Sensors, Circuits and Instrumentation Systems最新文献

筛选
英文 中文
Low Voltage Low Power Analog Circuit Design OTA Using Signal Attenuation Technique and Applications 基于信号衰减技术的低电压低功耗OTA模拟电路设计及应用
Sensors, Circuits and Instrumentation Systems Pub Date : 2019-11-05 DOI: 10.1515/9783110592566-001
Karima Garradhi, N. Hassen
{"title":"Low Voltage Low Power Analog Circuit Design OTA Using Signal Attenuation Technique and Applications","authors":"Karima Garradhi, N. Hassen","doi":"10.1515/9783110592566-001","DOIUrl":"https://doi.org/10.1515/9783110592566-001","url":null,"abstract":"","PeriodicalId":438065,"journal":{"name":"Sensors, Circuits and Instrumentation Systems","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125797578","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Myopathy’s Diagnosis System Based on Surface EMG Signal Acquisition, Analysis and Classification 基于表面肌电信号采集、分析和分类的肌病诊断系统
Sensors, Circuits and Instrumentation Systems Pub Date : 2019-11-05 DOI: 10.1515/9783110592566-002
Rim Barioul, S. F. Ghribi, H. Derbel, O. Kanoun
{"title":"A Myopathy’s Diagnosis System Based on Surface EMG Signal Acquisition, Analysis and Classification","authors":"Rim Barioul, S. F. Ghribi, H. Derbel, O. Kanoun","doi":"10.1515/9783110592566-002","DOIUrl":"https://doi.org/10.1515/9783110592566-002","url":null,"abstract":": EMG signals in their raw form are very rich in information, but in order to be valuable in the process of myopathy’s diagnostic, they have first to be amplified then analog to digital converted and filtered. In this paper we investigate the possibilities to realize an EMG measurement system with low cost hardware components and improve the performance of the implementation by signal processing. The measurement system has a minimal design consisting of an amplifier interface conform to typical myopathy data bases and an Arduino-based acquisition system. When electrodes are placed on the skin in the right position, the developed device generates signal form and values, which are similar to those downloaded from EMG database. For data acquisition, signal analysis and classification, an intelligent LabView based data processing software was implemented, which uses also a clinical standard database for normal and myopathic EMG signals. For classification, significant signal features were selected, which are: the Shannon entropy, variance, mean absolute value and signal positive peak amplitude. The investigation shows, that these features are sufficient to discriminate between normal subjects and patients with myopathy. A PCA guided K-means clustering classifier was established and a classification accuracy of 91.7 %.","PeriodicalId":438065,"journal":{"name":"Sensors, Circuits and Instrumentation Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115995439","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Characterization and Optimizing the Efficiency of Electrostatic Energy Harvesters 静电能量收集器的特性及效率优化
Sensors, Circuits and Instrumentation Systems Pub Date : 2019-11-05 DOI: 10.1515/9783110592566-003
B. Bieske, Gerrit Kropp, Alexander Rolapp
{"title":"Characterization and Optimizing the Efficiency of Electrostatic Energy Harvesters","authors":"B. Bieske, Gerrit Kropp, Alexander Rolapp","doi":"10.1515/9783110592566-003","DOIUrl":"https://doi.org/10.1515/9783110592566-003","url":null,"abstract":"","PeriodicalId":438065,"journal":{"name":"Sensors, Circuits and Instrumentation Systems","volume":"141 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131617326","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Frontmatter
Sensors, Circuits and Instrumentation Systems Pub Date : 2019-11-05 DOI: 10.1515/9783110592566-fm
{"title":"Frontmatter","authors":"","doi":"10.1515/9783110592566-fm","DOIUrl":"https://doi.org/10.1515/9783110592566-fm","url":null,"abstract":"","PeriodicalId":438065,"journal":{"name":"Sensors, Circuits and Instrumentation Systems","volume":"289 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130020428","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Obstructive Sleep Apnea treatment Methods: A Comparative Study 阻塞性睡眠呼吸暂停治疗方法的比较研究
Sensors, Circuits and Instrumentation Systems Pub Date : 2019-11-05 DOI: 10.1515/9783110592566-005
G. B. Salah, K. Abbes, C. Abdelmoula, M. Masmoudi
{"title":"Obstructive Sleep Apnea treatment Methods: A Comparative Study","authors":"G. B. Salah, K. Abbes, C. Abdelmoula, M. Masmoudi","doi":"10.1515/9783110592566-005","DOIUrl":"https://doi.org/10.1515/9783110592566-005","url":null,"abstract":": This paper deals with Obstructive Sleep Apnea (OSA) which is a common disease characterized by partial or complete interruption of airflow during sleep owing to upper airway occlusion. Untreated OSA contributes to serious comorbidities; thus they are promising invasive and non-invasive treatments. Continuous Positive Airway Pressure (CPAP) is the most common and effective treatment for OSA, however it was rejected by patients after a short period of time because of its discomfort. Therefore, an alternative therapy for this population was required. Functional electrical stimulation FES of Hypoglossal nerve (HGN) has been investigated by multiple groups. Here we have compared between the mechanisms and clinical studies of published implants. A new method for detecting the onset of OSA based on esophageal pressure Pes parameter was demonstrated (threshold − 13 . 5 cm H 2 O ). According to the stimulation of HGN, it necessitated values range between 33–38 Hz for decline pharyngeal narrowing. respiratory cycle. These Stimulation pulses were sent to the HGN through molded silicone rubber electrode cuff which prohib-ited unwanted current spread. The electrode cuff was positioned unilaterally on a peripheral branch of HGN that innervated the genioglossus muscle and connected via a stimulation lead with the programmable IPG. The investigators used an external pro-gramming device in order to adjust stimulation parameters (stimulation amplitude, pulse width, stimulation frequency) and then defining the optimal stimulus param-86","PeriodicalId":438065,"journal":{"name":"Sensors, Circuits and Instrumentation Systems","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133379885","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Wideband Power Amplifier with Auto-Transformer Based Output Impedance Transformation Network 基于自耦输出阻抗变换网络的宽带功率放大器
Sensors, Circuits and Instrumentation Systems Pub Date : 2019-11-05 DOI: 10.1515/9783110592566-004
E. Sobotta, R. Wolf, F. Ellinger
{"title":"Wideband Power Amplifier with Auto-Transformer Based Output Impedance Transformation Network","authors":"E. Sobotta, R. Wolf, F. Ellinger","doi":"10.1515/9783110592566-004","DOIUrl":"https://doi.org/10.1515/9783110592566-004","url":null,"abstract":"","PeriodicalId":438065,"journal":{"name":"Sensors, Circuits and Instrumentation Systems","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127356164","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书