{"title":"Transductive and Transfer Learning","authors":"B. Lavine, K. Booksh, Sharon L. Neal","doi":"10.3390/jeta2020005","DOIUrl":"https://doi.org/10.3390/jeta2020005","url":null,"abstract":"For most of the twentieth century, chemistry has been a data-poor discipline relying on well-thought-out hypotheses and carefully planned experiments to develop solutions to real-world problems [...]","PeriodicalId":498653,"journal":{"name":"Journal of Experimental and Theoretical Analyses","volume":"58 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141342120","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jian Feng, M. Herrmann, Anne-Maria Reinecke, Antonio Hurtado
{"title":"Active Brazing for Energy Devices Sealing","authors":"Jian Feng, M. Herrmann, Anne-Maria Reinecke, Antonio Hurtado","doi":"10.3390/jeta2010001","DOIUrl":"https://doi.org/10.3390/jeta2010001","url":null,"abstract":"The pursuit of reliable energy devices sealing solutions stands as a paramount engineering challenge for ensuring energy safety and dependability. This review focuses on an examination of recent scientific publications, primarily within the last decade, with a central aim to grasp and apply critical concepts relevant to the efficient design and specification of brazements for ceramic–metal active-brazed assemblies, emphasizing the sealing of energy devices. The goal is to establish robust and enduring joints capable of withstanding water-vapor and hydrogen environments. The review commences with a concise recapitulation of the fundamental principles of active brazing, followed by an in-depth exploration of material selection, illustrated using water-vapor-resistant sensors as illustrative examples. Furthermore, the review presents practical solutions for the sealing of energy devices while also scrutinizing the factors that exert significant influence on the deterioration of these active-brazed connections. Ultimately, the review culminates in a comprehensive discussion of emerging trends and developments in active brazing techniques for energy-related applications.","PeriodicalId":498653,"journal":{"name":"Journal of Experimental and Theoretical Analyses","volume":"59 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139532812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Application of Fluorescence Anisotropy for Viscosity Measurements of Small Volume Biological Analytes","authors":"M. Sydor, Monica A. Serban","doi":"10.3390/jeta1020007","DOIUrl":"https://doi.org/10.3390/jeta1020007","url":null,"abstract":"Time-resolved fluorescence anisotropy has been extensively used to detect changes in bimolecular rotation associated with viscosity levels within cells and other solutions. Physiological alterations of the viscosity of biological fluids have been associated with numerous pathological causes. This current work serves as proof of concept for a method to measure viscosity changes in small analyte volumes representative of biological fluids. The fluorophores used in this study were fluorescein disodium salt and Enhanced Green Fluorescent Protein (EGFP). To assess the ability of the method to accurately detect viscosity values in small volume samples, we conducted measurements with 12 µL and 100 µL samples. No statistically significant changes in determined viscosities were recorded as a function of sample volume for either fluorescent probe. The anisotropy of both fluorescence probes was measured in low viscosity standards ranging from 1.02 to 1.31 cP, representative of physiological fluid values, and showed increasing rotational correlation times in response to increasing viscosity. We also showed that smaller fluid volumes can be diluted to accommodate available cuvette volume requirements without a loss in the accuracy of detecting discrete viscosity variations. Moreover, the ability of this technique to detect subtle viscosity changes in complex fluids similar to physiological ones was assessed by using fetal bovine serum (FBS) containing samples. The presence of FBS in the analytes did not alter the viscosity specific rotational correlation time of EGFP, indicating that this probe does not interact with the tested analyte components and is able to accurately reflect sample viscosity. We also showed that freeze–thaw cycles, reflective of the temperature-dependent processes that biological samples of interest could undergo from the time of collection to analyses, did not impact the viscosity measurements’ accuracy. Overall, our data highlight the feasibility of using time-resolved fluorescence anisotropy for precise viscosity measurements in biological samples. This finding is relevant as it could potentially expand the use of this technique for in vitro diagnostic systems.","PeriodicalId":498653,"journal":{"name":"Journal of Experimental and Theoretical Analyses","volume":"7 11","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138625302","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mou Adhikari, Rola Houhou, Julian Hniopek, Thomas Bocklitz
{"title":"Review of Fluorescence Lifetime Imaging Microscopy (FLIM) Data Analysis Using Machine Learning","authors":"Mou Adhikari, Rola Houhou, Julian Hniopek, Thomas Bocklitz","doi":"10.3390/jeta1010004","DOIUrl":"https://doi.org/10.3390/jeta1010004","url":null,"abstract":"Fluorescence lifetime imaging microscopy (FLIM) has emerged as a promising tool for all scientific studies in recent years. However, the utilization of FLIM data requires complex data modeling techniques, such as curve-fitting procedures. These conventional curve-fitting procedures are not only computationally intensive but also time-consuming. To address this limitation, machine learning (ML), particularly deep learning (DL), can be employed. This review aims to focus on the ML and DL methods for FLIM data analysis. Subsequently, ML and DL strategies for evaluating FLIM data are discussed, consisting of preprocessing, data modeling, and inverse modeling. Additionally, the advantages of the reviewed methods are deliberated alongside future implications. Furthermore, several freely available software packages for analyzing the FLIM data are highlighted.","PeriodicalId":498653,"journal":{"name":"Journal of Experimental and Theoretical Analyses","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136237717","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ana Paula Giussani Mocellin, Rafael Pereira Maciel, Phelype Haron Oleinik, Elizaldo Domingues dos Santos, Luiz Alberto Oliveira Rocha, Juliana Sartori Ziebell, Liércio André Isoldi, Bianca Neves Machado
{"title":"Geometrical Analysis of an Oscillating Water Column Converter Device Considering Realistic Irregular Wave Generation with Bathymetry","authors":"Ana Paula Giussani Mocellin, Rafael Pereira Maciel, Phelype Haron Oleinik, Elizaldo Domingues dos Santos, Luiz Alberto Oliveira Rocha, Juliana Sartori Ziebell, Liércio André Isoldi, Bianca Neves Machado","doi":"10.3390/jeta1010003","DOIUrl":"https://doi.org/10.3390/jeta1010003","url":null,"abstract":"Given the increasing global energy demand, the present study aimed to analyze the influence of bathymetry on the generation and propagation of realistic irregular waves and to geometrically optimize a wave energy converter (WEC) device of the oscillating water column (OWC) type. In essence, the OWC WEC can be defined as a partially submerged structure that is open to the sea below the free water surface (hydropneumatic chamber) and connected to a duct that is open to the atmosphere (in which the turbine is installed); its operational principle is based on the compression and decompression of air inside the hydropneumatic chamber due to incident waves, which causes an alternating air flow that drives the turbine and enables electricity generation. The computational fluid dynamics software package Fluent was used to numerically reproduce the OWC WEC according to its operational principles, with a simplification that allowed its available power to be determined, i.e., without considering the turbine. The volume of fluid (VOF) multiphase model was employed to treat the interface between the phases. The WaveMIMO methodology was used to generate realistic irregular waves mimicking those that occur on the coast of Tramandaí, Rio Grande do Sul, Brazil. The constructal design method, along with an exhaustive search technique, was employed. The degree of freedom H1/L (the ratio between the height and length of the hydropneumatic chamber of the OWC) was varied to maximize the available power in the device. The results showed that realistic irregular waves were adequately generated within both wave channels, with and without bathymetry, and that wave propagation in both computational domains was not significantly influenced by the wave channel bathymetry. Regarding the geometric evaluation, the optimal geometry found, H1/Lo = 0.1985, which maximized the available hydropneumatic power, i.e., the one that yielded a power of 25.44 W, was 2.28 times more efficient than the worst case found, which had H1/L = 2.2789.","PeriodicalId":498653,"journal":{"name":"Journal of Experimental and Theoretical Analyses","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135063365","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}