The engineers journal最新文献

筛选
英文 中文
Modern reassessment of the Citicorp Building design wind loads. 花旗大厦设计风荷载的现代再评估。
The engineers journal Pub Date : 2020-01-01
Dat Duthinh
{"title":"Modern reassessment of the Citicorp Building design wind loads.","authors":"Dat Duthinh","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Following structural engineering practice of the 1970s, engineers designed the Citicorp Building for the action of wind in each of the structure's principal axes. One problem they faced was how to determine design values by combining simultaneous wind loads from the means and root mean squares of these loads. Given the technology available at the time, the simplifying assumption was made of decomposing the effects of a corner wind into the sum of the effects on two adjacent faces, as if these wind loads were static and perfectly correlated, which they are not. As a result of this assumption, the connections in the diagonal braces were deemed overstressed, and emergency repairs had to be performed on the just completed building. Nowadays, the Database-Assisted Design method and modern computer technology are capable of accounting for simultaneous dynamic loads properly, performing structural analyses for all time steps where measurements are available, and extrapolating to longer duration windstorms using extreme value distributions. Modern analysis thus determines design loads on a more rational basis and shows that the combinations of wind loads that caused such concern in 1978 do not need to be considered for mean recurrence intervals of practical interest.</p>","PeriodicalId":93233,"journal":{"name":"The engineers journal","volume":"NA ","pages":"online"},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8240663/pdf/nihms-1658816.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39149063","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Blown away: Citicorp Center Tower repairs revisited. 震撼:花旗集团中心大厦的修复工作再次进行。
The engineers journal Pub Date : 2019-07-01
Dat Duthinh
{"title":"Blown away: Citicorp Center Tower repairs revisited.","authors":"Dat Duthinh","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Using Database-Assisted Design and the Tokyo Polytechnic University Aerodynamic Database, we show that face winds put more structural demand than corner winds do on the Citicorp Tower in Manhattan. This 59-story building, supported by four midside columns, famously had to undergo secret emergency strengthening shortly after its completion in the 1970s to withstand corner winds.</p>","PeriodicalId":93233,"journal":{"name":"The engineers journal","volume":"NA ","pages":"online"},"PeriodicalIF":0.0,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8240665/pdf/nihms-1658807.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39149064","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信