{"title":"Variable-Fidelity Surrogate Model-Based Airfoil Optimization at a Moderate Reynolds Number","authors":"Adrija Das, M. Sivapragasam","doi":"10.61653/joast.v76i1.2024.937","DOIUrl":"https://doi.org/10.61653/joast.v76i1.2024.937","url":null,"abstract":"Airfoil shape optimization for enhanced aerodynamic performance at a moderate Reynolds number is carried out using a novel technique for constrained optimization of expensive engineering functions. The proposed method is a co-kriging surrogate model using two levels of fidelity in conjunction with a gradient-free trust-region method to drive the model towards the global optimum. The methodology is first applied on a generic test function to demonstrate its efficiency. Later, the proposed optimization framework is applied on constrained airfoil shape optimization problems involving maximizing the lift-to-drag ratio, maximizing the endurance factor, and minimizing the drag coefficient of an Eppler E214 airfoil. The optimal lift-to-drag ratio and the endurance factor are found to be 13.25% and 16.05%, respectively, higher than the baseline airfoil. The optimal drag coefficient is 6.86% lower than the baseline airfoil. The flow transition is also delayed for the some of the optimal airfoils. The present results show that the proposed optimization methodology is successful in improving the aerodynamic characteristics in the sensitive low/moderate Reynolds number regime.","PeriodicalId":515959,"journal":{"name":"Journal of Aerospace Sciences and Technologies","volume":"301 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140719389","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of Heating Rate on Melting Point of HMX, RDX, TNT and PETN","authors":"Roshnee Das, Nikhilesh S. Trivedi","doi":"10.61653/joast.v76i1.2024.938","DOIUrl":"https://doi.org/10.61653/joast.v76i1.2024.938","url":null,"abstract":"Melting point of HMX, RDX, TNT and PETN are measured for judging crystal purity. The heating rate when doing this has a significant effect on the melting point reading. This work gives an insight on how heating rate affects the melting point reading for these high explosives using Differential Scanning Calorimetry (DSC). With increase in heating rates (from 1 to 20°C min-1) the different behaviours of the DSC curves for HMX, RDX, TNT and PETN are analysed. It is also observed from this study that heating rate causes a shift in the temperatures for onset and the peak for HMX, RDX, TNT and PETN. This study reflects that in some cases the decomposition of the explosives is influencing the melting graphs. Hence a conclusion has been drawn on the adequate heating rate that should be chosen for determining the melting point of these high explosives.","PeriodicalId":515959,"journal":{"name":"Journal of Aerospace Sciences and Technologies","volume":"45 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140716908","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Assessment of Halon-Free Agents for Fire Safety Application in Aircraft Propulsion System","authors":"A. Dinesh, Michael Diakostefanis, Suresh Sampath","doi":"10.61653/joast.v76i1.2024.939","DOIUrl":"https://doi.org/10.61653/joast.v76i1.2024.939","url":null,"abstract":"Halon 1301 is an effective total flooding fire suppression agent which is widely employed in aircraft cargo and propulsion systems for emergency fire scenarios. The production of Halon 1301 was banned by the Montreal Protocol in 1994 due to its environmental impact on ozone depletion and long atmospheric lifetime. Thus, a credible alternative is required for fire safety application on-board aircrafts. This study forms a follow-up to the work published by A. Dinesh et.al and M. Diakostefanis et.al which studied halon-free fire suppression in aircraft cargo bay through CFD and experimental validation respectively. Due to constraints in cost and logistics of testing fire suppression in a gas turbine engine, a computer modelled fire zone of a hypothetical high-bypass turbofan engine was used to simulate and evaluate the fire suppression performance of three Halon-free agents - HFC-125, HFC-227ea and FIC-13I1. Halon 1301 was also simulated to provide baseline comparison to the alternative agents. The capacity to inert was based on the distribution of agent concentrations subjected to a heptane-based fuel fire. Simulations were conducted at ISASLS and 40,000 feet to represent the engine’s operating environment. Overall, it was found that HFC-125 and HFC-227ea satisfactorily suppressed fire at both ambient scenarios. It was found that agent density and suppression concentration significantly influenced the agent’s ability to mix with ambient air and flood the fire zone. Density of the agent combined with higher inertion concentrations also influenced formation of localised recirculation zones which influenced mixture distribution in the fire zone. The simulations enabled identification of individual changes to agent flow characteristics at different operating conditions and demonstrated the performance criteria of Halon 1301 along with the proposed alternative agents for successful fire suppression. Through this study, it was found that all the agents except FIC-13I1 passed the minimum suppression criteria making HFC-125 and HFC-227ea suitable agents for replacement of Halon 1301. The minimum concentration and simulation design in the engine fire zone were validated against the experimental tests conducted by NIST in Boeing 777’s dual-spool high bypass turbofan engine for Halon 1301 and HFC-125. The failure of FIC-13I1 was attributed to the complex design in fire zone and could be overcome by considering a higher factor of safety for this design and injecting higher mass flow rate of the agent into the fire zone. The outcome of this study proposes further work to be carried out through experimental validation of the CFD simulations which will be key to progress the technology to higher TRL and meet aviation certification requirements. Further work may also explore blended agent configurations to tailor the agent characteristics to meet suppression requirements for maintaining safety and reliability of the system.","PeriodicalId":515959,"journal":{"name":"Journal of Aerospace Sciences and Technologies","volume":"2011 25","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140718745","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}