Analytica (Basel, Switzerland)最新文献

筛选
英文 中文
Iodine and Bromine Analysis in Human Urine and Serum by ICP-MS, Tailored for High-Throughput Routine Analysis in Population-Based Studies. 用ICP-MS分析人类尿液和血清中的碘和溴,用于基于人群的研究的高通量常规分析。
Analytica (Basel, Switzerland) Pub Date : 2026-03-01 Epub Date: 2026-01-06 DOI: 10.3390/analytica7010006
Thieli Schaefer Nunes, Lucas Schmidt, Kayla Peterson, Rosalind Wright, Julio Alberto Landero-Figueroa
{"title":"Iodine and Bromine Analysis in Human Urine and Serum by ICP-MS, Tailored for High-Throughput Routine Analysis in Population-Based Studies.","authors":"Thieli Schaefer Nunes, Lucas Schmidt, Kayla Peterson, Rosalind Wright, Julio Alberto Landero-Figueroa","doi":"10.3390/analytica7010006","DOIUrl":"10.3390/analytica7010006","url":null,"abstract":"<p><p>Iodine is essential for thyroid hormone synthesis and is particularly critical during pregnancy, where excess and mainly its deficiencies can impair fetal neurodevelopment and increase maternal complications. Bromine has also gained attention due to its potential to interfere with iodine metabolism and contribute to adverse health effects when present in excess. Monitoring iodine and bromine in biological samples, especially urine and serum, is therefore important for assessing thyroid function and population health. This work presents a simple and robust ICP-MS method for simultaneous determination of bromine and iodine in urine and serum. The procedure uses a 20-fold dilution with 10 mmol L<sup>-1</sup> ammonia containing 0.1% (<i>w</i>/<i>w</i>) EDTA-2Na, ensuring solution stability, minimizing sample-to-sample variability, and eliminating the need for matrix-matched calibration. EDTA-2Na effectively prevents precipitation of metal species at high pH, avoiding blockages in the sample introduction system. Method accuracy was confirmed through certified reference materials and spike-recovery experiments, both showing suitable agreement for the two analytes. Precision was consistently strong (RSD < 6%), and low detection limits were achieved (0.78 μg L<sup>-1</sup> for Br and 0.24 μg L<sup>-1</sup> for I). The use of a high-efficiency nebulizer enabled analysis with only 50 μL of sample, making the method suitable for limited-volume specimens. Overall, this approach provides a sensitive, accurate, and practical solution for large-scale population studies and clinical applications.</p>","PeriodicalId":521102,"journal":{"name":"Analytica (Basel, Switzerland)","volume":"7 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13101949/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147795953","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Improved and Novel Methods for Investigating Organophosphate Esters in Particulate Matter. 研究颗粒物中有机磷酸酯的改进和新方法。
Analytica (Basel, Switzerland) Pub Date : 2024-12-01 Epub Date: 2024-10-02 DOI: 10.3390/analytica5040032
Annie Gathof, Tess Bonanno, Paige Rossicone, Adelaide E Clark
{"title":"Improved and Novel Methods for Investigating Organophosphate Esters in Particulate Matter.","authors":"Annie Gathof, Tess Bonanno, Paige Rossicone, Adelaide E Clark","doi":"10.3390/analytica5040032","DOIUrl":"10.3390/analytica5040032","url":null,"abstract":"<p><p>A pressurized liquid extraction (PLE) method for the extraction of 31 organophosphate esters (OPEs) and novel organophosphate esters (NOPEs) has been developed. Unlike previously published methods, this method utilizes the high-throughput nature of PLE (as opposed to Soxhlet or sonication methods) without using potentially harmful organic solvents like methylene chloride. Combinations of hexane and acetone and hexane and ethyl acetate at various temperatures were examined. Extracts were concentrated and analyzed via gas chromatography-mass spectrometry. The final optimized method utilized 1:1 <i>v</i>/<i>v</i> hexane/ethyl acetate at 100 °C for three static cycles (5 min each) at 80% flush volume and a 100 s N<sub>2</sub> purge. This provided average surrogate corrected target analyte percent recoveries in spike and recovery experiments (<i>n</i> = 6) for OPEs and NOPEs of 106 ± 13%, with average surrogate recoveries of 88.6 ± 7.3%. The developed method was further validated using standard reference materials and was then applied to atmospheric particulate matter samples collected in the city of Providence, RI. The dataset reflected ambient concentrations of 16 OPEs and NOPEs (reported in pg m<sup>-3</sup>) for the first time in the greater Providence metropolitan area, including one of the first reports of NOPEs in atmospheric particulate matter in the U.S.</p>","PeriodicalId":521102,"journal":{"name":"Analytica (Basel, Switzerland)","volume":"5 4","pages":"471-480"},"PeriodicalIF":0.0,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12621544/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145553087","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书