S. Paul, M. Schoenfisch","doi":"10.1002/9780470567319.CH9","DOIUrl":"https://doi.org/10.1002/9780470567319.CH9","url":null,"abstract":"","PeriodicalId":9751,"journal":{"name":"Chemia Analityczna","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2009-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"50659647","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Surface‐Enhanced Raman Spectroscopy for Glucose Sensing 表面增强拉曼光谱用于葡萄糖传感
Chemia Analityczna Pub Date : 2009-12-07 DOI: 10.1002/9780470567319.CH15
N. Shah, J. Yuen, O. Lyandres, M. Glucksberg, J. Walsh, R. V. Duyne
{"title":"Surface‐Enhanced Raman Spectroscopy for Glucose Sensing","authors":"N. Shah, J. Yuen, O. Lyandres, M. Glucksberg, J. Walsh, R. V. Duyne","doi":"10.1002/9780470567319.CH15","DOIUrl":"https://doi.org/10.1002/9780470567319.CH15","url":null,"abstract":"","PeriodicalId":9751,"journal":{"name":"Chemia Analityczna","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2009-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"50659586","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Single‐Cell Measurements with Mass Spectrometry 单细胞质谱测量
Chemia Analityczna Pub Date : 2006-08-24 DOI: 10.1002/9780470119501.CH12
E. B. Monroe, J. Jurchen, S. Rubakhin, J. Sweedler
{"title":"Single‐Cell Measurements with Mass Spectrometry","authors":"E. B. Monroe, J. Jurchen, S. Rubakhin, J. Sweedler","doi":"10.1002/9780470119501.CH12","DOIUrl":"https://doi.org/10.1002/9780470119501.CH12","url":null,"abstract":"","PeriodicalId":9751,"journal":{"name":"Chemia Analityczna","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2006-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"51147908","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Improving the response behavior of Cd-selective polymeric membrane electrodes by incorporated lipophilic particles. 通过加入亲脂性颗粒改善镉选择性聚合物膜电极的响应行为。
Chemia Analityczna Pub Date : 2006-01-01
Reto Thürer, Tamás Vigassy, Martina Hirayama, Ernö Pretsch
{"title":"Improving the response behavior of Cd-selective polymeric membrane electrodes by incorporated lipophilic particles.","authors":"Reto Thürer, Tamás Vigassy, Martina Hirayama, Ernö Pretsch","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The influence of incorporated lipophilic particles on the potentiometric response behavior of two Cd(2+)-selective membranes is described. The particles show only minor influence on the selectivity behavior of the membranes. As described earlier for a similar Ca(2+)-selective membrane, the flux of primary ions from the sample to the membrane can be successfully suppressed by the incorporation of lipophilic particles.</p>","PeriodicalId":9751,"journal":{"name":"Chemia Analityczna","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2844670/pdf/nihms183011.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"28873592","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Shifting the Measuring Range of Chloride Selective Electrodes and Optodes Based on the Anticrown Ionophore [9]Mercuracarborand-3 by the Addition of 1-Decanethiol. 通过添加 1-Decanethiol 改变基于反皇冠离子体 [9]Mercuracarborand-3 的氯化物选择性电极和光电极的测量范围。
Chemia Analityczna Pub Date : 2005-01-01
Aleksandar Radu, Eric Bakker
{"title":"Shifting the Measuring Range of Chloride Selective Electrodes and Optodes Based on the Anticrown Ionophore [9]Mercuracarborand-3 by the Addition of 1-Decanethiol.","authors":"Aleksandar Radu, Eric Bakker","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Ion-selective electrodes and optodes based on the anticrown ionophore mercuracarborand-3 (MC-3) exhibit excellent selectivity to halide ions but suffer from a low upper detection limit because of very strong complexation in the sensing phase. In this work, we have successfully improved the upper detection limit and widened the working range of chloride selective electrode based on MC-3 by introducing 1-decanethiol into the membrane cocktail. With an assumed 1:2 stoichiometry between chloride and MC-3 the apparent complex formation constant was reduced from log beta = 13.4 as reported for the membrane without the addition of 1-decanethiol to log beta = 12.13, log beta = 10.84 and log beta = 5.67 with the addition of a 1:1, 1:2 and 1:4 molar ratio of 1-decanethiol to MC-3. Besides these values, obtained with the sandwich membrane method, similar shifts in the measuring range of thin optode film responses to lower chloride concentrations were observed as well. The selectivity of the modified membrane was found to be very good, with hydroxide and the other halides: bromide and iodide, as the main interferences. Based on these results, corresponding iodide selective electrodes were prepared that showed a near-Nernstian iodide slope, rather than a cationic slope as observed without thiol additive.Jonoselektywne elektrody i optody stosujace antykoronowy jonofor [9]merkuracarborand-3 (MC-3) charakteryzuja sie doskonała selektywnościa w stosunku do jonów halogenków lecz wskutek silnego kompleksowania w fazie receptora maja ograniczony zakres górnej granicy oznaczalności. W przedstawionej pracy poszerzono zakres stosowalności dzieki wprowadzeniu 1-dekanotiolu do membrany zawierajacej MC-3. Przy załozonej stechiometrii kompleksu chlorek-MC-3 równej 1:2 stała tworzenia kompleksu została obnizona, z wartości log beta = 13,4 (w przypadku membrany bez dodatku 1-dekanotiolu) do wartości log beta = 12,13; log beta = 10,84 i log beta = 5,67 (po dodaniu 1-dekanotiolu) dla stosunków molowych stezeń-1-dekanotiol:MC-3 wynoszacych odpowiednio 1:1, 1:2 i 1:4. Ponadto oprócz tych danych otrzymanych metoda warstwowej membrany, podobne przesuniecie zakresu pomiarowego obserwowano w przypadku małych stezeń chlorków dla cienkowarstwowej optody. Selektywnoś ć modyfikowanej membrany była dobra, przy czym głównymi interferentami były jony bromkowe, jodkowe i wodorotlenkowe. W oparciu o te wyniki skonstruowano elektrode czuła na jony jodkowe, charakteryzujaca sie nachyleniem anionowym charakterystyki bliskim Nernstowskiemu, a nie kationowym wykazywanym w nieobecności tiolu.</p>","PeriodicalId":9751,"journal":{"name":"Chemia Analityczna","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2005-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1307496/pdf/nihms2759.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25814619","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Capillary isoelectric focusing 毛细管等电聚焦
Chemia Analityczna Pub Date : 1998-01-01 DOI: 10.1201/9781482289855-11
J. Wiktorowicz
{"title":"Capillary isoelectric focusing","authors":"J. Wiktorowicz","doi":"10.1201/9781482289855-11","DOIUrl":"https://doi.org/10.1201/9781482289855-11","url":null,"abstract":"","PeriodicalId":9751,"journal":{"name":"Chemia Analityczna","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"65969243","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信